    6 Products

    Insertion-Mount Flow and Temperature Transmitters

    Image of ProductInUse. Front orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Image of Product. Top orientation. Flow Transmitters. Insertion-Mount Flow and Temperature Transmitters.
    Thread mounting hardware (sold separately) into your pipe connection and insert the probe of these transmitters to measure the flow and temperature of water, oil, or air. The probe is held in place with a compression fitting on the other end of the mounting hardware. They’re often used in large-diameter pipes where it would be difficult to install a transmitter inline. To calculate the flow rate, these transmitters generate a small amount of heat, then measure the cooling effect your liquid or air has on it. They measure and output both flow and temperature, making them ideal for applications where temperature fluctuates. Also known as transducers, they convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. They’ll measure flow correctly in any mounting orientation. These transmitters are calibrated with air, glycol solutions, oil, and water but can be recalibrated in the field for other liquids.
    Adjust settings at the source using the digital display. These transmitters have two configurable outputs. One can be wired for flow or temperature as an analog output or a digital switch. The other one can be wired for flow as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. To change settings and receive error messages remotely from your PLC or computer, you can program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
    Flow Measurement
    Type
    Flow Range,
    gpm
    Probe
    Lg.
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole Micro M12 Connection Plug
     
    316 Stainless Steel/Polybutylene Body with 316 Stainless Steel Fitting
    Thermal0.02 to 123 15/16"7 9/16"-10% to 10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP67000000000000000
    Thermal0.02 to 127 7/8"11 1/2"-10% to 10%725 psi @ 212° F0 to 21218 to 30Any AngleYesIP65, IP6700000000000000
     

    Flow, Pressure, and Temperature Transmitters for Gases

    Image of Product. Front orientation. Flow Transmitters. Flow, Pressure, and Temperature Transmitters for Gases.
    Measure and transmit flow rate, pressure, and temperature of industrial gases, such as air, argon, CO2, and nitrogen, flowing through your system. These transmitters are ideal for applications where temperature and pressure can fluctuate. To calculate flow rate, they generate a small amount of heat, then measure the cooling effect your gas has on it. Also known as transducers, these transmitters convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow, temperature, and pressure increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure correctly no matter their mounting orientation.
    A digital display makes it easy to read measurements and adjust settings based on your gas. These transmitters have two configurable outputs, and each output can only be wired for one measurement (flow rate, pressure, or temperature). Outputs configured as digital pulse send flow data using spikes of voltage that match the input voltage of the transmitter. One of the outputs can be wired for IO-Link, so you can change settings and receive error messages remotely from your PLC or computer. You’ll need an IO Link controller (not included) to connect to your interface.
    These transmitters are calibrated with air but still measure accurately when used with other gases.
    Flow Measurement
    Type
    Pipe
    Connections
    Flow Range,
    scfm
    End-to-End
    Lg.
    Accuracy
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Seal Material
    Input Voltage
    Range, V DC
    Mounting
    Position
    Field
    Recalibratable
    Enclosure
    Rating
    Each
    One Digital Switch/Pulse Output and One 4-20 mA Analog Transmitter/Digital Switch/Pulse Output—4-Pole Micro M12 Connection Plug
     
    304 Stainless Steel Body with 304 Stainless Steel Fitting
    Thermal1/2 NPT Male0.15 to 4411 13/16"-6% to 6%230 psi @ 70° F14 to 140Fluoroelastomer18 to 30Any AngleNoIP65, IP6700000000000000
    Thermal1 NPT Male0.4 to 13218 3/4"-6% to 6%230 psi @ 70° F14 to 140Fluoroelastomer18 to 30Any AngleNoIP65, IP67000000000000000
     