About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Direct-Drive Wall-Mount Exhaust Fans with Louvers
These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
Fans that cannot be sold to California are restricted by local energy efficiency requirements.

For Opening | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Housing Material | Frame Material | Blade Material | Specifications Met | Cannot Be Sold To | Each | |
230/460V AC, Three Phase—Hardwire | |||||||||||||||||
36" | 12,300 | 74 dBA @ 5 ft. | 850 | 1 | 1 1/2 | 43 1/4" | 43 1/4" | 45 1/2" | 45 1/2" | 31 1/2" | Steel | Galvanized Steel | Aluminum | C-UL Listed, UL Listed | CA | 00000000 | 000000000 |
Belt-Drive Wall-Mount Exhaust Fans with Louvers
These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations. Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.

For Opening | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Housing Material | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Each | |
Open Dripproof Motor Enclosure | |||||||||||||||||||
120V AC, Single Phase—Hardwire | |||||||||||||||||||
36" | 8,100 | 53 dB @ 5 ft. | 400 | 1 | 1/2 | 43" | 43" | 42 1/2" | 42 1/2" | 19" | 121 | 104° F | Steel | Steel | Steel | No | 3/16" | 0000000 | 000000000 |
Totally Enclosed Motor Enclosure | |||||||||||||||||||
230/460V AC, Three Phase—Hardwire | |||||||||||||||||||
36" | 8,100 | 53 dB @ 5 ft. | 400 | 1 | 1/2 | 43" | 43" | 42 1/2" | 42 1/2" | 25" | 225 | 104° F | Steel | Steel | Steel | No | 3/16" | 0000000 | 00000000 |
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans


Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | ||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Each | Each | |||
120V AC, Single Phase—Hardwire | |||||||||||||||||
4 | 36" | 8,600 | 65 dB @ 5 ft. | 825 | 1 | 1/2 | 42" | 42" | 12 1/4" | 95 | 104° F | Steel | Steel | 0000000 | 000000000 | 0000000 | 0000000 |
208-230/460V AC, Three Phase—Hardwire | |||||||||||||||||
4 | 36" | 8,600 | 64 dB @ 5 ft. | 1,140 | 1 | 3/4 | 42" | 42" | 12 1/4" | 95 | 104° F | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||||||
5 | 36" | 20,300 | 83 dB @ 5 ft. | 1,750 | 1 | 5 | 42" | 42" | 15 3/4" | 225 | 104° F | Steel | Steel | 0000000 | 00000000 | 0000000 | 000000 |
Belt-Drive Wall-Mount Exhaust Fans
Use these fans to draw stagnant and humid air out of a room or area. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.


Fans | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Frame Material | Blade Material | Each | Each | ||
120V AC, Single Phase—Hardwire | ||||||||||||||
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 000000000 | 0000000 | 0000000 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||
36" | 10,600 | 56 dB @ 5 ft. | 425 | 1 | 1/2 | 42" | 42" | 18 5/8" | Steel | Steel | 0000000 | 000000 | 0000000 | 000000 |

For Blade Dia. | Each | |
36" | 00000000 | 000000 |

Blade | ||||
---|---|---|---|---|
Dia. | Material | No. of | Each | |
36" | Galvanized Steel | 4 | 00000000 | 0000000 |
Dust-Resistant Belt-Drive Wall-Mount Exhaust Fans


Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Belt-drive fans are quieter and have a longer life span than direct-drive fans because components can be replaced if worn or damaged. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Exterior-Wall-Mount Exhaust Fans

Good when you don't have room to mount an exhaust fan inside your facility, these fans attach to openings in outside walls. Use them to draw stagnant and humid air out of a room or area.
Direct-drive fans have fewer moving parts than belt-drive fans, so they’re easier to maintain. Fans with a totally enclosed motor enclosure can be used in dirty, dusty, and damp environments. They mount through the wall, so you'll need to cut a hole on the inside of the wall as well.
Note: Airflow depends on the resistance created by louvers, filters, and ductwork in your system. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow @ Static Pressure | Drive Type | Motor Speed, rpm | Power, hp | Dia. | Ht. | Wd. | Dia. | Dp. | Motor Enclosure Type | Includes | Each | |
120/230V AC, Single Phase—Hardwire | |||||||||||||
36" | 5,800 cfm @ 0.2 in. of H₂O 10,500 cfm @ 0 in. of H₂O | Direct | 825 | 1/2 | 36" | 44" | 44" | 53" | 57" | Totally Enclosed | Louvers | 0000000 | 000000000 |
230/460V AC, Three Phase—Hardwire | |||||||||||||
36" | 6,700 cfm @ 0.2 in. of H₂O 11,200 cfm @ 0 in. of H₂O | Direct | 825 | 1/2 | 36" | 44" | 44" | 53" | 57" | Totally Enclosed | Louvers | 0000000 | 00000000 |
Direct-Drive Upblast Roof-Mount Exhaust Fans

Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Fans | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | ||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Each | Each | |||
Totally Enclosed Motor Enclosure | |||||||||||||||
460V AC, Three Phase—Hardwire | |||||||||||||||
2 | 36" | 14,800 cfm @ 0 in. of H₂O | 68 dBA @ 5 ft. | 1,150 | 1 | 44" | 26 3/4" | 48" | 370 | 120° | Steel | 0000000 | 000000000 | 0000000 | 0000000 |
Direct-Drive Downdraft Roof-Mount Exhaust Fans

Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | |||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Specifications Met | Each | Each | |||
Open Dripproof Motor Enclosure | ||||||||||||||||
208/230V AC, Three Phase—Hardwire | ||||||||||||||||
3 | 36" | 11,000 cfm @ 1/2 in. of H₂O 13,500 cfm @ 0 in. of H₂O | 64 dBA @ 5 ft. | 450 | 5 | 63 5/16" | 49 1/2" | 44" | 532 | 120° | Aluminum | AMCA Certified, ETL Listed | 0000000 | 000000000 | 0000000 | 0000000 |
Hazardous Location Upblast Roof-Mount Exhaust Fans

With a UL-listed motor, these fans can be used in hazardous environments with combustible gases and dust to draw stagnant and humid air out through your roof, forcing it up and away from its surface.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance.
Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged.
For technical drawings and 3-D models, click on a part number.
Fans | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | ||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Environmental Rating | Each | Each | ||
Totally Enclosed Motor Enclosure | |||||||||||||||
240/460V AC, Three Phase—Hardwire | |||||||||||||||
36" | 15,700 cfm @ 1/2 in. of H₂O 21,000 cfm @ 0 in. of H₂O | 79 dBA @ 5 ft. | 1,150 | 3 | 45" | 31" | 48" | 480 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 000000000 | 0000000 | 0000000 |
Fans | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | ||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Environmental Rating | Each | Each | ||
Totally Enclosed Motor Enclosure | |||||||||||||||
240/460V AC, Three Phase—Hardwire | |||||||||||||||
36" | 20,200 cfm @ 1/2 in. of H₂O 24,100 cfm @ 0 in. of H₂O | 82 dBA @ 5 ft. | 1,750 | 5 | 45" | 31" | 48" | 590 | 100° | Steel | NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G | 0000000 | 000000000 | 0000000 | 0000000 |
Hazardous Location Exhaust Fans

These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
Belt-drive fans are quieter and last longer than direct-drive fans because their components can be replaced if they’re worn or damaged. They come with collars, so you can connect these fans to a louver.
Fans that cannot be sold to California do not meet energy efficiency requirements.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Drive Type | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Housing Material | Blade Material | Environmental Rating | Includes | Cannot Be Sold To | Each | Each | ||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||||
36" | 11,000 | 72 dBA @ 10 ft. | Belt | 1,725 | 1 | 3/4 | 40 3/4" | 40 3/4" | 30" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | Collar | __ | 0000000 | 000000000 | 000000 | 00 |
230/460V AC, Three Phase—Hardwire | ||||||||||||||||||
36" | 15,500 | 80 dBA @ 5 ft. | Direct | 1,125 | 1 | 2 | 42 1/8" | 42 1/8" | 29 3/4" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | __ | CA | 0000000 | 00000000 | 0000000 | 0000000 |