Don’t see the fuse you need? Just tell us what you’re looking for and we’ll get it for you.
About Fuses
More
Fast-Acting Glass-Tube Fuses
These fuses open circuits quickly when surges are detected. The clear glass tube makes it easy to see when fuses open. Use them with electronics, control panels, and other sensitive components. Select them by their diameter. Designed for use with Fuse Blocks for Glass-Tube Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Pkg. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Fuse Trade Size | Current, A | Voltage | Breakthrough Current | Overall Lg. | No. of Elements | Blown Fuse Indicator | Specifications Met | Pkg. Qty. | 1-9 | 10-Up | |
Manufacturer Equivalent: 225, C520, SMG | |||||||||||
0.18" Overall Dia. | |||||||||||
2AG | 1/8 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 000000 | 000000 |
2AG | 1/4 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 00000 |
2AG | 3/8 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 00000 |
2AG | 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 3/4 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 1 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 1 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 2 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 3 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 3 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 0000 | 0000 |
2AG | 4 | 125V AC | 500 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 5 | 125V AC | 500 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 6 | 125V AC | 500 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 7 | 125V AC | 500 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 8 | 125V AC | 500 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 10 | 125V AC | 500 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component, CSA Certified | 5 | 0000000 | 00000 | 0000 |
Time-Delay Glass-Tube Fuses
Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges. The clear glass tube makes it easy to see when fuses open. Use them with electronics, control panels, and other sensitive components. Select these fuses by their diameters. Designed for use with Fuse Blocks for Glass-Tube Fuses.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Pkg. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Fuse Trade Size | Current, A | Voltage | Breakthrough Current | Overall Lg. | No. of Elements | Blown Fuse Indicator | Specifications Met | Pkg. Qty. | 1-9 | 10-Up | |
Manufacturer Equivalent: 229, C519, STG | |||||||||||
0.18" Overall Dia. | |||||||||||
2AG | 1/4 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 000000 | 00000 |
2AG | 3/8 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 6/10 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 3/4 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 1 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 1 1/4 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 1 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 2 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 3 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 3 1/2 | 250V AC | 10,000 A @ 125 V AC | 0.57" | 1 | Yes | UL Listed, CSA Certified | 5 | 0000000 | 00000 | 0000 |
2AG | 4 | 125V AC | 400 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component | 5 | 0000000 | 00000 | 0000 |
2AG | 5 | 125V AC | 400 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component | 5 | 0000000 | 00000 | 0000 |
2AG | 6 | 125V AC | 400 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component | 5 | 0000000 | 00000 | 0000 |
2AG | 7 | 125V AC | 400 A @ 125 V AC | 0.57" | 1 | Yes | UL Recognized Component | 5 | 0000000 | 00000 | 0000 |
Panel-Mount Fuse Holders for Glass-Tube and Ceramic-Tube Fuses
with 90° Elbow
Quick-Disconnect Terminal
Insert glass- and ceramic-tube fuses into holders and twist the cover closed.
For technical drawings and 3-D models, click on a part number.
For Fuse | Quick-Disconnect Tab | For Panel Cutout | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For No. of Fuses | Trade Size | Current, A | Overall Dia. | Overall Lg. | Voltage | Wd. | Shape | Ht. | Wd. | For Panel Thick. | Lg. | Material | Specifications Met | Each | |
For Fuse Manufacturer Equivalent: 225, 229, C519, C520, SMG, STG | |||||||||||||||
1 | 2AG | 3/8-10 | 0.18" | 0.57" | 300V AC | 0.11" | 90° Elbow | 0.44" | 0.39" | 0.25" | 0.93" | Plastic | UL Recognized Component | 0000000 | 000000 |