Filter by
Fitting Connection
Maximum Flow
Body Material
Flow Measurement Unit
For Use With
Minimum Flow
Wetted Parts Material
Calibrated With
Flow Measurement Type
Maximum Temperature
Measures
Performance
REACH
RoHS
Component
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Total Number of Outputs
Bore Size
Digital Output Type
Electrical Connection
End-to-End Length
Field Recalibratable
Mounting Location
Build-Your-Own Flanged Pipe Flow Transmitters
![]() |
Components Sold Separately (Pipe Flanges Not Included) |
Install these transmitters between two flanges in a flanged pipe system to measure flow rate and send the data to a remote display or programmable logic controller (PLC). For easy cleaning and maintenance, you can slide the transmitter out from between the flanges. A complete transmitter consists of a flow transmitter, display, and mounting hardware kit (all components sold separately). Flowing liquid turns the turbine in the transmitter, while the easy-to-read display counts the number of turns to measure and transmit the flow. The display also shows total and batch flow volumes. Use these transmitters with clean, low-viscosity liquids to avoid clogging or other damage to the internal parts. Mount them inline with your pipe system. They’re accurate in any mounting orientation.
Also known as transducers, these transmitters help you monitor status or control equipment by converting measurements to a digital pulse that can be interpreted by receiving devices. Each pulse is a spike of voltage. The higher the flow, the more pulses they send. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the measurement range and output signal of the transmitter. Transmitters will only provide accurate readings within the rated measurement range.
The transmitters are calibrated with water but can be used with other liquids.
Flow Transmitters
![]() |
Flange | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Measurement Type | Pipe Size | Flow Range, gpm | Bore Size | OD | Type | For Flange ANSI Class | End-to-End Lg. | Accuracy | Max. Pressure @ Temp. | Temp. Range, ° F | Mounting Position | Field Recalibratable | Pulse Frequency per Volume, pulse per gal. | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
One Digital Pulse Output—2-Pin BNC Connection Plug | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
316/316L Stainless Steel Body with 316/316L Stainless Steel Fitting | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Turbine | 3 | 60 to 600 | 3" | 5" | Round | 150 | 4 1/4" | -1.0% to 1.0% | 285 psi @ 70° F | -150 to 350 | Any Angle | No | 50 | 0000000 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Mounting Hardware Kits
![]() |
For Pipe Size | For Flange ANSI Class | Includes | Each | |||
---|---|---|---|---|---|---|
3 | 150 | 4 Studs, 12 Nuts, 2 Gaskets, 2 Centering Rings | 0000000 | 0000000 | ||