About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans
Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 8" | 520 | Not Rated | 3,125 | 1 | 1/10 | 12 1/4" | 12 1/4" | 3 1/8" | 8 | 149° F | Steel | Steel | UL Recognized Component | 000000 | 0000000 |
3 | 8" | 400 | 34 dBA @ 15 ft. | 1,550 | 1 | 1/30 | 13" | 13" | 6 5/8" | 15 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 |
Direct-Drive Wall-Mount Exhaust Fans
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations. Use a collar (sold separately) to connect these fans to a louver.
For technical drawings and 3-D models, click on a part number.