About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
Fixed-Setpoint Flow Switches
Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They’re accurate in any mounting orientation.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
Choose a fitting material that is compatible with the liquid you intend to run through your line. Polypropylene and PPS plastic fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened.
SPST (single pole, single throw) switches turn one device from off to on (normally open).
SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or from on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | End-to-End Lg. | Mounting Orientation | Each | |
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
SPST | |||||||||||
1/4 | NPT | Female | 0.1 | 0.1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 000000 |
1/4 | NPT | Female | 0.25 | 0.25 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
1/4 | NPT | Female | 0.5 | 0.5 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
1/4 | NPT | Female | 0.75 | 0.75 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
1/4 | NPT | Female | 1 | 1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | 4 7/8" | Any | 0000000 | 00000 |
Pipe Size | Thread Type | Gender | Set Point, gpm | Approx. Difference Between Setpoint and Reset Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Mounting Orientation | Each | ||
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
SPST | |||||||||||
A | 1/4 | NPT | Female | 0.042 | 0.006 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 000000 |
A | 1/4 | NPT | Female | 0.1 | 0.1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 0.25 | 0.25 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 0.5 | 0.5 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 0.75 | 0.75 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
A | 1/4 | NPT | Female | 1 | 1 | 200 psi @ 70 ° F | 33° to 194° | 500 mA @ 300 V AC 700 mA @ 350 V DC | Any | 0000000 | 00000 |
PPS Plastic Body with PPS Plastic Fittings | |||||||||||
SPDT | |||||||||||
A | 1/4 | NPT | Female | 0.1 | 0.02 | 250 psi @ 70 ° F | 0° to 225° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 00000000 | 000000 |
A | 1/4 | NPT | Female | 0.25 | 0.05 | 250 psi @ 70 ° F | 0° to 225° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 00000000 | 000000 |
A | 1/4 | NPT | Female | 1 | 0.2 | 250 psi @ 70 ° F | 0° to 225° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 00000000 | 000000 |
A | 1/4 | NPT | Female | 1.5 | 0.3 | 250 psi @ 70 ° F | 0° to 225° | 400 mA @ 30 V AC 170 mA @ 120 V AC 80 mA @ 240 V AC 300 mA @ 30 V DC 130 mA @ 120 V DC 60 mA @ 240 V DC | Any | 00000000 | 000000 |
Flow Switches with Sight
For monitoring flow at a glance, these switches have a plastic window with a rotor indicator that spins when there’s flow. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. To measure flow, they count how many times the turbine turns as liquid flows through. Use them only with clean, low-viscosity liquids to prevent clogging the turbine and other damage. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
Choose a fitting material that is compatible with the liquid you're running through your line. Polypropylene fittings work with a wide range of chemicals. However, they can crack from impact or when overtightened. Brass and 316 stainless steel fittings resist impact better than polypropylene fittings.
Flow switches with any mounting orientation will measure accurately no matter how you orient them in your system.
For technical drawings and 3-D models, click on a part number.
Set Point, gpm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Mounting Orientation | End-to-End Lg. | Specifications Met | Each | |
Polypropylene Plastic Body with Polypropylene Plastic Fittings | ||||||||
---|---|---|---|---|---|---|---|---|
1/4 NPT Female | ||||||||
0.1 to 5 | 100 psi @ 70° F | 33° to 180° | 95 mA @ 115 V AC | Any | 3 1/16" | UL Recognized Component, CE Marked | 0000000 | 0000000 |
Brass Body with Brass Fittings | ||||||||
1/4 NPT Female | ||||||||
0.1 to 5 | 200 psi @ 70° F | 33° to 212° | 95 mA @ 115 V AC | Any | 3" | UL Recognized Component, CE Marked | 0000000 | 000000 |
Variable-Pressure Flow Switches
Accurate even in applications where pressure fluctuates regularly, these flow switches split flow into two paths and measure their difference in pressure drop to calculate the flow rate of liquid. They activate or deactivate equipment when the flow rate reaches your set point. Tighten or loosen the adjustment screw to choose your set point anywhere within the range. They measure accurately no matter their mounting orientation. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). Rated NEMA 4X and IP66, they seal out dust and protect against washdowns and corrosion.
These switches are calibrated with water. They can also be used with other liquids but may not measure accurately if their viscosity is significantly different.
For technical drawings and 3-D models, click on a part number.
Set Point, gpm | Max. Pressure | Temp. Range, °F | Voltage | Max. Switching Current | Conduit Trade Size | End-to-End Lg. | Each | |
Bronze Body | ||||||||
---|---|---|---|---|---|---|---|---|
1/4 NPT Female | ||||||||
0.3 to 2 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 0000000 |
0.4 to 3 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 000000 |
0.5 to 4 | 400 psi @ 70° F | -30° to 212° | 120V AC/ 175V DC | 180 mA @ 120 V AC 250 mA @ 175 V DC | 1/2 | 3 1/16" | 00000000 | 000000 |
Fixed-Setpoint High-Pressure Flow Switches
Quicker to install than adjustable flow switches in high-pressure lines, these switches come factory-set to activate or deactivate equipment at a specific level. They compensate for the viscosity and density changes of liquid. As flowing liquid pushes an internal piston, the switch reads the piston's position to measure the flow. When the piston passes the set point, the switch actuates. All measure flow correctly no matter their mounting orientation.
These switches are calibrated with water. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new setpoint.
SPDT (single pole, double throw) switches can either turn one device from off to on (normally open) or on to off (normally closed).
For technical drawings and 3-D models, click on a part number.
Approximate Difference Between Setpoint and Reset Point | Conduit | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Set Point, gpm | Liquids, gpm | Gases, scfm | Max. Pressure | Temp. Range, °F | Max. Switching Current | Trade Size | Thread Type | Gender | Port-to-Port Lg. | Each | |
SPDT | ||||||||||||
Brass Body with Brass Fittings | ||||||||||||
1/4 NPT Female | 0.013 | 0.0195 | 0.03 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 0000000 |
1/4 NPT Female | 0.1 | 0.015 | 0.01 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 000000 |
1/4 NPT Female | 0.25 | 0.0375 | 0.01 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 000000 |
1/4 NPT Female | 0.5 | 0.075 | 0.01 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 000000 |
1/4 NPT Female | 0.75 | 0.1125 | 0.02 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 000000 |
1/4 NPT Female | 1 | 0.15 | 0.02 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 000000 |
1/4 NPT Female | 1.5 | 0.225 | 0.03 | 1000 psi @ 70° F | -20° to 225° | 0.4 A @ 30 V AC 0.17 A @ 120 V AC 0.08 A @ 240 V AC 0.3 A @ 30 V DC 0.13 A @ 120 V DC 0.06 A @ 240 V DC | 1/2 | NPT | Female | 2 1/16" | 0000000 | 000000 |
High-Pressure Flow Switches for Oil
Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting orientation.
These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, gpm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|
Brass Body with Brass Fittings | |||||||||
1/4 NPT Female | 0.03 to 0.12 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 0000000 |
1/4 NPT Female | 0.05 to 0.3 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 0.2 to 0.9 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 0.5 to 2.5 | Adjustable | 3600 psi @ 70° F | 212° | 1 A @ 100 V AC 0.42 A @ 240 V AC 1 A @ 60 V DC 0.26 A @ 230 V DC | 6 3/8" | IP65 | 0000000 | 000000 |
High-Pressure Flow Switches
Rated for pressures up to 3,600 psi, these switches measure the flow rate of liquids to activate or deactivate equipment when your flow rate reaches a set point. Tighten or loosen the adjustment screw on these switches to choose your flow rate anywhere within set point the range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Set Point | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Liquids, gpm | Gases, scfm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | ||||||||||
Brass Body with 304 Stainless Steel Fittings | ||||||||||
1/4 NPT Female | 0.06 to 0.08 | 0.008 to 0.107 | Adjustable | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 0000000 |
1/4 NPT Female | 0.25 to 2.6 | 0.033 to 0.347 | Adjustable | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 0.3 to 6 | 0.04 to 0.8 | Adjustable | 3600 psi @ 70° F | 212° | 1.5 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
High-Pressure Flow Switches for Gases
Good for compressed-air systems and other compressed gases that reach up to 3,600 psi, these switches measure the flow rate to activate or deactivate equipment when they reach a set point. Tighten or loosen the adjustment screw to choose your flow rate anywhere within the set point range. As flowing gas pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). They must be mounted horizontally to function correctly. IP rated, they seal out dust and can be lightly rinsed.
These switches are calibrated with and measure air accurately. They can also be used with other gases by applying your gases’ specific-gravity conversion factor to calculate the new set point.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Set Point, scfm | Approximate Difference Between Setpoint and Reset Point | Max. Pressure | Max. Temp., °F | Max. Switching Current | Port-to-Port Lg. | Environmental Rating | Each | |
SPDT | |||||||||
---|---|---|---|---|---|---|---|---|---|
Brass Body with 304 Stainless Steel Fittings | |||||||||
1/4 NPT Female | 0.4 to 4 | Adjustable | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 0000000 |
1/4 NPT Female | 2 to 10 | Adjustable | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
1/4 NPT Female | 3 to 24 | Adjustable | 3600 psi @ 70° F | 212° | 0.8 A @ 240 V AC | 5 3/16" | IP65 | 0000000 | 000000 |
Electronic Insertion Flow Switches
Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting orientation.
IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
For technical drawings and 3-D models, click on a part number.
Set Point Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Pipe Size | For Liquids, gpm | For Gases, scfm | Max. Pressure | Temp. Range, °F | Max. Switching Current @ Voltage | Body Ht. | Probe Lg. | Environmental Rating | Specifications Met | Each | |
304 Stainless Steel Body | |||||||||||
One Digital NPN Signal Output | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 19 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 0000000 |
One Digital PNP Signal Output | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 18 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Two Digital NPN Signal Outputs | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 19 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Two Digital PNP Signal Outputs | |||||||||||
1/4 1/2 3/4 1 | 0.02 to 1.5 0.05 to 4.9 0.13 to 12.7 0.23 to 23 | 0.14 to 2 0.54 to 8.05 1.21 to 18.11 2.15 to 32.21 | 4300 psi @ 70° F | -10° to 175° | 250 mA @ 18 V DC 250 mA @ 36 V DC | 2 11/16" | 1 13/16" | IP65, IP67 | C-UL Listed, CE Marked, UL Listed | 0000000 | 000000 |
Flow Transmitters with Sight
Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing. They measure flow by counting how many times the turbine turns as the liquid moves through it. To prevent clogging the turbine and other damage, use them only with clean, low-viscosity liquids. These transmitters, also known as transducers, convert the flow measurement to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs), to monitor flow or control equipment. Mount them directly inline with your system. They measure accurately in any mounting orientation.
These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Transmitters with a digital pulse output send flow data using spikes of voltage that match the input voltage of the transmitter. The higher the flow, the more pulses they send.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Input Voltage | Pulse Frequency, Hz | Each | |
One Digital Pulse Output—Wire Leads | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||
1/4 NPT Female | 0.1 to 5 | 3 1/16" | ±7% | 100 psi @ 70° F | 33° to 180° | Fluoroelastomer Rubber | Any | 4.25-24V DC | 15-225 | 0000000 | 0000000 |
Brass Body with Brass Fittings | |||||||||||
1/4 NPT Female | 0.1 to 5 | 3" | ±7% | 200 psi @ 70° F | 33° to 212° | Fluoroelastomer Rubber | Any | 4.5-24V DC | 15-225 | 0000000 | 000000 |
Flow Transmitters
Send flow rate measurements to monitor and control equipment. Also known as transducers, these transmitters convert flow rate measurements to an electrical signal that can be interpreted by receiving devices, such as remote displays and programmable logic controllers (PLCs). As flow increases, the output signal increases. For your receiving device to interpret the signal, you will need to calibrate it for the measurement range and output signal of the transmitter. They only give accurate readings within the rated measurement range. Mount them directly inline with your system. They measure flow correctly no matter their mounting orientation.
These transmitters are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Turbine transmitters measure flow by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage, use them only with clean, low-viscosity liquids. The digital output sends flow data with a pulse, which is a spike of voltage. The higher the flow, the more pulses they send. The voltage of the pulse output matches the input voltage sent to the transmitters. These transmitters meet NSF/ANSI 61 for use with drinking water.
For technical drawings and 3-D models, click on a part number.
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Max. Pressure | Temp. Range, °F | Input Voltage | Mounting Orientation | Field Recalibratable | Maximum Output Current | Each | |
One 4-20mA Analog Transmitter/Digital Pulse Output—Wire Leads | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Polyamide Plastic Body with Polyamide Plastic Fittings | |||||||||||
1/4 NPT Male | 0.026 to 0.65 | 1 3/4" | ±3% | 362 psi @ 212 ° F | -4° to 212° | 5 to 24V DC | Any | No | 20mA | 00000000 | 0000000 |