Harsh Environment Straight-Blade Plugs, Sockets, and Receptacles
Rated NEMA 6P, 13, IP66, and IP69K when mated, connectors withstand oil/coolant spraying; temporary submersion; high-pressure, high-temperature washdowns; and are corrosion resistant so they can be used in marine environments.
Plugs have a multiple-ring seal to keep out liquid when mated. They have a locking ring that screws together with sockets and receptacles so connections remain secure in high-vibration applications such as oil drilling and mining operations.
Sockets and receptacles have an attached cover that creates a watertight seal when not in use.
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.





NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Features | Environmental Rating | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 000000 |
5-20 | 125V AC | 20A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 00000 |
6-15 | 250V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 00000 |
6-20 | 250V AC | 20A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 00000 |





NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Environmental Rating | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 0000000 |
5-20 | 125V AC | 20A | 2.4" | Screw Terminals | 0.38"-0.67" | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 000000 |
6-15 | 250V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 000000 |
6-20 | 250V AC | 20A | 2.4" | Screw Terminals | 0.38"-0.67" | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Black | 0000000 | 000000 |





Wire Lead | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Connection Type | Gauge | Lg. | Receptacle Terminal Location | Mounting Location | Environmental Rating | Color | Each | |
Grounded | |||||||||||
5-15 | 125V AC | 15A | Wire Leads | 12 | 6" | Back | Outlet Box | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Gray | 0000000 | 0000000 |
5-20 | 125V AC | 20A | Wire Leads | 12 | 6" | Back | Outlet Box | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Gray | 0000000 | 000000 |
6-15 | 250V AC | 15A | Wire Leads | 12 | 6" | Back | Outlet Box | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Gray | 0000000 | 000000 |
6-20 | 250V AC | 20A | Wire Leads | 12 | 6" | Back | Outlet Box | NEMA 6P, NEMA 13, IP66, IP67, IP68, IP69K | Gray | 0000000 | 000000 |
Harsh Environment IEC Connectors with Power Switch



Rated IP67, these connectors create a dust- and watertight seal where they fit into the housing of power supplies, appliances, and other electronic devices. Instead of hardwiring your devices, these connectors let you plug in a standard IEC power cord and turn the power on and off with a built-in switch. Wire these connectors using the quick-disconnect terminals; they slide together with matching terminals on your wiring for a secure hold that's also easy to pull apart to make repairs. The terminals are on the back of the connector, so the wiring stays inside your device.
To protect your devices, these connectors have a thermal circuit breaker that uses the excess heat when there’s overcurrent to trip the breaker and cut power. If there’s a short circuit, the breakers can safely stop up to a 2,000-Amp breakthrough current. These connectors also have Class I shock protection, so they’re insulated and have a protective ground.
These connectors meet UL 94 V-0, which means they self-extinguish within 10 seconds if they catch fire, and won’t spread the fire by dripping. They’re also UL and C-UL recognized components, and CE and ENEC marked, so they meet stringent safety standards.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Current, A | Voltage | Frequency, Hz | Voltage | Frequency, Hz | No. of Circuits Controlled | Switch Starting Position | Industry Designation | Ht. | Wd. | Temp. Range, °F | Environmental Rating | Each | |
Male Receptacles | ||||||||||||||
Screw On | ||||||||||||||
C14 | 10 | 250V AC | 60 | 250V AC | 50 | 2 | 2 Off (Normally Open) | DPST-NO | 2.32" | 1.35" | -10° to 140° | IP67 | 00000000 | 000000 |
C14 | 15 | 250V AC | 60 | 250V AC | 50 | 2 | 2 Off (Normally Open) | DPST-NO | 2.32" | 1.35" | -10° to 140° | IP67 | 00000000 | 00000 |
Harsh-Environment EMI Filtering IEC Connectors



Power electronics in damp environments while protecting them from electromagnetic interference. The filter on these connectors reduces electromagnetic interference, which could damage components and cause your electronics to behave erratically. These connectors pair with industry standard cords often found on electronic devices. Wire them using the quick-disconnect terminals, which slide together with matching terminals on your device for a secure fit that can still be pulled apart by hand and removed for repairs. The terminals are on the back of the connector, so the wiring stays inside your device.
Class I shock protection means these connectors have insulation and a protective ground. They meet UL 94 V-0, so they self-extinguish within 10 seconds if they catch fire and won’t spread the fire by dripping. They’re also UL and C-UL recognized components, CE and ENEC marked—they meet U.S., Canadian, and European safety standards. They are rated IP65 for protection from dust and rinsing.
When selecting a connector, make sure the current is at or slightly above the requirements of your device for the best EMI filtering performance. These connectors require fuses (sold separately) to prevent short circuits and circuit overloads from damaging your devices.
For technical drawings and 3-D models, click on a part number.
UL Rating | IEC Rating | For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
IEC Style | Current, A | Voltage | Frequency, Hz | Voltage | Frequency, Hz | No. of Fuses Required | Fuse Size | Ht. | Wd. | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Male Receptacles | ||||||||||||||
C14 | 1 | 250V AC | 60 | 250V AC | 50 | 2 | 5mm x 20mm | 1.27" | 1.15" | -10° to 185° | IP65 | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CE Marked, ENEC Marked | 00000000 | 000000 |
C14 | 2 | 250V AC | 60 | 250V AC | 50 | 2 | 5mm x 20mm | 1.27" | 1.15" | -10° to 185° | IP65 | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CE Marked, ENEC Marked | 00000000 | 00000 |
C14 | 4 | 250V AC | 60 | 250V AC | 50 | 2 | 5mm x 20mm | 1.27" | 1.15" | -10° to 185° | IP65 | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CE Marked, ENEC Marked | 00000000 | 00000 |
C14 | 6 | 250V AC | 60 | 250V AC | 50 | 2 | 5mm x 20mm | 1.27" | 1.15" | -10° to 185° | IP65 | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CE Marked, ENEC Marked | 00000000 | 00000 |
C14 | 8 | 250V AC | 60 | 250V AC | 50 | 2 | 5mm x 20mm | 1.27" | 1.15" | -10° to 185° | IP65 | UL Recognized Component, C-UL Recognized Component, UL 94 V-0, CE Marked, ENEC Marked | 00000000 | 00000 |
Harsh Environment Turn-Lock Connectors
Rated NEMA 6P, NEMA 13, IP66, and IP69K when mated, connectors withstand high-pressure, high-temperature washdowns, oil/coolant splashing, and are corrosion resistant so they can be used in marine environments. They require a quarter turn to mate.
Plugs have a multiple-ring seal to keep out liquid when mated. They have a locking ring that screws together with sockets and receptacles so connections remain secure in high-vibration applications such as oil drilling and mining operations.
Sockets and receptacles have an attached cover that creates a watertight seal when not mated.
For technical drawings and 3-D models, click on a part number.



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Features | Environment | Environmental Rating | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
L5-15 | 125V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Black | 0000000 | 000000 |
L6-15 | 250V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Black | 0000000 | 00000 |
L7-15 | 277V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Multiple-Ring Seal, Aluminum Locking Ring | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Black | 0000000 | 00000 |




NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Environment | Environmental Rating | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L5-15 | 125V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Black | 0000000 | 0000000 |
L6-15 | 250V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Black | 0000000 | 000000 |
L7-15 | 277V AC | 15A | 2.4" | Screw Terminals | 0.38"-0.67" | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Black | 0000000 | 000000 |




Wire Lead | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Connection Type | Gauge | Lg. | Receptacle Terminal Location | Mounting Location | Environment | Environmental Rating | Color | Each | |
Grounded | ||||||||||||
L5-15 | 125V AC | 15A | Wire Leads | 12 | 6" | Back | Outlet Box | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Gray | 0000000 | 0000000 |
L6-15 | 250V AC | 15A | Wire Leads | 12 | 6" | Back | Outlet Box | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Gray | 0000000 | 000000 |
L7-15 | 277V AC | 15A | Wire Leads | 12 | 6" | Back | Outlet Box | Corrosive, Oily, Washdown | NEMA 6P, NEMA 13, IP66, IP68, IP69K | Gray | 0000000 | 000000 |
Harsh-Environment Screw-Down Butt Splices




Join wires and cables in some of the dirtiest and wettest locations—from paper mills to marine environments—without special tools. With a nylon body and gasketed end caps, these splices are IP68 rated to seal out dust and water even if briefly submersed. To install, insert wire into either side, tighten the screws with a slotted screwdriver, and twist on the end caps to seal. They have multiple terminals, so you can repair, extend, and reconfigure cables with multiple wires.
For Number of Wires | For Wire Gauge | Lg. | Color | For Wire Type | For Wire Material | Insulation Material | Terminal Material | Max. Voltage | Max. Temp., °F | Each | |
4 | 18-14 | 3.417" | Black | Stranded | Aluminum, Copper | Nylon Plastic | Nickel-Plated Brass | 450V AC | 221° | 0000000 | 000000 |
8 | 26-18 | 2.83" | Black | Stranded | Aluminum, Copper | Nylon Plastic | Nickel-Plated Brass | 130V DC 130V AC | 185° | 0000000 | 00000 |
Submersible Insulation-Piercing Butt Splices


Pierce the insulation of wire without stripping it to make quick connections that are also sealed to keep out water. These splices have termination buttons on each end, so you can make independent connections on both sides. Since you connect each end independently, they’re often used as a disconnect point on equipment that you’ll be moving around. To install these splices, use a pair of pliers to press down on the button until it clicks.
On 2-wire splices, each button comes in one of three colors that correspond with wire gauge, making it easy to match your wire to the right connector.
4-wire splices have two entry points on both ends for twice as many independent connections as 2-wire splices.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | For Wire Type | Max. Insulation OD (For Wire Gauge) | Length | Color | Insulation | Insulation Material | Terminal Material | Maximum Voltage | Maximum Temperature, °F | Environmental Rating | Specifications Met | Each | |
2-Wire Inline Wire Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18-16 | Solid, Stranded | 0.13" (18-16) | 1.89" | Red | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 00000 |
16-14 × 18-16 | Solid, Stranded | 0.13" (16-14), 0.17" (18-16) | 1.89" | Blue and Red | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
14-12 × 18-16 | Solid, Stranded | 0.13" (14-12), 0.17" (18-16) | 1.89" | Yellow and Red | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
14-12 × 16-14 | Solid, Stranded | 0.15" (14-12), 0.17" (16-14) | 1.89" | Yellow and Blue | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
14-12 | Solid, Stranded | 0.17" (14-12) | 1.89" | Yellow | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP08 | UL Listed | 0000000 | 0000 |
4-Wire Inline Wire Connection | |||||||||||||
22-20 | Solid, Stranded | 0.11" (22-20) | 1.43" | Blue | Fully Insulated | Polycarbonate Plastic | Bronze | 600V AC 600V DC | 220° | IP05, IP07, IP08 | UL Listed | 0000000 | 0000 |
Locking Extension Cords for Harsh Environments



Keep power flowing in dirty areas with rubber-insulated cords that resist oil, water, and chemicals. A locking lever on the socket prevents your device from disconnecting. The socket also has a power-indicating light that illuminates when the cord has power.
For technical drawings and 3-D models, click on a part number.
Cord | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
25 ft. | ||||||||||
14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 000000 |
50 ft. | ||||||||||
14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 00000 |
100 ft. | ||||||||||
14 | 13 | 125V AC | With Power-Indicating Light | 0.36" | Rubber | SJEOW | UL Listed, ETL Listed | Blue with Orange Stripe | 0000000 | 000000 |
Extension Cords for Harsh Environments



The insulation resists water, oil, and chemicals, so these cords withstand dirty and greasy environments.
Cords with a power-indicating light have a light on the socket that illuminates when the cord has power.
Cords with TPE insulation stay flexible even in extreme temperatures as low as -90° F.
Cord | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Color | Wire Gauge | Current, A | Voltage | Power-Indicating Light | OD | Insulation Material | Industry Designation | Temp. Range, °F | Specifications Met | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | |||||||||||
25 ft. | |||||||||||
Black | 14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 000000 |
Black | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Blue with White Stripe | 14 | 15 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 00000 |
50 ft. | |||||||||||
Black | 14 | 15 | 125V AC | With Power-Indicating Light | 0.36" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Black | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 00000 |
Blue with White Stripe | 14 | 15 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 00000 |
100 ft. | |||||||||||
Black | 12 | 15 | 125V AC | With Power-Indicating Light | 0.42" | EPDM Rubber | SJOOW | -40° to 220° | ETL Listed, C-ETL Listed | 0000000 | 000000 |
Blue with White Stripe | 14 | 13 | 125V AC | With Power-Indicating Light | 0.37" | TPE Rubber | SJEOW | -90° to 220° | __ | 0000000 | 000000 |