About Selecting Temperature Sensors
More
Flow Sights for Food and Beverage
Made of FDA-listed materials for use with food and beverage, these sights have sanitary quick-clamp connections and an electropolished 316 stainless steel body for easy disassembly and cleaning. They meet USP (United States Pharmacopeia) Class IV standard for food applications. Sights let you visually confirm flow and inspect liquid color and clarity. Backlight the back window to increase the visibility of dark liquids.
For technical drawings and 3-D models, click on a part number.
For Tube OD | Temp. Range, °F | Window Lg. | End-to-End Lg. | Ht. | Max. Pressure | Direction of Flow | Specifications Met | Each | |
316 Stainless Steel Body | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/2" | -20° to 300° | 3/4" | 3" | 1/2" | 150 psi @ 265° F | Any Direction | FDA Compliant 21 CFR 177.2600, USP Class IV | 0000000 | 0000000 |
3/4" | -20° to 300° | 1 1/8" | 3 3/8" | 3/4" | 150 psi @ 265° F | Any Direction | FDA Compliant 21 CFR 177.2600, USP Class IV | 0000000 | 000000 |
1" | -20° to 300° | 1 1/8" | 3 1/2" | 1" | 120 psi @ 265° F | Any Direction | FDA Compliant 21 CFR 177.2600, USP Class IV | 0000000 | 000000 |
1 1/2" | -20° to 300° | 1 1/2" | 4 1/8" | 1 1/2" | 115 psi @ 265° F | Any Direction | FDA Compliant 21 CFR 177.2600, USP Class IV | 0000000 | 000000 |
2" | -20° to 300° | 1 7/8" | 4 3/4" | 2" | 100 psi @ 265° F | Any Direction | FDA Compliant 21 CFR 177.2600, USP Class IV | 0000000 | 000000 |
Sights for Quick-Clamp Sanitary Tube Fittings
Gasket, Quick-Clamp Fitting, And
Tube Fitting (All Sold Separately)
Monitor food, brewery, chemical, pharmaceutical, and biotech processing lines with these sights that attach to quick-clamp fittings for fast installation and easy removal for cleaning. All have a one-piece design, so there are no crevices where bacteria can grow. A
For superior strength and reliability, choose 2205 stainless steel sights. All have a glass window that’s melted around a high-strength ring, so they won’t shatter, leak, or lose their shape under high pressure, heat, chemicals, or impact. They withstand harsh cleaners and sanitizers for clean-in-place (CIP) and steam-in-place (SIP) applications. USP Class VI and TUV Rheinland Certified, these sights meet safety standards in the U.S. and Europe. They also meet DIN standards for glass materials used in sights, ASTM standards for materials used in boilers and pressure vessels, and ASME BPE design standards for bioprocessing equipment that ensure purity and safety.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | For Flange OD | Window Dia. | Max. Pressure | Min. | Max. | For Use With | Features | Specifications Met | Each | |
2205 Stainless Steel Ring with Glass Window | ||||||||||
1", 1 1/2" | 1.98" | 1" | 230 psi @ 70° F | -40° | 500° | Water, Hydraulic Fluid, Diesel Fuel, Acetic Acid, Air, Alcohol-Based Solvents, Beverage, Chemicals, Compressed Air, Food, Fuel Oil, Gasoline, Inert Gas, Ketone, Oil, Salt Water, Steam | One-Piece Construction | ASME BPE, ASTM A479, DIN 7079, DIN 7080, TUV Rheinland Certified, USP Class VI | 0000000 | 0000000 |
2" | 2.52" | 1 3/16" | 230 psi @ 70° F | -40° | 500° | Water, Hydraulic Fluid, Diesel Fuel, Acetic Acid, Air, Alcohol-Based Solvents, Beverage, Chemicals, Compressed Air, Food, Fuel Oil, Gasoline, Inert Gas, Ketone, Oil, Salt Water, Steam | One-Piece Construction | ASME BPE, ASTM A479, DIN 7079, DIN 7080, TUV Rheinland Certified, USP Class VI | 0000000 | 000000 |
3" | 3.58" | 1 1/2" | 150 psi @ 70° F | -40° | 500° | Water, Hydraulic Fluid, Diesel Fuel, Acetic Acid, Air, Alcohol-Based Solvents, Beverage, Chemicals, Compressed Air, Food, Fuel Oil, Gasoline, Inert Gas, Ketone, Oil, Salt Water, Steam | One-Piece Construction | ASME BPE, ASTM A479, DIN 7079, DIN 7080, TUV Rheinland Certified, USP Class VI | 0000000 | 000000 |
4" | 4.68" | 2 3/16" | 150 psi @ 70° F | -40° | 500° | Water, Hydraulic Fluid, Diesel Fuel, Acetic Acid, Air, Alcohol-Based Solvents, Beverage, Chemicals, Compressed Air, Food, Fuel Oil, Gasoline, Inert Gas, Ketone, Oil, Salt Water, Steam | One-Piece Construction | ASME BPE, ASTM A479, DIN 7079, DIN 7080, TUV Rheinland Certified, USP Class VI | 0000000 | 000000 |
Remote-Reading Panel-Mount Thermometers
Monitor the temperature of difficult-to-access system components from a distance. The probe is connected to a cable, so the dial can be mounted away from your system.
Thermometers that meet NSF/ANSI standards are for use in food processing and preparation areas.
Probe | Mtg. Holes | Material | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Cable Lg., ft. | Lg. | Dia. | Panel Cutout Dia. | Flange OD | Bolt Circle Dia. | No. of | Dia. | Housing | Probe | Temperature Range | Specifications Met | Each | |
Front Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 0.312" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 000000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 4" | 3/8" | 3" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 120° F/-40° to 50° C | NSF/ANSI 2 | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 0.312" | 3 1/2" | 3 1/2" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
2 1/2" | 4 | 2 1/2" | 3/8" | 2 5/8" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
Back Flange Mount | ||||||||||||||
2" | 4 | 2 1/2" | 0.314" | 3 1/2" | 3" | 2 5/8" | 3 | 5/32" | Stainless Steel | Tin-Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 2 15/16" | 2 9/16" | 3 | 9/64" | Stainless Steel | Nickel Plated Copper | -40° to 110° F/-40° to 43° C | NSF/ANSI 2 | 00000000 | 00000 |
2" | 4 | 2 1/2" | 3/8" | 2 1/16" | 3 1/2" | 3 3/16" | 3 | 5/32" | Stainless Steel | Nickel Plated Copper | 40° to 240° F/0° to 115° C | NSF/ANSI 2 | 00000000 | 00000 |
Bracket Mount | ||||||||||||||
2 1/2" | 4 | 2 1/2" | 3/8" | __ | __ | __ | 1 | 11/64" | Stainless Steel | Nickel Plated Copper | -40° to 60° F/-40° to 15° C | NSF/ANSI 2 | 00000000 | 00000 |
Quick-Response Food and Beverage Panel-Mount Thermometers
A resistance temperature detector (RTD) probe responds to temperature change faster than dial thermometers.
For technical drawings and 3-D models, click on a part number.
Probe | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | For RTD Probe Type | Cable Lg., ft. | Dia. | Lg. | Panel Cutout Dia. | AC Voltage | Electrical Connection | Response Time, sec. | Includes | Each | |
-40° to 250° F | 1 | ±2° F | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 0000000 |
-40° to 120° C | 1 | ±2° C | 1,000 ohms | 8 | 1/4" | 2 5/8" | 2 3/32" | 120 | Plug | 1 | Bracket Assembly | 000000000 | 000000 |
Food and Beverage Hand-Held Thermometers
For use in food-processing applications, this thermometer meets NSF/ANSI standards and includes a thermocouple probe with a pointed tip to pierce dense meats and frozen foods. The housing meets IP07 for protection from temporary submersion.
Probe | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Temperature Range | Resolution | Accuracy | No. of Probe Inputs | Response Time, sec. | Cable Lg., ft. | Lg. | Dia. | Environmental Rating | Specifications Met | Batteries Included | Each | |
For Use With Air, Beverage, Food, Liquids, Solids | ||||||||||||
-100° to 500° F/-73° to 260° C | 0.1, 1/0.1, 1 | ±0.9° F/±0.5° C | 1 | 1 | 3 | 4" | 3/16" | IP07 | CE Marked, NSF/ANSI 2 | Yes | 00000000 | 0000000 |
Stainless Steel Replacement Probe | 00000000 | Each | 0000000 |
Sanitary RTD Probes for Liquids and Gases
Designed for clean-in-place applications such as dairy processing and food-preparation areas, these 3-A certified RTDs have a sanitary quick-clamp connection for easy removal. Remove the cap on the head to wire the probe’s terminal block to your application.
For technical drawings and 3-D models, click on a part number.
Probe | Conduit Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Connection Type | Pipe Size | Thread Type | Gender | Overall Lg. | Each | |
316 Stainless Steel Probe with Plastic Head | |||||||||||||
For 1 1/2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 1.984" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 0000000 |
For 2" Tube OD | |||||||||||||
100 ohms | -325° to 400° | 4" | 1/4" | 2.516" | ±0.1% | 5 | Screw Terminal | 3/4 | NPT | Female | 11" | 0000000 | 000000 |
Sanitary RTD Probe Transmitters with Digital Display for Liquids and Gases
Check the temperature of liquids in hygienic applications such as food or pharmaceutical lines and tanks. Certified by 3-A to meet sanitary design standards, the parts of these probes that will touch liquid are highly polished to minimize spots where bacteria could grow. They're made of stainless steel, so they won't corrode from harsh cleaners and sanitizers. The housing is IP69K rated, meaning it withstands high-pressure, high-temperature washdowns that are common in hygienic cleaning practices. They have a flange that will connect to sanitary quick-clamp fittings (also known as tri-clamp fittings); they're easy to connect and remove from your line.
Program these probes with the touch screen, and select one of three colors as a visual alert for events in your process such as irregular or fluctuating temperatures. The head swivels 345° and the face rotates all the way around, so you can mount the sensor at any angle and still see the display. To trigger actions in your process line, connect these probes to remote displays, programmable logic controllers (PLCs), and other control equipment with the M12 plug. These probes meet DIN EN 60751, an industry standard for accuracy. They’re also CE marked, meaning they meet European Union safety standards.
For technical drawings and 3-D models, click on a part number.
Probe | Probe Transmitters | Cables with Socket | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Flange OD | Accuracy | Response Time, sec. | Plug Type | DC Voltage | Max. Pressure, psi | Output Current | Overall Lg. | Each | Each | ||
316L Stainless Steel Probe with 304 Stainless Steel Head (IP69K) | |||||||||||||||
For 1 1/2" Tube OD | |||||||||||||||
100 ohms | -55° to 480° | 2" | 5/16" | 1.988" | ±0.1% | 25 | 5-Pole Micro M12 | 8-35 | 580 | 4-20mA | 6 3/4" | 0000000 | 0000000 | 0000000 | 000000 |