About Drum Pumps
More
Drum Pumps for Fuel and Flammable Liquid
All of these pumps have bonding and grounding wires, while some also have an internal flame arrester, to pump fuel, cleaning solvents, and lacquer thinners.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Steel pumps work with fuels and flammable liquids, but not especially aggressive and corrosive chemicals.
Stainless steel pumps handle aggressive and corrosive liquids that steel pumps cannot.
Pumps for 5-gallon containers have a drum connector that fits Rieke flex spouts and two screw cap adapters: 1 3/4" and 2 1/8".
Repair kits include components such as extension tubes, gaskets, and pistons.
Intake | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Max. Temp. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Each | |
Steel | ||||||||||
4 | 5 | 110 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8") | 1/2" | 16" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 0000000 |
4 | 5 | 650 | Not Rated | 1 3/4", 2 1/4", 2 1/8", 2 7/8" | Drum Connector, Flex Spout Adapter, Two Screw Cap Adapters (1 3/4" & 2 1/8") | 1 1/8" | 15" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
8 | 15-55 | 650 | Not Rated | 2 NPT | Drum Connector | 9/16" | 16"-38" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
8 | 55 | 110 | Not Rated | 2 NPT | Drum Connector | 1/2" | 22" | Bonding and Grounding Wires, Internal Flame Arrester | 0000000 | 000000 |
316 Stainless Steel | ||||||||||
10 | 5-7 | 650 | 140° F | 2 5/8", 2" | Drum Connector | 1 1/2" | 18" | Bonding and Grounding Wires | 0000000 | 000000 |
20 | 30-55 | 650 | 140° F | 2" | Drum Connector | 1 1/2" | 37 1/2" | Bonding and Grounding Wires | 0000000 | 000000 |
Smooth-Flow Drum Pumps for Fuel
Rotate the handle to dispense a continuous flow of liquid. These pumps are rated for use with Class I and II flammable and combustible fuels.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with removable spout allow you to replace the spout with a 1" ID discharge tube for transfer applications.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Features | Each | |
12.8 | 15-55 | 319 | -15° | 150° | 2 NPT | Drum Connector | 1" | 20"-35" | 5/8" | 8 | Bonding and Grounding Wires, Nozzle Hanger, Strainer, Vacuum Breaker | 0000000 | 0000000 |
Temp. Range, °F | Intake | Discharge (Spout End) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Pipe Size | Thread Type | Gender | Features | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 3/4" | 22"-40" | 3/4 | NPT | Male | Drip Pan, Internal Flame Arrester, Strainer | 0000000 | 0000000 |
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Features | Each | |
11 | 55 | 420 | Not Rated | 300° | 2 NPT | Drum Connector | 3/4" | 22"-40" | 3/4" | 8 | Internal Flame Arrester, Nozzle Hanger, Strainer, Vacuum Breaker | 0000000 | 0000000 |
Quick-Dispensing Drum Pumps with Nozzle for Fuel
These pumps have a 3/4" ID discharge hose for transfer applications and a vacuum breaker that drains the hose to prevent siphoning. A lever handle delivers fluid on both the forward and backward strokes for faster dispensing than other drum pumps. The handle can be mounted with the knob above or below the pump body. Lock the handle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Repair kits include a gasket, a piston ring, O-rings, and valves.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Hose ID | Hose Lg., ft. | Max. Shackle Dia. | Each | |
32 | 55 | 410 | Not Rated | 70° | 2 NPT | Drum Connector, Vacuum Breaker | 1 5/16" | 34" | 3/4" | 8 | 1/4" | 0000000 | 0000000 |
Quick-Dispensing Drum Pumps for Fuel
A lever handle delivers fluid on both the forward and backward strokes for faster dispensing than other drum pumps. The handle can be mounted with the knob above or below the pump body. Lock the handle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Repair kits include a gasket, a piston ring, O-rings, and valves.
Temp. Range, °F | Intake | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Discharge Location | For Discharge Hose ID | Spout Type | Max. Shackle Dia. | Each | |
32 | 55 | 410 | Not Rated | 70° | 2 NPT | Drum Connector | 1 5/16" | 34" | Spout End, Pump Body | 3/4" | Removable | 1/4" | 0000000 | 0000000 |
Nondrip Drum Pumps for Fuel and Flammable Liquid
Eliminate leaks and waste with a faucet-style nondrip nozzle that quickly starts and stops flow. Pressurize your container with a few pumps of the plunger handle, and use the one-touch nozzle to manage flow. Hold down the nozzle for intermittent dispensing, open the nozzle fully for continuous flow, and close the nozzle to stop flow entirely.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
NFPA approved pumps are rated for use with Class I and II flammable and combustible liquids such as fuels, alcohols, and acetone.
Remote tap kits extend your pump's reach for transferring liquid to tanks, mixers, and sprayers. They include a splash guard, a 6-ft. PVC tube, and hardware.
Pumps | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Remote Tap Kits | ||||||||||||
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Features | Flammability Rating | Each | Each | ||
4.5 | 2-55 | 270 | 35° | 110° | 2 NPT | Drum Connector | 5/8" | 40" | __ | __ | 0000000 | 0000000 | 0000000 | 0000000 |
4.5 | 2-55 | 270 | 35° | 110° | 2 NPT | Drum Connector | 5/8" | 40" | Bonding and Grounding Wires | NFPA 30 18.4.4.1 | 0000000 | 000000 | 000000 | 00 |
Easy-Stroke Drum Pumps with Nozzle for Fuel
A nozzle and hose allow you to dispense directly into your container. The lever handle maximizes output with each stroke for low-effort dispensing. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Add a metering nozzle to record flow rate for batches and total volume. The batch meter is resettable and registers up to 99.9 gallons. The meter for total volume is nonresettable and registers up to 99,999.99 gallons.
Repair kits include components such as gaskets, valve assemblies, and piston rings.
Temp. Range, °F | Intake | Discharge | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Tube OD | Tube Lg. | Hose OD | Hose Lg., ft. | Max. Shackle Dia. | Each | |
Pumps | ||||||||||||
26 | 15-55 | 319 | -15° | 150° | 2 NPT | 1" | 20"-35" | 5/8" | 8 | 1/4" | 0000000 | 0000000 |
Easy-Stroke Drum Pumps for Fuel
For low-effort dispensing, a lever handle maximizes output with each stroke. The handle delivers fluid on both the forward and backward strokes to quickly move drum contents. Lock the handle with a padlock (not included). Flow is reversible.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Repair kits include components such as gaskets, valve assemblies,and piston rings.
Drum Pumps for Diesel Exhaust Fluid
Made with polypropylene components, these pumps withstand highly corrosive diesel exhaust fluid (DEF) while preventing it from crystallizing. Intake tube is not included.
Temp. Range, °F | Discharge | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | For Intake Tube OD | Hose OD | Hose Lg., ft. | Nozzle Type | Each | |
11 | 55-275 | 1.5 | 35° | 110° | 2" | Drum Connector | 1" | 3/4" | 12 | Automatic Shut-Off | 000000 | 0000000 |
Drum Pumps for Water and Chemicals
Push the plunger to pump water, cleaners, and chemicals.
Styles A, B, and G are for thin liquids with a maximum viscosity of 700 or 750 centipoise.
Styles C-F are rated for liquids up to 2,500 centipoise. Style C are often used as hand pumps and do not come with a connector. To attach them to a container, select an optional connector.
Temp. Range, °F | Intake | Discharge | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
5 | 5-15 | 2,500 | 35° | 120° | 1/2" | 18" | 7/16" | 9/16" | 9" | 0000000 | 000000 |
Temp. Range, °F | Intake | Discharge | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size, mm | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
6 | 5 | 2,500 | 35° | 120° | 61 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 000000 |
6 | 5 | 2,500 | 35° | 120° | 63 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 00000 |
6 | 5 | 2,500 | 35° | 120° | 70 | Drum Connector | 1/2" | 14 1/2" | 7/16" | 9/16" | 36" | 0000000 | 00000 |
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Optional 2 5/8" Buttress Connectors | Replacement 2 NPT Connectors | |||||||||||||
Flow Rate, oz./stroke | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | Each | Each | |||
CSM Rubber Piston | |||||||||||||||||
28 | 55 | 2,500 | 35° | 120° | 2 NPT | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 36" | 0000000 | 0000000 | 0000000 | 000000 | 0000000 | 000000 |
28 | 55 | 2,500 | 35° | 120° | 2 NPT | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 72" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
28 | 55 | 2,500 | 35° | 120° | 2" | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 36" | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
28 | 55 | 2,500 | 35° | 120° | 2" | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 72" | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
Viton® Fluoroelastomer Rubber Piston | |||||||||||||||||
28 | 55 | 2,500 | 35° | 120° | 2 NPT | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 36" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
28 | 55 | 2,500 | 35° | 120° | 2 NPT | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 72" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
28 | 55 | 2,500 | 35° | 120° | 2" | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 36" | 0000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
28 | 55 | 2,500 | 35° | 120° | 2" | Drum Connector | 1 1/2" | 38" | 1 1/4" | 1 1/2" | 72" | 00000000 | 000000 | 0000000 | 00000 | 0000000 | 00000 |
Air-Powered Drum Pumps with Sanitary
Quick-Clamp Fittings for Food and Beverage
Made for use with food, water, and beverage, these pumps have a sanitary quick-clamp discharge connection for easy cleaning. Wetted parts are FDA compliant. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube Connection Type | For Tube OD | Specifications Met | Each | |
2.5 | 55 | 25,000 | 35° | 180° | 100 | 6 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 2" | 37 1/2" | Quick Clamp | 1" | FDA Compliant 21 CFR 177.1520; FDA Compliant 21 CFR 177.1550; FDA Compliant 21 CFR 177.2600 | 000000 | 000000000 |
Air-Powered Drum Pumps for Water, Oil, Coolants, and Chemicals
These pumps have a nonsparking air-powered motor for applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump. They're often used with ammonia, etching and cleaning solutions, and other caustics.
Temp. Range, °F | Air Connection | Intake | Discharge (Pump Body) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
14 | 55 | 1,500 | -30° | 300° | 40-80 | 27 | 2 NPT | Drum Connector | 1/8 | Female | NPT | 1 1/2" | 39" | 3/4 | Female | NPT | 00000000 | 0000000 |
Air-Powered Drum Pumps for Flammable Liquid
These pumps have a motor that is rated for IEC Zone 1, Groups IIB and IIA; and IEC Zone 21, Groups IIIC, IIIB, and IIIA hazardous locations with flammable gases and vapors, so they can be used with liquids such as acetone, ethanol, methyl ethyl ketone (MEK), xylene, and mineral spirits. Motor is nonsparking for use in applications where electricity is unavailable or dangerous. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Each | |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 000000000 |
26 | 55 | 1,100 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 39" | Barbed | 1" | 0000000 | 00000000 |
53 | 55 | 1,000 | -40° | 210° | 44-87 | 53 | 2 NPT | Drum Connector | 3/8 | Female | NPT | 1 5/8" | 47" | Barbed | 1" | 0000000 | 00000000 |
High-Pressure Air-Powered Drum Pumps for Fuel and Flammable Liquid
Use these pumps with fuel and flammable liquids, such as acetone, ethanol, and gasoline. They handle nearly twice the amount of pressure as other air-powered drum pumps to move high-viscosity liquids. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Temp. Range, °F | Air Connection | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure Range, psi | Air Consumption, cfm | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | Tube OD | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
4 | 55 | 7,500 | 40° | 200° | 0-150 | 10 | 2 NPT | Drum Connector | 1/4 | Female | NPT | 2 1/8" | 33 11/16" | 3/4 | Female | NPT | 0000000 | 000000000 |
Stainless Steel Extended-Life Air-Powered Drum Pumps for Chemicals
A stainless steel construction allows these pumps to be used with aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Repair kits include balls, O-rings, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
28 | 55 | 8,000 | 40° | 210° | 100 | 40 | 2 NPT | 1/4 | Female | NPT | 3/4 | Female | NPT | 39" | 3/4 | Female | NPT | 0000000 | 000000000 |
Repair Kit | 00000000 | Each | 0000000 |
Aluminum Extended-Life Air-Powered Drum Pumps for Fuel
Pump fuel such as gasoline, kerosene, and diesel fuel. Also known as diaphragm pumps, these pumps have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Repair kits include balls, O-rings, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
28 | 55 | 8,000 | 40° | 210° | 100 | 40 | 2 NPT | 1/4 | Female | NPT | 3/4 | Female | NPT | 39" | 3/4 | Female | NPT | 0000000 | 000000000 |
Repair Kit | 00000000 | Each | 0000000 |
PVDF Extended-Life Air-Powered Drum Pumps for Chemicals
A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
Repair kits include O-rings, valves, and diaphragms.
Temp. Range, °F | Air Connection | Intake | Discharge | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Air Pressure, psi | Air Consumption, cfm | For Drum Opening Size | Pipe Size | Gender | Thread Type | Pipe Size | Gender | Thread Type | Tube Lg. | Pipe Size | Gender | Thread Type | Each | |
13 | 55 | 3,000 | 40° | 210° | 100 | 12 | 2 NPT | 1/4 | Female | NPT | 1/2 | Female | NPT | 36" | 1/2 | Female | NPT | 0000000 | 000000000 |
Repair Kit | 00000000 | Each | 0000000 |
Foot-Operated Drum Pumps for Water and Oil
The foot pedal allows hands-free operation. These pumps have a telescoping intake tube that works with containers of different heights.
Temp. Range, °F | Intake | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Each | |
6 | 55 | 500 | 35° | 100° | 1 1/8"-2 3/4" | Drum Connector | 1/2" | 19"-35" | 0000000 | 0000000 |
Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals
Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Environmental Rating | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||
316 Stainless Steel Housing | ||||||||||||||||
18 | 15 | 55 | 1,000 | Not Rated | 175° | 1 1/3 hp | 9.1 | 2 NPT | 1 1/2" | 39" | 1" | 1 1/4" | 72" | NEC Class I Divisions 1, 2 Group D IP55 | 0000000 | 000000000 |
Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
Pumps | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Maintenance Parts | |||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Thermal Protection | Each | ||
120V AC, Single Phase | ||||||||||||||||
Hardwire | ||||||||||||||||
48.5 | 14 | 55 | 300 | -40° | 210° | 1/2 hp | 5.3 | 41 mm | 1 5/8" | 39" | Barbed | 1" | With Thermal Overload Protection | 00000000 | 000000000 | 00000000 |
Electric Drum Pumps with Nozzle for Fuel
Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Style A pumps have a circuit breaker to prevent overload. Pumps with automatic shut-off nozzle turn off when the tank is full.
Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation. Pedestal kit converts your pump from a drum mount to a pedestal mount.
Temp. Range, °F | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Tube OD | Tube Lg. | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 4.8 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Automatic Shut-Off | Hardwire | 0000000 | 0000000 |
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 5.5 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Manual Shut-Off | Hardwire | 0000000 | 000000 |
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
20 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 000000000 |
Battery-Operated Drum Pumps with Nozzle for Fuel
Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record total volume up to 99,999.9 gallons.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | ID | Lg., ft. | Nozzle Type | Each | |
12V DC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Manual Shut-Off, Lockable | 0000000 | 0000000 |
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Metering, Manual Shut-Off | 0000000 | 000000 |
Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel
These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with automatic shut-off nozzle turn off when the tank is full.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | ID | Lg., ft. | Nozzle Type | Max. Shackle Dia. | Thermal Protection | Each | |
12V DC | |||||||||||||||||||
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Automatic Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000000 |
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Manual Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000 |