Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Protection Type | Specifications Met | Each | |
Manufacturer Equivalent: DMM-B, FLU, FSM | ||||||||||
44/100 | 1,000V AC/1,000V DC | 10,000 A @ 1,000 V AC 10,000 A @ 1,000 V DC | 1 3/8" | 13/32" | 1 | Ferrule | Fast Acting | UL Recognized Component | 000000 | 000000 |
11 | 1,000V AC/1,000V DC | 20,000 A @ 1,000 V AC 20,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Recognized Component | 000000 | 00000 |
15 | 1,000V AC/1,000V DC | 20,000 A @ 1,000 V AC 20,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Recognized Component | 000000 | 00000 |
1,000V DC Fuses
Developed for the solar industry, these fuses meet the needs of high-voltage DC applications. They can withstand the cycling conditions and environment associated with outdoor installations. Designed for use with fuse blocks for 1,000V DC fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Breakthrough Current | Lg. | Dia. | No. of Elements | Cartridge Fuse Style | Protection Type | Specifications Met | Each | |
Manufacturer Equivalent: DCT, PV | ||||||||||
1 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 000000 |
2 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
3 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
4 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
5 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
6 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
8 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
10 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
12 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
15 | 1,000V DC | 10,000 A @ 1,000 V DC | 1 1/2" | 13/32" | 1 | Ferrule | Fast Acting | UL Listed, EN 63000, IEC 63000 | 00000000 | 00000 |
DIN-Rail Mount Fuse Blocks for 1,000V DC Fast-Acting Fuses
Designed for the solar industry, these fuse blocks can handle the requirements of high-voltage DC applications. The covered terminals prevent contact with live electrical circuits.
For technical drawings and 3-D models, click on a part number.
For Fuse | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | Current, A | Overall Dia. | Overall Lg. | Voltage | Wire Connection Type | For DIN Rail Size, mm | Features | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: DCT, PV | ||||||||||
1 | 1-15 | 13/32" | 1 1/2" | 1,000V DC | Screw Terminals | 35 | Covered Terminals | EN 63000, IEC 63000, UL Recognized Component | 000000 | 000000 |
1 | 1-15 | 13/32" | 1 1/2" | 1,000V DC | Screw Terminals | 35 | Covered Terminals, Blown-Fuse Indicator | EN 63000, IEC 63000, UL Recognized Component | 000000 | 00000 |