    3 Products

    Flow and Temperature Transmitters

    Image of Product. Back orientation. Flow Transmitters. Flow and Temperature Transmitters, Vortex Flow Measurement.

    Vortex Flow

    Measurement

    Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
    A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    Vortex Flow Measurement—Vortex transmitters determine the flow rate by measuring the size of the vortex created as liquid flows through them. They don’t have any moving parts that can break or get stuck. Use them only with liquids that are at least 95% water. They have one analog output for flow and another for temperature. The output for temperature can also be wired for IO Link.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    gph
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    Two 4-20 mA Analog Transmitter Outputs—4-Pole Micro M12 Connection Plugs
     
    316 Stainless Steel Body with 316 Stainless Steel Fitting
    Vortex1/2 NPT Female16 to 3174 11/16"-2% to 2%172 psi @ 70° F14 to 190Fluoroelastomer18 to 30Any AngleNoIP65, IP6700000000000000
    Vortex1/2 NPT Female32 to 6344 11/16"-2% to 2%172 psi @ 70° F14 to 190Fluoroelastomer18 to 30Any AngleNoIP65, IP670000000000000
    Vortex3/4 NPT Female80 to 1,5855 15/32"-2% to 2%172 psi @ 70° F14 to 190Fluoroelastomer18 to 30Any AngleNoIP65, IP670000000000000
     