About NEMA Straight-Blade Plugs, Connectors, and Receptacles
More
About NEMA Plugs, Sockets, and Receptacles
More
GFCI Straight-Blade Receptacles
Keep personnel safe from electric shock by adding ground fault protection. The housing is impact-resistant plastic.
Receptacles with internal shutters prevent the insertion of foreign objects and accidental contact with power. They fit standard GFCI wall plates (not included).
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/716/7160k68p2-d01b-digital@halfx_636277336100000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
NEMA Style | Voltage | Current | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Choose a Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Back, Side | Outlet Box | Test Button | Wall Plate | UL Listed, C-UL Listed, Fed. Spec. W-C-596, NFPA 70, UL 498 | 0000000 | 000000 | |
5-20 | 125V AC | 20A | Back, Side | Outlet Box | Test Button | Wall Plate | UL Listed, C-UL Listed, Fed. Spec. W-C-596, NFPA 70, UL 498 | 0000000 | 00000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/716/7160k811p1-d01b-digital@halfx_636144938240000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
Wire Lead | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Gauge | Lg. | Receptacle Terminal Location | Mounting Location | Features | Specifications Met | Choose a Color | Each | |
Grounded | |||||||||||
5-15 | 125V AC | 15A | 12 | 6" | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 000000 | |
5-20 | 125V AC | 20A | 12 | 6" | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 00000 |
Weather-Resistant GFCI Straight-Blade Receptacles
Suitable for use outdoors, these receptacles can be used in wet and damp environments. They keep personnel safe from electric shock by adding ground fault protection. Internal shutters prevent the insertion of foreign objects and accidental contact with power. The housing is impact-resistant plastic.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/716/7160k211p2-d01b-digital@halfx_636277344000000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Choose a Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Test Button | Wall Plate | 0000000 | 000000 | |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Test Button | Wall Plate | 0000000 | 00000 |
AFCI Straight-Blade Receptacles
Reduce the likelihood of an electrical fire. Receptacles interrupt when an arc fault is detected. They have internal shutters to prevent the insertion of foreign objects and accidental contact with power. Install in a standard outlet box.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/136/1364n11p1-d01b-digital@halfx_636244208250000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Choose a Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | Wall Plate | UL Listed, CSA Certified, UL 94 V-2, UL 498 | 000000 | 000000 | |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | Wall Plate | UL Listed, CSA Certified, UL 94 V-2, UL 498 | 000000 | 00000 |
AFCI/GFCI Straight-Blade Receptacles
Minimize the risk of electric shock and electrical fires with a single receptacle. Receptacles interrupt when an arc fault or ground fault is detected. All have internal shutters to prevent the insertion of foreign objects and accidental contact with power.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/136/1364n14p1-d01b-digital@halfx_636244210840000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | Wall Plate | UL Listed, UL 498, UL 94 V-2, CSA Certified, Fed. Spec. W-C-596 | White | 0000000 | 000000 |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Internal Shutters, Power-Indicating Light, Test Button | Wall Plate | UL Listed, UL 498, UL 94 V-2, CSA Certified, Fed. Spec. W-C-596 | White | 0000000 | 00000 |
GFCI Sure-Grip Straight-Blade Receptacles
Keep personnel safe from electric shock by adding ground fault protection. Also known as hospital-grade receptacles, these have an extra-tight fit when mated with plugs to remain secure in high-vibration environments.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/716/7160k7p2-d01b-digital@halfx_636280387510000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Includes | Specifications Met | Choose a Color | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | Screw Terminals | Back, Side | Outlet Box | Green Dot, Power-Indicating Light, Test Button | Wall Plate | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 000000 | |
5-20 | 125V AC | 20A | Screw Terminals | Back, Side | Outlet Box | Green Dot, Power-Indicating Light, Test Button | Wall Plate | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498 | 0000000 | 00000 |
Washdown Straight-Blade Connectors and Cords
All connectors have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. When mated, connectors meet NEMA 6P, NEMA 12, and either IP67 or IP69K.
Connectors that meet IP67 resist temporary submersion.
Receptacles with GFCI keep personnel safe from electric shock.
Note: The current rating of your plug should not exceed that of your socket or receptacle.
For technical drawings and 3-D models, click on a part number.
GFCI DIN-Rail Mount Straight-Blade Receptacles
![](/prerenderstable/mvPRE/contents/gfx/imagecache/765/7656t12-@halfx_637345406557895541.png?ver=imagenotfound)
Keep personnel safe from electric shock by adding ground fault protection. Receptacles mount to DIN rail so you can bring power closer to where you need it. The housing is impact-resistant plastic.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569857-p9@halfx_637461453625368396.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i15/i156-7120k923--398999947011610399553-p9@halfx_637459747692175536.png?ver=imagenotfound)
NEMA Style | Voltage | Current | Ht. | Wd. | Dp. | Wire Connection Type | For Wire Gauge | Receptacle Terminal Location | For DIN Rail Ht., mm | Features | Mounting Box Color | Color | Each | |
Grounded | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5-15 | 125V AC | 15A | 5.625" | 3.3" | 2.5" | Screw Terminals | 16-12 | Side | 35 | Test Button | Gray | Gray | 0000000 | 0000000 |
5-20 | 125V AC | 20A | 5.625" | 3.3" | 2.5" | Screw Terminals | 16-12 | Side | 35 | Test Button | Gray | Gray | 0000000 | 000000 |
Washdown Turn-Lock Connectors and Cords
When mated, connectors meet NEMA 6P for protection against corrosion and washdowns. All have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Receptacles with GFCI keep personnel safe from electric shock.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/694/69435k682p1-d01b-digital@halfx_636222517020000000.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i12/i127-7162k32--3f3f96a4db91609950229-p9@halfx_637455254348804756.png?ver=imagenotfound)
Conduit | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Trade Size | Thread Type | Mounting Location | Color | Each | |
Grounded | ||||||||||
L5-15 | 125V AC | 15A | Screw Terminals | Back, Front, Side | 3/4 | NPT | Outlet Box | Yellow | 000000000 | 0000000 |
GFCI Outlet Strips
![](/prerenderstable/mvPRE/contents/gfx/imagecache/768/7683k85-@halfx_dblnh_1716471829.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/5-1/5-15plugl3-d01b-master1527171815-p9@halfx_636668201032438871.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/4x-/4x-i172-7196k41--152cd8cf7031610569822-p9@halfx_637461453628580807.png?ver=imagenotfound)
Keep personnel safe from electric shock with ground fault protection.
Flip-down covers protect outlets from dust when not in use.
Outlet strips with a manual reset prevent equipment from starting up unexpectedly after ground is established.
For technical drawings and 3-D models, click on a part number.
Total No. of Outlets | Outlet Ctr.-to-Ctr. (No.) | Cord Lg., ft. | Current, A | Voltage | Features | Material | Protection Type | Reset Type | Color | Each | |
NEMA 5-15 Socket with NEMA 5-15 Plug | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 1/2" (2) | 6 | 15 | 125V AC | Test Button, Flip-Down Cover | Polycarbonate Plastic | GFCI | Manual | Yellow | 0000000 | 000000 |
Enclosure-Mount Aluminum Power and Data Outlet Boxes
Mount these boxes to the outside of an enclosure to access a programmable logic controller or other networked device without opening the enclosure. They’re rated NEMA 4 for protection against dust, corrosion, and washdowns. A clear flip-down cover and sealing gasket keep water out when not in use. Electrical connections for wiring receptacles are on the back.
Ethernet connections take Category 5E cords.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8223t3_f8b969be-ad64-47fa-ab17-e1d20e707be0@halfx_1679054391.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8223t3p1-d01b-digital@halfx_636848783554362588.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i11/i115-7196k41-1610569232-p9@halfx_637461444407576551.png?ver=imagenotfound)
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Current, A | Voltage | Ethernet Connection Type | No. of Ethernet Connections | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Wire Connection Type | Each | |
2 | 15 | 120V AC | RJ45 | 1 | 3 1/2" | 5 1/8" | 1 5/8" | No | 4 | 1/4" | IP65, NEMA 4 | Screw Terminals | 000000 | 0000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8223t4_dd394354-5684-449c-8755-69b87d55b998@halfx_1678818186.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8223t4p1-d01b-digital@halfx_636848806891098114.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i11/i115-7196k41-1610569232-p9@halfx_637461444407576551.png?ver=imagenotfound)
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Current, A | Voltage | Ethernet Connection Type | No. of Ethernet Connections | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Wire Connection Type | Each | |
2 | 15 | 120V AC | RJ45 | 1 | 3 1/2" | 5 1/8" | 1 5/8" | No | 4 | 1/4" | IP65, NEMA 4 | Screw Terminals | 000000 | 0000000 |
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8223t5_a8d05b5b-0e75-49c4-96b3-b31cb97c74dd@halfx_1678818277.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/822/8223t5p1-d01b-digital@halfx_636848719066238785.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i11/i115-7196k41-1610569232-p9@halfx_637461444407576551.png?ver=imagenotfound)
Mounting | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Outlets | Current, A | Voltage | Ht. | Wd. | Dp. | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Wire Connection Type | Each | |
2 | 15 | 120V AC | 3 1/2" | 5 1/8" | 1 5/8" | No | 4 | 1/4" | IP65, NEMA 4 | Screw Terminals | 000000 | 0000000 |
Ready-to-Use Steel Outlet Boxes
These boxes come ready to use with receptacles and/or light switches installed. Use the included plug-in connectors with wire leads to connect the receptacles and/or light switches. See information about NEMA straight-blade receptacles.
Outlet boxes with GFCIs (ground fault circuit interrupters) keep personnel safe from electric shock by adding ground fault protection.
For technical drawings and 3-D models, click on a part number.
![](/prerenderstable/mvPRE/contents/gfx/imagecache/182/1826t458-@halfx_637269364183346486.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/182/1826t534-@halfx_637269373004044369.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i11/i115-7196k41-1610569232-p9@halfx_637461444407576551.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/i11/i115-7120k923-1610569246-p9@halfx_637461444508999904.png?ver=imagenotfound)
![](/prerenderstable/mvPRE/contents/gfx/imagecache/182/1826t1--2f74586f95b1662667882-p9@halfx_637982466890263830.png?ver=imagenotfound)
Wire Leads for Outlets | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Industry Designation | NEMA Style | Voltage | Current, A | No. of | Gauge | Industry Designation | Lg. | Ht. | Wd. | Dp. | No. of Knockouts | Knockout Trade Size | Material | Choose an Outlet Color | Each | |
With 2 Outlets | ||||||||||||||||
1 Gang | 5-15 | 125V AC | 15 | 3 | 12 | THHN | 6" | 4" | 2 1/8" | 1 7/8" | 10 | 1/2 | Zinc-Plated Steel | 00000000 | 000000 | |
1 Gang | 5-20 | 125V AC | 20 | 3 | 12 | THHN | 6" | 4" | 2 1/8" | 1 7/8" | 10 | 1/2 | Zinc-Plated Steel | 00000000 | 00000 | |
With 4 Outlets | ||||||||||||||||
2 Gang | 5-15 | 125V AC | 15 | 3 | 12 | THHN | 6" | 4" | 4" | 2 1/8" | 16 | 1/2, 3/4 | Zinc-Plated Steel | 0000000 | 000000 | |
2 Gang | 5-20 | 125V AC | 20 | 3 | 12 | THHN | 6" | 4" | 4" | 2 1/8" | 16 | 1/2, 3/4 | Zinc-Plated Steel | 00000000 | 000000 |
For Device Type | Each | |
NEMA Outlet, GFCI Outlet | 0000000 | 00000 |