UL Class T Fuses for Extra-Tight Spaces
Smaller than UL Class J fuses, these fast-acting fuses can be used in extra-tight spaces such as meters, uninterruptible power supplies, and variable-speed drives. They open circuits quickly when surges are detected. Use with Fuse Blocks for UL Class T Fuses.
Breakthrough current, also known as interrupt current, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | Each | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Specifications Met | 1-9 | 10-Up | |
Manufacturer Equivalent: A3T, JJN, JLLN | ||||||||||
3 | 300V AC | 200,000 A @ 300 V AC | 7/8" | 7/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 000000 | 000000 |
10 | 300V AC | 200,000 A @ 300 V AC | 7/8" | 7/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
15 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 7/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
20 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 7/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
30 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 7/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
35 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 9/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
40 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 9/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
50 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 9/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
60 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 7/8" | 9/16" | 1 | Ferrule | UL Listed, CSA Certified, CE Marked | 000000000 | 00000 | 00000 |
80 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 2 3/16" | 3/4" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 | 00000 |
100 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 2 3/16" | 3/4" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 | 00000 |
150 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 2 7/16" | 7/8" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 | 00000 |
200 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 2 7/16" | 7/8" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 | 00000 |
300 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 2 3/4" | 1" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 00000000 | 000000 | 000000 |
400 | 300V AC/160V DC | 20,000 A @ 160 V DC 200,000 A @ 300 V AC | 2 3/4" | 1" | 1 | Knife Blade | UL Listed, CSA Certified, CE Marked | 00000000 | 000000 | 00000 |
Fast-Acting Inline Fuses
Also known as LGR fuses, these fuses protect fluorescent light fixtures. They open circuits quickly when surges are detected. You'll need both a fuse and a fuse holder (not included) to add an inline fuse to an existing circuit. Fuses have a built-in cap that securely connects to the fuse holder.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | Number of Elements | Specifications Met | Each | |
Manufacturer Equivalent: GLR, LGR, SLR | ||||||||
1 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 00000 |
1 1/2 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
2 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
3 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
4 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
5 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
10 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
Time-Delay Inline Fuses
Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges. They are designed to handle high inrush loads from ballast transformers in fluorescent lighting systems. You'll need both a fuse and a fuse holder (not included) to add an inline fuse to an existing circuit. Fuses have a built-in cap that securely connects to the fuse holder. Also known as LMF fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Specifications Met | Each | |
Manufacturer Equivalent: LMF, SMF | ||||||||
1/2 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 00000 |
1 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
1 6/10 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
2 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
3 2/10 | 300V AC | 10,000 A @ 300 V AC | 1.82" | 0.61" | 1 | UL Listed, CSA Certified | 000000000 | 0000 |
Inline Fuse Holders
Add an inline fuse to an existing circuit. This holder is for use with both time-delay and fast-acting inline fuses.
Panel-mount clips (sold separately) are required to mount holder into a panel knock-out.
For technical drawings and 3-D models, click on a part number.
Fuse Blocks for UL Class Fuses
For technical drawings and 3-D models, click on a part number.
For Fuse | |||||||
---|---|---|---|---|---|---|---|
For No. of Fuses | UL Class | Current, A | Voltage | Wire Connection Type | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: A3T, JJN, JLLN | |||||||
2 | T | 1/2-30 | 300V AC | Box-Lug Terminals | UL Listed, CSA Certified, CE Marked | 00000000 | 000000 |
2 | T | 31-60 | 300V AC | Box-Lug Terminals | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 |
3 | T | 1/2-30 | 300V AC | Box-Lug Terminals | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 |
3 | T | 31-60 | 300V AC | Box-Lug Terminals | UL Listed, CSA Certified, CE Marked | 00000000 | 00000 |
3 | T | 61-100 | 300V AC | Box-Lug Terminals | UL Listed, CSA Certified, CE Marked | 00000000 | 000000 |
Fuse Blocks for Glass-Tube and Ceramic-Tube Fuses
Quick-Disconnect
Terminal
Quick-Disconnect
Terminals
Quick-Disconnect
Terminals
These fuse blocks fit ¼" glass- and ceramic-tube fuses. All have spring clips that hold fuses securely, yet allow for quick changes.
For Fuse | Quick-Disconnect Tab | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | Trade Size | Current, A | Overall Dia. | Overall Lg. | Voltage | Wire Connection Type | Wd. | Shape | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: 312, 313, 314, 322, 326, 505, ABC, AGC, GAB, GBB, GDL, GGC, GSA, MDA, MDL | |||||||||||
1 | 3AB, 3AG | 1/10-20 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.187" | 45° Elbow | UL Recognized Component | 0000000 | 00000 |
1 | 3AB, 3AG | 1/10-30 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.25" | 45° Elbow | UL Recognized Component | 0000000 | 0000 |
2 | 3AB, 3AG | 1/10-20 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.187" | 45° Elbow | UL Recognized Component | 0000000 | 0000 |
2 | 3AB, 3AG | 1/10-30 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.25" | 45° Elbow | UL Recognized Component | 0000000 | 0000 |
10 | 3AB, 3AG | 1/10-20 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.187" | 40° Elbow | UL Recognized Component | 000000 | 00000 |
10 | 3AB, 3AG | 1/10-20 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.187" | Straight | UL Recognized Component | 000000 | 00000 |
10 | 3AB, 3AG | 1/10-20 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.25" | 40° Elbow | UL Recognized Component | 000000 | 00000 |
10 | 3AB, 3AG | 1/10-20 | 1/4" | 1 1/4" | 300V AC | Quick-Disconnect Terminals | 0.25" | Straight | UL Recognized Component | 000000 | 00000 |
10 | 3AB, 3AG | 1/10-30 | 1/4" | 1 1/4" | 300V AC | Screw Terminals | __ | __ | UL Recognized Component | 000000 | 00000 |
Panel-Mount Fuse Holders for Glass-Tube and Ceramic-Tube Fuses
with 90° Elbow
Quick-Disconnect Terminal
Insert glass- and ceramic-tube fuses into holders and twist the cover closed.
For technical drawings and 3-D models, click on a part number.
For Fuse | Quick-Disconnect Tab | For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | Trade Size | Current, A | Overall Dia. | Overall Lg. | Voltage | Wd. | Shape | Ht. | Wd. | For Panel Thick. | Lg. | Material | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: 225, 229, C519, C520, SMG, STG | |||||||||||||||
1 | 2AG | 3/8-10 | 0.18" | 0.57" | 300V AC | 0.11" | 90° Elbow | 0.44" | 0.39" | 0.25" | 0.93" | Plastic | UL Recognized Component | 0000000 | 000000 |