About Heaters for Pipes and Tubes
Self-Regulating Heat Cable—Adjusts its heat output in response to surface as well as surrounding temperatures.
Constant-Wattage Heat Cable—Always puts out the designated amount of watts/ft., regardless of the surrounding temperature.
More
Self-Regulating Heaters for Pipes and Tubes



When the ambient temperature changes, these heaters automatically adjust the heat output along the length of their cable. Also known as self-regulating heat cable, they don’t require a separate temperature switch or controller. These heaters use their full wattage for more heat when surrounding temperatures are low and reduce their wattage when temperatures are high. Heat output can simultaneously vary at multiple points along a single cable. They’re often used to maintain liquid temperature and viscosity and provide freeze protection in pipe and tube systems. All are CSA certified for pipe freeze protection and are rated for outdoor use. Heaters can overlap without creating hot spots or risking burnout. A protective rubber cover provides corrosion resistance and durability.
Heaters with a plug are also CSA certified for roof and gutter de-icing applications. The plug has an indicator light that shows when the system has power.
Note: Only install these heaters in accessible locations; do not install them behind walls, underground, or in other difficult-to-access areas. Use fiberglass tape or heat-transfer putty to install them directly on surfaces that are free of dirt, grease, and rough edges. Do not use electrical tape, duct tape, metal bands, or wire. To prevent heat loss and protect heaters from moisture and corrosion, wrap them with fiberglass insulation.
Watt Density, W/ft. | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wattage, W | @ 40° F | @ 80° F | @ 100° F | Wd. | Thick. | Environment Temp. Range, °F | Cord Lg., ft. | Cable Cover Material | For Surface Material | For Use Outdoors | Current, A | Each | |
6 | 36 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 0.15 | 0000000 | 0000000 |
12 | 72 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 0.3 | 0000000 | 000000 |
18 | 108 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 0.45 | 0000000 | 000000 |
24 | 144 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 0.6 | 0000000 | 000000 |
Watt Density, W/ft. | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wattage, W | @ 40° F | @ 80° F | @ 100° F | Wd. | Thick. | Environment Temp. Range, °F | Cord Lg., ft. | Cable Cover Material | For Surface Material | For Use Outdoors | NEMA Style | Current, A | Each | |
6 | 36 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 0.3 | 0000000 | 0000000 |
12 | 72 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 0.6 | 0000000 | 000000 |
18 | 108 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 0.9 | 0000000 | 000000 |
24 | 144 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 1.2 | 0000000 | 000000 |
50 | 300 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 2.5 | 0000000 | 000000 |
75 | 450 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 3.75 | 0000000 | 000000 |
100 | 600 | 6 | 3 | 1.5 | 7/16" | 1/4" | -40° to 150° | 6 | Rubber | Metal, Plastic | Yes | 5-15 | 5 | 0000000 | 000000 |
Roof and Gutter Heat Cable



Before ice begins to form, install this constant-wattage heat cable on roofs and in gutters and downspouts to prevent damage caused by ice buildup. To prevent burnout, it must not be overlapped. Cable includes enough roof clips and downspout spacers for the length ordered.
Controller (sold separately) turns cable on when moisture is detected and temperature drops below 39° F; turns off when moisture is no longer detected. It includes a 6-ft. power cord with three-prong plug.
Extra clips and spacers are sold separately.
Number Included | |||||||||
---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wattage, W | Wattage Density, W/ft | Current, A | Roof Clips | Downspout Spacers | Plug Type | Cord Lg., ft. | Each | |
120V AC, Single Phase | |||||||||
30 | 150 | 5 | 1.3 | 19 | 16 | Three Prong | 6 | 0000000 | 000000 |
60 | 300 | 5 | 2.5 | 38 | 32 | Three Prong | 6 | 0000000 | 00000 |
80 | 400 | 5 | 3.3 | 57 | 48 | Three Prong | 6 | 0000000 | 00000 |
100 | 500 | 5 | 4.2 | 76 | 64 | Three Prong | 6 | 0000000 | 00000 |
120 | 600 | 5 | 5 | 76 | 64 | Three Prong | 6 | 0000000 | 00000 |
160 | 800 | 5 | 6.7 | 95 | 80 | Three Prong | 6 | 0000000 | 000000 |
200 | 1,000 | 5 | 8.3 | 133 | 112 | Three Prong | 6 | 0000000 | 000000 |
240 | 1,200 | 5 | 10 | 152 | 128 | Three Prong | 6 | 0000000 | 000000 |