About NEMA Straight-Blade Plugs, Connectors, and Receptacles
More
About NEMA Plugs, Sockets, and Receptacles
More
About Extension Cords
More
GFCI Straight-Blade Receptacles
Keep personnel safe from electric shock by adding ground fault protection. The housing is impact-resistant plastic.
Receptacles with internal shutters prevent the insertion of foreign objects and accidental contact with power. They fit standard GFCI wall plates (not included).
For technical drawings and 3-D models, click on a part number.
NEMA Style | Voltage | Current | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Choose a Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Back, Side | Outlet Box | Test Button | Wall Plate | UL Listed, C-UL Listed, Fed. Spec. W-C-596, NFPA 70, UL 498 | 0000000 | 000000 | |
5-20 | 125V AC | 20A | Back, Side | Outlet Box | Test Button | Wall Plate | UL Listed, C-UL Listed, Fed. Spec. W-C-596, NFPA 70, UL 498 | 0000000 | 00000 |
Wire Lead | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Gauge | Lg. | Receptacle Terminal Location | Mounting Location | Features | Specifications Met | Choose a Color | Each | |
Grounded | |||||||||||
5-15 | 125V AC | 15A | 12 | 6" | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 000000 | |
5-20 | 125V AC | 20A | 12 | 6" | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 00000 |
Weather-Resistant GFCI Straight-Blade Receptacles
Suitable for use outdoors, these receptacles can be used in wet and damp environments. They keep personnel safe from electric shock by adding ground fault protection. Internal shutters prevent the insertion of foreign objects and accidental contact with power. The housing is impact-resistant plastic.
For technical drawings and 3-D models, click on a part number.
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Choose a Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Test Button | Wall Plate | 0000000 | 000000 | |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Test Button | Wall Plate | 0000000 | 00000 |
AFCI/GFCI Straight-Blade Receptacles
Minimize the risk of electric shock and electrical fires with a single receptacle. Receptacles interrupt when an arc fault or ground fault is detected. All have internal shutters to prevent the insertion of foreign objects and accidental contact with power.
For technical drawings and 3-D models, click on a part number.
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | Wall Plate | UL Listed, UL 498, UL 94 V-2, CSA Certified, Fed. Spec. W-C-596 | White | 0000000 | 000000 |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | Wall Plate | UL Listed, UL 498, UL 94 V-2, CSA Certified, Fed. Spec. W-C-596 | White | 0000000 | 00000 |
GFCI Sure-Grip Straight-Blade Receptacles
Keep personnel safe from electric shock by adding ground fault protection. Also known as hospital-grade receptacles, these have an extra-tight fit when mated with plugs to remain secure in high-vibration environments.
For technical drawings and 3-D models, click on a part number.
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Choose a Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Green Dot, Power-Indicating Light, Test Button | Wall Plate | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 000000 | |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Green Dot, Power-Indicating Light, Test Button | Wall Plate | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 00000 |
Washdown Straight-Blade Connectors and Cords
All connectors have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. When mated, connectors meet NEMA 6P, NEMA 12, and either IP67 or IP69K.
Connectors that meet IP67 resist temporary submersion.
Receptacles with GFCI keep personnel safe from electric shock.
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.
GFCI DIN-Rail Mount Straight-Blade Receptacles
Keep personnel safe from electric shock by adding ground fault protection. Receptacles mount to DIN rail so you can bring power closer to where you need it. The housing is impact-resistant plastic.
For technical drawings and 3-D models, click on a part number.
NEMA Style | Voltage | Current | Ht. | Wd. | Dp. | Wire Connection Type | For Wire Gauge | Receptacle Terminal Location | For DIN Rail Ht., mm | Features | Mounting Box Color | Color | Each | |
Grounded | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | 5.625" | 3.3" | 2.5" | Screw Terminals | 16-12 | Side | 35 | Test Button | Gray | Gray | 0000000 | 0000000 |
5-20 | 125V AC | 20A | 5.625" | 3.3" | 2.5" | Screw Terminals | 16-12 | Side | 35 | Test Button | Gray | Gray | 0000000 | 000000 |
Washdown Turn-Lock Connectors and Cords
When mated, connectors meet NEMA 6P for protection against corrosion and washdowns. All have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Receptacles with GFCI keep personnel safe from electric shock.
For technical drawings and 3-D models, click on a part number.
Conduit | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Trade Size | Thread Type | Mounting Location | Color | Each | |
Grounded | ||||||||||
L5-20 | 125V AC | 20A | Screw Terminals | Back, Front, Side | 3/4 | NPT | Outlet Box | Yellow | 000000000 | 0000000 |
Conduit | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Trade Size | Thread Type | Mounting Location | Color | Each | |
Grounded | ||||||||||
L5-15 | 125V AC | 15A | Screw Terminals | Back, Front, Side | 3/4 | NPT | Outlet Box | Yellow | 000000000 | 0000000 |
Extension Cord GFCI Converters
Hardwire one of these converters to an extension cord to keep personnel safe from electric shock.
Converters with automatic GFCI reset immediately regain power after ground is established.
Converters with manual GFCI reset prevent unexpected start-up.
For Cable OD | Reset Type | Number of Outlets | Wire Gauge | Current, A | Voltage | Material | Specifications Met | Color | Each | |
Inline GFCI | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5/16"-7/16" | Manual | __ | __ | 20 | 125V AC | Polycarbonate Plastic | UL Listed, CSA Certified | Yellow | 0000000 | 000000 |
5/16"-7/16" | Manual | __ | __ | 20 | 240V AC | Polycarbonate Plastic | UL Listed | Yellow | 0000000 | 000000 |
5/16"-9/16" | Automatic | __ | __ | 20 | 120V AC | Polycarbonate Plastic | UL Listed, C-UL Listed | Black | 0000000 | 00000 |
Inline GFCI with NEMA 5-15 Plug | ||||||||||
5/16"-5/8" | Automatic | __ | 12 | 15 | 125V AC | Polycarbonate Plastic | UL Listed, C-UL Listed | Yellow | 0000000 | 00000 |
5/16"-5/8" | Manual | __ | 12 | 15 | 125V AC | Polycarbonate Plastic | UL Listed, C-UL Listed | Yellow | 0000000 | 00000 |
Inline GFCI with NEMA 5-15 Socket | ||||||||||
5/16"-5/8" | Manual | 3 | 12 | 15 | 125V AC | Polycarbonate Plastic | UL Listed, C-UL Listed | Yellow | 0000000 | 00000 |
90° Elbow NEMA 5-15 GFCI Plug | ||||||||||
5/16"-7/16" | Manual | __ | __ | 15 | 125V AC | Polycarbonate Plastic | UL Listed, CSA Certified | Yellow | 0000000 | 00000 |
5/16"-5/8" | Automatic | __ | __ | 15 | 125V AC | Polycarbonate Plastic | UL Listed, C-UL Listed | Black | 0000000 | 00000 |
Extension Cord ELCI Converters
Prevent electric shocks from extension cords connected to boats, RVs, and other large electrical systems. These ELCI (equipment leakage circuit interrupters) converters monitor the flow of current to and from an electrical system. If they detect an imbalance, they cut off the power. They’re similar to GFCI converters, but they monitor an entire system rather than one device. They also tolerate a higher level of imbalance before they trip. These converters have a manual reset to keep equipment from starting unexpectedly.
For Cable OD | Reset Type | Current, A | Voltage | Material | Specifications Met | Color | Each | |
Inline ECLI | ||||||||
---|---|---|---|---|---|---|---|---|
5/16"-7/16" | Manual | 20 | 120V AC/240V AC | Polycarbonate Plastic | UL Listed, CSA Certified | Black | 0000000 | 000000 |
GFCI Outlet Strips
Keep personnel safe from electric shock with ground fault protection.
90° elbow plugs fit flush against a wall outlet, so they fit behind machinery or in areas where space is tight.
Outlet strips with a circuit breaker prevent damage from current overload and short circuits.
Flip-down covers protect outlets from dust when not in use.
Outlet strips with a manual reset prevent equipment from starting up unexpectedly after ground is established. Strips with an automatic reset immediately regain power after ground is established.
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Reset Type | Specifications Met | Color | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 1/2" (2) | 6 | 15 | 125V AC | Test Button, Flip-Down Cover | Polycarbonate Plastic | GFCI | Manual | __ | Yellow | 0000000 | 000000 |
NEMA 5-15 Socket with 90° Elbow NEMA 5-15 Plug | ||||||||||||
4 | 1 1/2" (4) | 6 | 15 | 125V AC | Test Button, Flip-Down Cover | Polycarbonate Plastic | GFCI | Manual | UL Listed | Gray | 0000000 | 000000 |
6 | 1 1/4" (4) 1 3/4" (2) | 9 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 00000 |
8 | 1" (5) 2" (3) | 12 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 000000 |
8 | 1" (5) 2" (3) | 25 | 15 | 125V AC | Test Button, Lighted Power Switch | Steel | Circuit Breaker, GFCI | Manual | UL Listed | Yellow | 0000000 | 000000 |
NEMA 5-20 Socket with NEMA 5-20 Plug | ||||||||||||
4 | 1 1/2" (4) | 6 | 20 | 125V AC | Flip-Down Cover | Polycarbonate Plastic | GFCI | Automatic | UL Listed | Yellow | 0000000 | 000000 |
GFCI Outlet Splitters
Turn a single outlet into five outlets with ground fault protection to minimize the risk of electric shock. These splitters automatically reset to regain power after ground is established.
For technical drawings and 3-D models, click on a part number.
Reset Type | No. of Outlets | Current, A | Voltage | Features | Material | Protection Type | Specifications Met | Color | Each | |
NEMA 5-15 Plug × NEMA 5-15 Socket | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Automatic | 5 | 15 | 125V AC | Test Button | Plastic | GFCI | UL Listed, C-UL Listed | White | 0000000 | 000000 |
GFCI Outlet Adapters
Minimize the risk of electric shock by adding ground fault protection to standard outlets.
Automatic reset adapters automatically regain power after ground is established.
Manual reset adapters prevent unexpected equipment start-up.
For technical drawings and 3-D models, click on a part number.
Enclosure-Mount Aluminum Power and Data Outlet Boxes
Mount these boxes to the outside of an enclosure to access a programmable logic controller or other networked device without opening the enclosure. They’re rated NEMA 4 for protection against dust, corrosion, and washdowns. A clear flip-down cover and sealing gasket keep water out when not in use. Electrical connections for wiring receptacles are on the back.
Ethernet connections take Category 5E cords.
For technical drawings and 3-D models, click on a part number.
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Current, A | Voltage | Ethernet Connection Type | No. of Ethernet Connections | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Wire Connection Type | Each | |
2 | 15 | 120V AC | RJ45 | 1 | 3 1/2" | 5 1/8" | 1 5/8" | No | 4 | 1/4" | IP65, NEMA 4 | Screw Terminals | 000000 | 0000000 |
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Current, A | Voltage | Ethernet Connection Type | No. of Ethernet Connections | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Wire Connection Type | Each | |
2 | 15 | 120V AC | RJ45 | 1 | 3 1/2" | 5 1/8" | 1 5/8" | No | 4 | 1/4" | IP65, NEMA 4 | Screw Terminals | 000000 | 0000000 |
Mounting | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Current, A | Voltage | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Wire Connection Type | Each | |
2 | 15 | 120V AC | 3 1/2" | 5 1/8" | 1 5/8" | No | 4 | 1/4" | IP65, NEMA 4 | Screw Terminals | 000000 | 0000000 |