About Exhaust Fans
More
About Sound Levels
Measured in decibels (dB), volume ratings indicate how much noise equipment makes. Some common volume levels include a whisper @ 20 dB, a refrigerator @ 40 dB, a conversation @ 60 dB, and a light machine shop @ 90 dB. OSHA recommends hearing protection for exposure to 80 dB and greater.
Light Duty Direct-Drive Wall-Mount Exhaust Fans with Louvers
These light duty fans are designed for use without duct. They come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Ambient Temperature | Control Type | Frame Material | Blade Material | Mount. Fasteners Included | Mount. Hole Dia. | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||||
12" | 825 | 1,560 | 3 | 1/12 | 12 1/2" | 12 1/2" | 15" | 15" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 5/16" | UL Recognized Component | 00000000 | 0000000 |
120V AC, Single Phase—Three-Prong Plug | ||||||||||||||||||
12" | 825 | 1,560 | 3 | 1/12 | 12 1/2" | 12 1/2" | 15" | 15" | 9 1/2" | 100° F | Pull Switch | Steel | Aluminum | No | 5/16" | UL Recognized Component | 00000000 | 000000 |
Direct-Drive Wall-Mount Exhaust Fans with Louvers
These fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have an open dripproof motor enclosure for relatively clean, dry, indoor locations. They also have a wire mesh inlet guard to protect the fan from debris.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Housing Material | Frame Material | Blade Material | Specifications Met | Each | |
120V AC, Single Phase—Hardwire | ||||||||||||||||
12" | 1,500 | 60 dBA @ 5 ft. | 1,550 | 1 | 1/8 | 17 1/4" | 17 1/4" | 19 1/2" | 19 1/2" | 20 3/4" | Steel | Galvanized Steel | Aluminum | C-UL Listed, UL Listed | 00000000 | 000000000 |
For Airflow, cfm | Motor Speed, rpm | Power, hp | Each | |
120V AC, Single Phase | ||||
---|---|---|---|---|
1,500 | 1,550 | 1/8 | 00000000 | 0000000 |
Corrosion-Resistant Direct-Drive Wall-Mount Exhaust Fans with Louvers
Rust won't be a problem with the durable plastic housing and louvers on these fans. The fans come complete with a movable-blade louver. The louvers are gravity operated so they open only when air flows through them, which prevents backdrafts. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area. All have a totally enclosed motor enclosure, which can be used in dirty, dusty, and damp environments.
For technical drawings and 3-D models, click on a part number.
For Opening | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Max. Ambient Temperature | Housing Material | Blade Material | Each | |
120/230V AC, Single Phase—Hardwire | ||||||||||||||
12" | 1,300 | 1,700 | 1 | 1/3 | 17 1/2" | 18 1/2" | 21 1/4" | 20 3/4" | 20 5/8" | 104° F | Fiberglass | Polypropylene Plastic | 0000000 | 0000000 |
Dust-Resistant Direct-Drive Wall-Mount Exhaust Fans
Better suited for dirty, dusty, and damp environments than standard direct-drive fans, these have a totally enclosed motor enclosure. Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Collars and louvers are sold separately. Use a collar to connect a wall-mount exhaust fan to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Wt., lbs. | Max. Ambient Temperature | Frame Material | Blade Material | Specifications Met | Each | Each | |||
120V AC, Single Phase—Hardwire | ||||||||||||||||||
1 | 12" | 1,500 | Not Rated | 2,850 | 1 | 1/4 | 17" | 17" | 3 3/4" | 14 | Not Rated | Steel | Steel | UL Recognized Component | 000000 | 0000000 | 000000 | 00 |
3 | 12" | 825 | Not Rated | 1,560 | 3 | 1/12 | 14 1/2" | 14 1/2" | 11" | 14 | 100° F | Steel | Aluminum | UL Recognized Component | 0000000 | 000000 | 000000 | 00 |
3 | 12" | 1,300 | 40 dBA @ 15 ft. | 1,725 | 1 | 1/4 | 20" | 20" | 8 7/8" | 21 | 104° F | Steel | Aluminum | __ | 0000000 | 000000 | 0000000 | 0000000 |
Direct-Drive Wall-Mount Exhaust Fans
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Use these fans to draw stagnant and humid air out of a room or area.
Fans with an open dripproof motor enclosure are for relatively clean, dry, indoor locations. Use a collar (sold separately) to connect these fans to a louver.
Fans with louvers create a weather-tight seal when they're turned off. The louvers open automatically on startup and spring closed when not in use.
Weather hoods (sold separately) help extend the life of your exhaust fan by protecting it from harsh weather, such as severe wind, and debris.
For technical drawings and 3-D models, click on a part number.
Overall | Mounting Hole | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Blade Material | Guard Material | Dia. | Location | No. of | Each | |
12" | 800 | 55 dBA @ 5 ft. | 1,550 | 3 | 1/12 | 16 9/16" | 16 9/16" | 7 3/4" | Aluminum | Steel | 1/4" | Guard | 4 | 0000000 | 0000000 |
Fans (Includes Louvers) | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Opening | Overall | Mounting Hole | Weather Hoods | ||||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Ht. | Wd. | Dp. | Frame Material | Blade Material | Dia. | Location | No. of | Each | Each | ||
12" | 900 | Not Rated | 1,725 | 1 | 1/10 | 13 3/4" | 13 3/4" | 16 1/8" | 16 1/8" | 15 3/16" | Galvanized Steel | Aluminum | 3/16" | Frame | 4 | 0000000 | 0000000 | 00000000 | 000000 |
Direct-Drive Upblast Roof-Mount Exhaust Fans
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. These exhaust fans draw stagnant and humid air out through your roof and then expel it up and away from the roof surface. All fans have a disconnect switch to turn off the power for servicing.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
Fans | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | |||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Specifications Met | Each | Each | |||
Open Dripproof Motor Enclosure | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 12" | 1,100 cfm @ 1/2 in. of H₂O 1,300 cfm @ 0 in. of H₂O | 68 dBA @ 5 ft. | 1,625 | 1/3 | 25 1/2" | 25 1/4" | 21" | 50 | 300° | Aluminum | AMCA Certified, ETL Listed | 0000000 | 0000000 | 0000000 | 0000000 |
Totally Enclosed Motor Enclosure | ||||||||||||||||
460V AC, Three Phase—Hardwire | ||||||||||||||||
2 | 12" | 1,150 cfm @ 1/2 in. of H₂O 1,800 cfm @ 0 in. of H₂O | 71 dBA @ 5 ft. | 3,450 | 1/3 | 18" | 26 3/4" | 22" | 44 | 120° | Steel | __ | 0000000 | 00000000 | 00000000 | 000000 |
Direct-Drive Downdraft Roof-Mount Exhaust Fans
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. More economical than upblast roof-mount exhaust fans, these draw stagnant and humid air out through your roof and then direct it back toward the roof. All fans have a disconnect switch to turn off the power for servicing.
Fans with a brushless motor are more efficient than fans with a standard motor. They operate at a wide range of speeds for precise speed control and greater energy savings. They’re also quieter and have a longer lifespan because of their advanced electronic controls.
Note: Airflow depends on the resistance created by ductwork. This resistance, known as static pressure (SP), is measured in inches of water.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mounting Bases | |||||||||||||||
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | Power, hp | Dia. | Ht. | Base Wd. | Wt., lbs. | Max. Ambient Temp., °F | Housing Material | Specifications Met | Each | Each | |||
Totally Enclosed Motor Enclosure | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
1 | 12" | 430 cfm @ 1/2 in. of H₂O 830 cfm @ 0 in. of H₂O | Not Rated | 1,500 | 1/10 | 20 5/16" | 11 3/4" | 19" | 30 | Not Rated | Aluminum | AMCA Certified, ETL Listed | 0000000 | 0000000 | 0000000 | 0000000 |
Totally Enclosed Motor Enclosure—Brushless Motor | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
2 | 12" | 1,000 cfm @ 1/2 in. of H₂O 1,300 cfm @ 0 in. of H₂O | 66 dBA @ 5 ft. | 1,575 | 1/3 | 26 1/4" | 19 1/8" | 21" | 54 | 120° | Aluminum | AMCA Certified, ETL Listed | 0000000 | 000000 | 0000000 | 000000 |
Open Dripproof Motor Enclosure | ||||||||||||||||
120V AC, Single Phase—Hardwire | ||||||||||||||||
2 | 12" | 950 cfm @ 1/2 in. of H₂O 1,250 cfm @ 0 in. of H₂O | 62 dBA @ 5 ft. | 1,625 | 1/4 | 26 1/4" | 19 1/8" | 21" | 53 | Not Rated | Aluminum | AMCA Certified, ETL Listed | 0000000 | 000000 | 0000000 | 000000 |
Hazardous Location Exhaust Fans
These fans have a motor that is UL listed for hazardous environments. Use them to draw stagnant and humid air out of a room or area.
Direct-drive fans have fewer moving parts than belt-drive fans for less maintenance. Add a collar (sold separately) to connect a wall-mount fan these fans to a louver.
For technical drawings and 3-D models, click on a part number.
Fans | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Collars | |||||||||||||||
Blade Dia. | Airflow, cfm | Volume | Drive Type | Motor Speed, rpm | No. of Speeds | Power, hp | Ht. | Wd. | Dp. | Housing Material | Blade Material | Environmental Rating | Each | Each | ||
120/230V AC, Single Phase—Hardwire | ||||||||||||||||
12" | 1,600 | Not Rated | Direct | 1,725 | 1 | 1/4 | 16 1/8" | 16 1/8" | 17 3/4" | Steel | Aluminum | NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G | 0000000 | 000000000 | 0000000 | 0000000 |
Direct-Drive Exhaust Fans
With fewer moving parts than belt-drive fans, these direct-drive exhaust fans require less maintenance. They have a built-in grease pan to collect waste while cooking. Mount these fans directly to your roof with the attached mounting brackets. They meet UL standards for ventilation in residential, commercial, and institutional kitchens.
For technical drawings and 3-D models, click on a part number.
Blade Dia. | Airflow @ Static Pressure | Volume | Motor Speed, rpm | No. of Speeds | Power, hp | Overall Ht. | Base Wd. | Max. Ambient Temp., °F | Housing Material | Blade Material | Features | Specifications Met | Each | |
Totally Enclosed Motor Enclosure | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
120V AC, Single Phase—Hardwire | ||||||||||||||
12" | 1,250 cfm @ 1/2 in. of H₂O 1,500 cfm @ 0 in. of H₂O | 64 dB @ 5 ft. | 1,725 | Variable | 1 | 51 1/8" | 29 1/2" | 350° | Steel | Aluminum | Grease Pan | UL 705, UL 762, ULC-S645, ETL Listed | 0000000 | 000000000 |