    2 Products

    Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Variable Area Flow Measurement.

    Variable Area Flow

    Measurement

    Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
    A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    Variable Area Flow Measurement—Variable-area transmitters determine the flow rate by tracking where the liquid pushes the piston. They have two configurable outputs. One can be wired as an analog output or a digital switch. The other one can be wired as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. These transmitters are calibrated with water, glycol solutions, and coolants but can be recalibrated in the field for other liquids.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gph
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch Output—4-Pole Micro M12 Connection Plug
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Variable Area1 1/2 NPT Female60 to 3,0006 3/16"-5% to 5%362 psi @ 70° F14 to 212Fluoroelastomer18 to 30Any AngleYesIP65, IP6700000000000000
     

    High-Accuracy Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. High-Accuracy Flow and Temperature Transmitters.
    Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
    These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
    Flow Range
    Flow Measurement
    Type
    Pipe
    Connections
    Gallons per
    Minute, gpm
    Liters per
    Minute, L/min
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole Micro M12 Connection Plugs
     
    316 Stainless Steel/Plastic/Polybutylene Body with 316 Stainless Steel Fitting
    Magnetic Induction1 1/2 NPT Female1.3 to 79.35 to 3006 11/16"-0.8% to 0.8%225 psi @ 70° F0 to 17520 to 30Any AngleNoIP65, IP6700000000000000000
     