We will reply to your message within an hour.
More
Quickly vent exhaust air to the atmosphere or divert it to another place in your system to speed up the movement of equipment. The 90° elbow shape allows you to install them in tight spaces. Also known as quick exhaust valves.
Control the flow of exhaust air while also regulating the exhaust air speed. These valves dump exhaust air to the atmosphere without routing it back through a directional control valve. The 90° elbow shape allows you to install them in tight spaces. Also known as quick exhaust valves.
Quickly dump exhaust air to the atmosphere without routing it back through a directional control valve to speed up the movement of equipment. Also known as quick exhaust valves.
A muffler reduces exhaust noise. Valves allow airflow into your equipment and then quickly dump exhaust air to the atmosphere without routing it back through a directional control valve to speed up the movement of equipment. Also known as quick exhaust valves.
Install these valves in the exhaust ports of air directional control valves to control exhaust air speed without needing access to your cylinder.
Choose the pressure range you need. When these valves receive an air signal, they quickly dump exhaust air to the atmosphere without routing it back through a directional control valve to speed up the movement of equipment. They're often used with air compressors that require continuous operation. Also known as quick exhaust valves.
Prevent accidental start-up when servicing equipment.
Also known as Monday-morning valves, these valves slowly introduce pressure to reduce surge damage during start-up.
Change set pressure to suit your application—this valve includes four interchangeable color-coded springs with different set pressure ranges.
Body is brass or nickel-plated brass. All meet ASME Code Section VIII for use with air and inert gas pressure vessels.
For corrosion resistance in wet conditions and harsh environments, these valves have a 303 stainless steel body. All meet ASME Code Section VIII for use with air and inert gas pressure vessels.
The most basic option for air and inert gas applications.
These valves have a bronze body for durability and a long service life. All meet ASME Code Section VIII for use with air and inert gas pressure vessels.
Commonly used with high-volume blowers, compressors, and air-powered conveyors, these valves quickly relieve a large amount of air in systems with a pipe size of 2 or greater. All meet ASME Code Section VIII for use with air and inert gas pressure vessels.
Commonly used with high-volume blowers, compressors, and air-powered conveyors, these valves quickly relieve a large amount of air in systems with a pipe size of 2 or greater.
With a 316 stainless steel body for exceptional corrosion resistance, these valves are often used in wet conditions and harsh environments. All meet ASME Code Section VIII for use with air and inert gas pressure vessels.
Use these valves with liquid argon, liquid nitrogen, and liquid oxygen.
Our only valves that meet ASME Code Section VIII for use with cryogenic pressure vessels. They are for use with argon, carbon dioxide, helium, hydrogen, methane, nitrogen, and oxygen.
Choose these valves for small steam-heating boilers requiring pressure relief between 5 psi and 12 psi.
Also known as T & P valves, these open when water temperature reaches 210° F or at the set pressure.
Protect your water-heating system with these valves that meet ASME Code Section IV for hot water heaters and boilers.
For use with low-pressure steam-heating boilers requiring pressure relief at 15 psi, these valves meet ASME Code Section IV.
These valves meet ASME Code Section VIII for use with water pressure vessels.
These valves meet ASME Code Section I for use with steam power boilers requiring pressure relief above 15 psi.
Less than a quarter of the height of standard pressure-relief valves, these are often installed on tanks in low-clearance areas.
For a low-pressure seal around plastic and soft metal tubing, these valves have push-to-connect fittings.
A finely threaded adjustment screw lets you make precise set pressure adjustments.
These valves are often used with catalysts, pH buffers, and electroplating solutions.
With a three-port design, these valves allow inline flow from the inlet to the outlet during normal conditions and divert flow through the relief port in overpressure conditions. They are often used with feed pumps for fertilizers and bleach.
To gradually relieve pressure in lines for diesel fuel, fuel oil, gasoline, and kerosene, these valves begin opening at the set pressure and fully open at about 10% over the set pressure.
Change set pressure without guesswork—the adjustment screw is marked in 25 psi increments for making pressure adjustments without a gauge.
These valves are commonly used with pumps in low-pressure water systems.
Alter the set pressure to suit your application.
These valves are often used in hydraulic and lubrication systems.
Design a valve specifically for your process media and set pressure. Choose from a valve for air, inert gas, water, hydraulic oil, fuel oil, gasoline, or diesel fuel and a set pressure.
Cleaned and bagged for oxygen service and other high-purity applications, these valves are built to withstand the extreme cold of liquid carbon dioxide, liquid nitrogen, and liquid oxygen.
Threads below the adjustment knob and an included panel-mount nut allow you to add these valves to your instrument panel.
Use these valves in pipelines.
These valves have a cast iron body.
For a longer service than cast iron valves, these have a durable bronze body and a 303 stainless steel seal.
Designed to meet 3-A sanitary standards, these valves regulate liquid, gas, and air pressure in hygienic zones of food and beverage plants.
Maintain contaminant-free standards in clean room environments. These valves come cleaned and bagged to Fed. Spec. Class 100 and ISO Class 5 clean room standards and have a 316 stainless steel body with a smooth finish to resist dust collection.
Designed to reduce contaminants in high-purity applications using hydrogen and methane gas, these valves have a stainless steel and brass body with a smooth finish to reduce dust collection and internal components designed to protect the seal and diaphragm from contamination.
For excellent corrosion resistance in wet conditions and harsh environments, these valves have no metal parts.
Body is brass.
These valves are made of corrosion-resistant materials for use in wet conditions and harsh environments.
Turn the key to manually vent radiators and heaters.
An internal wire brush traps air bubbles and discharges them through the top relief port while allowing inline flow from the inlet to the outlet.
Use this valve with oil, diesel fuel, gasoline, and kerosene.
Our only air-release valves for steam, these seal shut when steam enters the valve to prevent system contents from escaping through the relief port.
Eliminate air pockets in your drinking water system with these valves. They meet NSF/ANSI 61, which designates them as safe to use with drinking water.
Start or stop flow with the flip of a toggle switch or the push of a button. They fit through a cutout, so the body of the valve stays safe inside your instrumentation panel.
Push a button or flip a toggle switch to start or stop flow.
For applications that require intermittent operation, such as spraying and washing, push or pull the lever on these valves to start flow. They spring closed when the lever is released.
Flip the toggle to quickly turn these valves on and off. All have threads and a hex nut below the handle for installation in instrument panels. For extra gripping power and a strong seal, they have Yor-Lok fittings with two sleeves that bite into tubing as you tighten the nut. All are compatible with Swagelok®, Let-Lok, and Parker A-Lok fittings. These valves are for use with water, oil, air, and inert gas.
Repair actuated on/off valves from Asco, Burkert, Granzow, and Parker with these kits that include replacement seals, plunger assemblies, and springs.
The pressure setting on these valves cannot be adjusted while they are installed.
An external nut lets you adjust the pressure without disassembling the valve.
To set the pressure, unscrew the cap and turn the adjusting screw.
Set a specific pressure and these valves will maintain it.
Set a specific pressure and these valves will maintain it by diverting excess fluid to a tank.