About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Fixed-Setpoint Flow Switches
Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting orientation.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
Choose a fitting material that is compatible with the liquid you intend to run through your line. Polypropylene and PPS plastic fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
SPST (single pole, single throw) switches turn one device from off to on (normally open).
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Mounting Orientation | Each | ||
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
SPST | |||||||||||
B | 3/4 | NPT | Female | 0.25 | 0.05 | 100 psi @ 70 ° F | 0° to 212° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 0000000 | 0000000 |
B | 3/4 | NPT | Female | 0.5 | 0.1 | 100 psi @ 70 ° F | 0° to 212° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 0000000 | 000000 |
B | 3/4 | NPT | Female | 1 | 0.2 | 100 psi @ 70 ° F | 0° to 212° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 0000000 | 000000 |
Flow Switches with Sight
For monitoring flow at a glance, these switches have a plastic window with a rotor indicator that spins when there’s flow. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. To measure flow, they count how many times the turbine turns as liquid flows through. Use them only with clean, low-viscosity liquids to prevent clogging the turbine and other damage. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
Choose a fitting material that is compatible with the liquid you're running through your line. Brass and 316 stainless steel fittings resist impact better than polypropylene fittings.
Flow switches with any mounting orientation will measure accurately no matter how you orient them in your system.
For technical drawings and 3-D models, click on a part number.
Set Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Mounting Orientation | End-to-End Lg. | Specifications Met | Each | |
Brass Body with Brass Fittings | ||||||||
---|---|---|---|---|---|---|---|---|
3/4 NPT Female | ||||||||
5 to 30 | 200 psi @ 70° F | 33° to 212° | 95 mA @ 115 V AC | Any | 3 15/16" | UL Recognized Component, CE Marked | 0000000 | 0000000 |
316 Stainless Steel Body with 316 Stainless Steel Fittings | ||||||||
3/4 NPT Female | ||||||||
1.5 to 15 | 200 psi @ 70° F | 20° to 225° | 5 A @ 120 V AC 5 A @ 240 V AC | Horizontal | 5 1/4" | CE Marked, VDE Certified | 00000000 | 000000 |
5 to 30 | 200 psi @ 70° F | 33° to 212° | 95 mA @ 115 V AC | Any | 3 15/16" | UL Recognized Component, CE Marked | 0000000 | 000000 |
5 to 50 | 200 psi @ 70° F | 20° to 225° | 5 A @ 120 V AC 5 A @ 240 V AC | Horizontal | 5 1/4" | CE Marked, VDE Certified | 00000000 | 000000 |
Flow Switches
Activate or deactivate equipment when your flow rate reaches a set point. These switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They’re accurate in any mounting orientation.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Conduit | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Set Point Range, gpm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current | Trade Size | Thread Type | Gender | Port-to-Port Lg. | Each | |
Bronze Body | |||||||||||
3/4 NPT Female | 0.75 to 4 | 400 psi @ 70° F | -20° to 180° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 1 3/8" | 0000000 | 0000000 |
3/4 NPT Female | 2 to 8 | 400 psi @ 70° F | -20° to 180° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 1 3/8" | 0000000 | 000000 |
3/4 NPT Female | 7 to 14 | 400 psi @ 70° F | -20° to 180° | 120V AC/ 240V AC | 200 mA @ 240 V AC 400 mA @ 120 V AC | 1/2 | NPT | Male | 1 3/8" | 0000000 | 000000 |
Variable-Pressure Flow Switches
Accurate even in applications where pressure fluctuates regularly, these flow switches split flow into two paths and measure their difference in pressure drop to calculate the flow rate of liquid. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. They measure accurately no matter their mounting orientation. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Rated NEMA 4X and IP66, they seal out dust and protect against washdowns and corrosion.
These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
For technical drawings and 3-D models, click on a part number.
Set Point, gpm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current | Conduit Trade Size | End-to-End Lg. | Each | |
Bronze Body | ||||||||
---|---|---|---|---|---|---|---|---|
3/4 NPT Female | ||||||||
0.5 to 6 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 0000000 |
1.5 to 10 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 000000 |
2 to 15 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 000000 |
3 to 20 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 000000 |
Fixed-Setpoint Hazardous Location Flow Switches
Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments. Because their set point is fixed, they’re ready to go, making them easy to install. They actuate when your flowing liquid or gas pushes their paddle into a set position. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function accurately.
These switches are calibrated with water and air. They can also be used with other liquids and gases but may not measure accurately if their viscosity is significantly different.
For technical drawings and 3-D models, click on a part number.
Set Point | Conduit | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Type | Gender | For Liquids, gpm | For Gases, scfm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current | Trade Size | Thread Type | Gender | End-to-End Lg. | Each | |
Brass Body | ||||||||||||||
3/4 | NPT | Female | 2 | 10 | 250 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 3/8" | 00000000 | 0000000 |
304 Stainless Steel Body | ||||||||||||||
3/4 | NPT | Female | 2 | 10 | 2000 psi @ 70° F | -4° to 220° | 120V AC/ 240V AC | 5 A @ 120 V AC | 3/4 | NPT | Male | 2 5/8" | 00000000 | 000000 |
High-Pressure Flow Switches for Oil
Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting orientation.
These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, gpm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|
Brass Body with Brass Fittings | |||||||||
3/4 NPT Female | 1 to 11 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 0000000 |
3/4 NPT Female | 2 to 18 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
High-Pressure Flow Switches
Rated for pressures up to 3,600 psi, these switches measure the flow rate of liquids to activate or deactivate equipment when your flow rate reaches a set point. Tighten or loosen the adjustment screw on these switches to choose your flow rate anywhere within set point the range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Set Point | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Liquids, gpm | Gases, scfm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | ||||||||||
Brass Body with 304 Stainless Steel Fittings | ||||||||||
3/4 NPT Female | 8 to 34 | 1.067 to 4.534 | Adjustable | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 0000000 |
High-Pressure Flow Switches for Gases
Good for compressed-air systems and other compressed gases that reach up to 3,600 psi, these switches measure the flow rate to activate or deactivate equipment when they reach a set point. Tighten or loosen the adjustment screw to choose your flow rate anywhere within the set point range. As flowing gas pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
These switches are calibrated with and measure air accurately. They can also be used with other gases by applying your gases’ specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, scfm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|
Brass Body with 304 Stainless Steel Fittings | |||||||||
3/4 NPT Female | 10 to 90 | Adjustable | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 0000000 |
3/4 NPT Female | 30 to 130 | Adjustable | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 7/8" | IP65 | 0000000 | 000000 |
Electronic Flow Switches
When these switches reach a set flow rate, they send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms. Use the adjustment screw to select their set point. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They must be mounted horizontally to function correctly. IP rated, they withstand dust, washdowns, and temporary submersion.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point Range, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | End-to-End Lg. | Environmental Rating | Specifications Met | Each | |
Aluminum/Brass/Plastic Body with Nickel-Plated Brass Fittings | |||||||||
---|---|---|---|---|---|---|---|---|---|
One Digital PNP Signal Output | |||||||||
3/4 NPT Female | 0.26 to 6.6 | 360 psi @ 70° F | 32° to 185° | 100 mA @ 30 V DC | 3" | IP65, IP67 | C-UL Listed, UL Listed, CE Marked | 0000000 | 0000000 |
Insertion Flow Switches
Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Switches with a Noryl plastic body have a paddle that you trim to adjust the set point. The more you trim, the higher the set point.
Choose a fitting material that is compatible with the liquid you're running through your line. Noryl plastic fittings work with a wide range of chemicals.
Socket-connect flow switches bond to an unthreaded PVC pipe tee or pipe outlet with PVC cement and primer (not included).
IP65 rated switches seal out dust and can be lightly rinsed.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Size | Set Point Range, gpm | Max. Flow Rate, gpm | Set Point Adjustment Method | Paddle Material | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Body Ht. | Environmental Rating | Specifications Met | Each | |
Noryl Plastic Body with Noryl Plastic Fittings | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Socket Connection | |||||||||||||
3/4 | 1 1/2 2 3 | 7.7 to 19.3 10.3 to 21 16.5 to 52 | 110 150 390 | Trimmable Paddles | Noryl Plastic | 160 psi @ 70° F | -13° to 212° | 1 A @ 230 V AC 1 A @ 48 V DC | 2 1/2" | IP65 | UL 508 | 0000000 | 0000000 |
3/4 | 1 1/2 2 3 | 7.9 to 15 10 to 22 18 to 50 | 144 240 650 | Trimmable Paddles | 301 Stainless Steel | 160 psi @ 70° F | -13° to 212° | 1 A @ 230 V AC 1 A @ 48 V DC | 2 1/2" | IP65 | UL 508 | 00000000 | 000000 |
Fixed-Setpoint Insertion Flow Switches
Easy to install, these flow switches come already set to a specific set point and don’t require you to disassemble your pipeline. Instead of mounting them inline, insert them into an unthreaded PVC pipe tee or pipe outlet in large-diameter pipe. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). IP rated, they seal out dust and can be lightly rinsed.
They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle. Secure them with PVC cement and primer (not included).
These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
For technical drawings and 3-D models, click on a part number.
Pipe Size | For Pipe Size | Set Point, gpm | Max. Flow Rate, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Body Ht. | Environmental Rating | Specifications Met | Each | |
Noryl Plastic Body | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Socket Connection | |||||||||||
3/4 | 3/4 | 1.94 | 21 | 160 psi @ 70° F | -13° to 212° | 1 A @ 230 V AC, 1 A @ 48 V DC | 2 1/2" | IP65 | UL 508 | 00000000 | 0000000 |
3/4 | 1, 1 1/4 | 2.7, 6.8 | 31, 40 | 160 psi @ 70° F | -13° to 212° | 1 A @ 230 V AC, 1 A @ 48 V DC | 2 1/2" | IP65 | UL 508 | 00000000 | 000000 |
Electronic Insertion Flow Switches
Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting orientation.
IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
For technical drawings and 3-D models, click on a part number.
Set Point Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe Size | For Liquids, gpm | For Gases, scfm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Body Ht. | Probe Lg. | Environmental Rating | Specifications Met | Each | |
304 Stainless Steel Body | |||||||||||
One Digital NPN Signal Output | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 19 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 0000000 |
One Digital PNP Signal Output | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 18 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Two Digital NPN Signal Outputs | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 19 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Two Digital PNP Signal Outputs | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 18 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Noncontact Flow Transmitters
Using ultrasonic waves, these transmitters measure the flow rate of your liquid from outside your pipe. They're a good choice for applications where you need to retrofit your system or avoid liquid coming into contact with the transmitter. Also known as transducers, these transmitters convert measurements to an electrical pulse that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). The pulse outputs match the input voltage of the transmitter. The higher the flow, the more pulses they send. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Configure them for either a 4-20mA or digital pulse output when installing.
A digital display makes it easy to check flow rate and configure settings. Clamp these transmitters onto your pipe with the included mounting hardware and gel pads. They measure flow no matter the mounting orientation.
These transmitters are calibrated with water but can be used with other liquids and will generally measure accurately, even if they differ in viscosity and density. You can recalibrate them in the field for accurate readings on pipe and operating conditions.
For technical drawings and 3-D models, click on a part number.
Flow Range for Pipe Size, gpm | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe Size | 3/4 | 2 | 4 | End-to-End Lg. | Accuracy | Temp. Range, °F | Input Voltage | Mounting Orientation | Field Recalibratable | Each | |
One Digital Pulse Output and One 4-20mA Analog Transmitter Output—Wire Leads | |||||||||||
Polycarbonate Plastic Body | |||||||||||
3/4 to 4 | 0 to 45 | 0 to 320 | 0 to 1,285 | 9 3/4" | ±3% | 32° to 185° | 12V DC to 24V AC/DC | Any | Yes | 0000000 | 000000000 |
Flow Transmitters with Sight
Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.
These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Transmitters with an analog output increase their output signal as flow increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range.
Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Input Voltage | Pulse Frequency, Hz | Each | |
One 4-20mA Analog Transmitter Output—Wire Leads | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
316 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||
3/4 NPT Female | 1.5 to 15 | 5 1/4" | ±2% | 500 psi @ 70° F | 20° to 212° | Buna-N Rubber | Any | 12-24V DC | __ | 00000000 | 000000000 |
3/4 NPT Female | 5 to 50 | 5 1/4" | ±2% | 500 psi @ 70° F | 20° to 212° | Buna-N Rubber | Any | 12-24V DC | __ | 00000000 | 00000000 |
One 0-5V DC Analog Transmitter Output—Wire Leads | |||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||
3/4 NPT Female | 1.5 to 15 | 5 1/4" | ±2% | 500 psi @ 70° F | 20° to 212° | Buna-N Rubber | Any | 12-24V DC | __ | 00000000 | 00000000 |
3/4 NPT Female | 5 to 50 | 5 1/4" | ±2% | 500 psi @ 70° F | 20° to 212° | Buna-N Rubber | Any | 12-24V DC | __ | 00000000 | 00000000 |
One Digital Pulse Output—Wire Leads | |||||||||||
316 Stainless Steel Body with 316 Stainless Steel Fittings | |||||||||||
3/4 NPT Female | 5 to 30 | 3 15/16" | ±15% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Any | 4.5-24V DC | 15-225 | 0000000 | 000000 |
Flow Transmitters
Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Variable-area transmitters determine flow rate by tracking where the liquid pushes an internal piston.
Turbine transmitters measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. The digital output sends flow data with a pulse, which is a spike of voltage. The higher the flow, the more pulses they send. The voltage of the pulse output matches the input voltage sent to the transmitters. These transmitters meet NSF/ANSI 61 for use with drinking water.
For technical drawings and 3-D models, click on a part number.
Flow
Measurement
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Input Voltage | Mounting Orientation | Field Recalibratable | Each | |
One 4-20mA Analog Transmitter Output—4-Pole Micro M12 Plug Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
316L Stainless Steel/Aluminum/Brass/Plastic Body with 316 Stainless Steel/Brass Fittings | |||||||||||
3/4 NPT Female | 0.2 to 4 | 2 15/16" | ±5% | 580 psi @ 212 ° F | 14° to 212° | Fluoroelastomer | 18 to 32V DC | Any | No | 00000000 | 0000000 |
3/4 NPT Female | 0.2 to 6 | 2 15/16" | ±5% | 580 psi @ 212 ° F | 14° to 212° | Fluoroelastomer | 18 to 32V DC | Any | No | 00000000 | 000000 |
3/4 NPT Female | 0.2 to 10 | 2 15/16" | ±5% | 580 psi @ 212 ° F | 14° to 212° | Fluoroelastomer | 18 to 32V DC | Any | No | 00000000 | 000000 |
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Input Voltage | Mounting Orientation | Field Recalibratable | Maximum Output Current | Each | |
One 4-20mA Analog Transmitter/Digital Pulse Output—Wire Leads | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Polyamide Plastic Body with Polyamide Plastic Fittings | |||||||||||
3/4 NPT Male | 1.32 to 17.17 | 2 15/16" | ±3% | 362 psi @ 212 ° F | -4° to 212° | 5 to 24V DC | Any | No | 20mA | 00000000 | 0000000 |
Flow and Temperature Transmitters
Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device. Used to monitor status or control equipment, these transmitters, also known as transducers, convert measurements to an electrical signal that is interpreted by receiving devices. As flow or temperature increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them inline with your pipe system. They’ll measure flow correctly in any mounting orientation.
A digital display makes it easy to view readings and adjust settings at the source. To change settings and receive error messages remotely from your PLC or computer, program one of the outputs to use IO Link. You’ll need an IO Link controller (not included) to connect to your interface.
Variable-area transmitters determine the flow rate by tracking where the liquid pushes the piston. They have two configurable outputs. One can be wired as an analog output or a digital switch. The other one can be wired as a digital switch, digital pulse output, or IO Link. Pulse outputs send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send. These transmitters are calibrated with water, glycol solutions, and coolants but can be recalibrated in the field for other liquids.
Vortex transmitters determine the flow rate by measuring the size of the vortex created as liquid flows through them. They don’t have any moving parts that can break or get stuck. Use them only with liquids that are at least 95% water. They have one analog output for flow and another for temperature. The output for temperature can also be wired for IO Link.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Flow Range, gph | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Input Voltage | Plug Type | Mounting Orientation | Field Recalibratable | Each | |
One Digital Switch/Pulse Output and One 4-20mA Analog Transmitter/Digital Switch Output | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
316 Stainless Steel Body with 316 Stainless Steel Fittings | ||||||||||||
3/4 NPT Female | 5 to 240 | 5 9/16" | ±5% | 580 psi @ 70° F | 14° to 212° | Fluoroelastomer Rubber | 18 to 30V DC | 4-Pole Micro M12 | Any | Yes | 0000000 | 0000000 |
3/4 NPT Female | 7 to 360 | 5 9/16" | ±5% | 580 psi @ 70° F | 14° to 212° | Fluoroelastomer Rubber | 18 to 30V DC | 4-Pole Micro M12 | Any | Yes | 0000000 | 000000 |
3/4 NPT Female | 10 to 600 | 5 9/16" | ±5% | 580 psi @ 70° F | 14° to 212° | Fluoroelastomer Rubber | 18 to 30V DC | 4-Pole Micro M12 | Any | Yes | 0000000 | 000000 |
Pipe Connections | Flow Range, gph | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Input Voltage | Plug Type | Mounting Orientation | Field Recalibratable | Each | |
Two 4-20mA Analog Outputs | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
316 Stainless Steel Body with 316 Stainless Steel Fittings | ||||||||||||
3/4 NPT Female | 80 to 1,585 | 5 15/32" | ±2% | 172 psi @ 70° F | 14° to 190° | Fluoroelastomer Rubber | 18 to 30V DC | 4-Pole Micro M12 | Any | No | 0000000 | 0000000 |
High-Accuracy Flow and Temperature Transmitters
Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy. Because they use a magnetic field, they only work with conductive liquids, such as water. These transmitters, also known as transducers, convert measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs) to monitor flow or control equipment. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. As flow or temperature increases, the output signal increases. These transmitters have one analog output for flow and another for temperature. They only give accurate readings within the rated measurement range. A digital display makes it easy to view readings and adjust settings at the source. Mount these transmitters inline with your pipe system. They measure flow correctly in any mounting orientation.
These transmitters are calibrated with water. They can only be used with liquids with a conductivity of at least 20 µS/cm.
For technical drawings and 3-D models, click on a part number.
Flow Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connection | Gallons per Minute | Liters per Minute | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Mounting Orientation | Input Voltage Range | Environmental Rating | Each | |
Two 4-20mA Analog Outputs—4-Pole Micro M12 Plug Connection | |||||||||||
316 Stainless Steel/Polybutylene Plastic/Thermoplastic Body with 316 Stainless Steel Fittings | |||||||||||
3/4 NPT Female | 0.02 to 13.22 gpm | 0.2 to 50 lpm | 2 1/8" | ±2% | 225 psi @ 70° F | 0° to 175° | Any | 20-30V DC | IP67 | 00000000 | 0000000 |