How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Extended-Life Plastic Circulation Pumps for Chemicals
These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Pumps that cannot be sold to Canada are restricted due to energy efficiency regulations.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Maintenance Kits | Replacement Impellers | ||||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Intake (Gender) | Discharge (Gender) | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | Each | Each | |||
120V AC, 240V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
23 | __ | 20 | 10 | __ | __ | __ | 35 | __ | 1/4 | 2.07/4.14 | 1 (Female) | 1 (Female) | 14 3/8" | 5 1/8" | 7 7/8" | __ | 0000000 | 000000000 | 00000000 | 000000 | 00000000 | 0000000 |
26 | __ | 26 | 12 | __ | __ | __ | 35 | __ | 1/3 | 3.24/6.84 | 1 (Female) | 1 (Female) | 16 5/16" | 6 1/8" | 8 3/16" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
57 | 57 | 53 | 30 | 25 | __ | __ | 45 | __ | 1/2 | 1.1/2.2 | 1 1/2 (Female) | 1 1/2 (Female) | 18 3/8" | 8 7/8" | 11 5/16" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
90 | 90 | 84 | 74 | 61 | 49 | __ | 70 | __ | 1 | 1.5/3 | 1 1/2 (Female) | 1 1/2 (Female) | 18 7/8" | 6 5/16" | 10 1/8" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
120V AC, 208–240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 7.5/3.7-3.7 | 1 (Female) | 3/4 (Male) | 15 1/2" | 9" | 8 1/4" | __ | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 9.2/6.3-4.6 | 1 1/2 (Female) | 1 (Male) | 17 13/16" | 9 1/8" | 8 3/16" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
208–240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
30 | 31 | 26 | 20 | 7 | __ | __ | 41 | 5 | 1/3 | 0.6/1.3-1.2 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/4" | 7 3/8" | __ | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 1.7/1.7-0.8 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/8" | 7 3/16" | __ | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 1.1/3.3-2.2 | 1 1/2 (Female) | 1 (Male) | 16 9/16" | 9 1/8" | 7 3/8" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
82 | 82 | 82 | 81 | 80 | 71 | 61 | 85 | 5 | 2 | 2.4/4.9-4.8 | 2 (Male) | 1 1/2 (Male) | 20 11/16" | 10 3/8" | 10" | Canada | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
120 | 120 | 120 | 120 | 112 | 105 | 92 | 95 | 5 | 3 | 3.9/8-7.8 | 2 (Male) | 1 1/2 (Male) | 24 3/8" | 11 1/2" | 10 1/2" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
Circulation Pumps for Fuel and Flammable Liquid
Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 7.4/3.7 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 2.4-2.2/1.1 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
100 | __ | 78 | 48 | 10 | 64 | 150 | 264 | 1 | 2.8/1.4 | 1 1/2 | 1 | 15 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
15 | __ | 10 | 4 | __ | 46 | 150 | 264 | 1/3 | 4.8/2.4 | 3/4 | 1/2 | 15 1/2" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
100 | 78 | 64 | 48 | 10 | 64 | 150 | 264 | 1 | 12/6 | 1 1/2 | 1 | 17 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
115 | __ | 100 | 90 | 60 | 81 | 150 | 264 | 1 1/2 | 5-4.6/2.3 | 1 1/2 | 1 | 16 3/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
125 | 114 | 98 | 78 | 18 | 69 | 150 | 264 | 2 | 5.7-5.4/2.7 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
140 | __ | __ | 120 | 47 | 75 | 150 | 264 | 3 | 8.1-7.6/3.8 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Self-Priming Circulation Pumps without Motor for Oil
Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Intake (NPT) | Discharge (NPT) | Shaft | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Gender | Pipe Size | Gender | Pipe Size | Dia. | Lg. | Ctr.-to-Base Lg. | Ht. | Lg. | Wd. | Each | |
For 500 rpm-2,100 rpm Motor Speed | |||||||||||||||||
11.5 | 50 | 21 | Not Rated | 50° to 180° | 1/3 hp | Female | 1/2 | Female | 1/2 | 5/8" | 1 1/8" | 1 15/16" | 3 13/16" | 4 1/2" | 4 1/8" | 0000000 | 0000000 |
25 | 50 | 26 | Not Rated | 50° to 180° | 3/4 hp | Female | 1 | Female | 1 | 5/8" | 2 1/4" | 1 7/8" | 3 9/16" | 6 3/8" | 4 3/4" | 0000000 | 000000 |