Filter by
Surface Fillers
These surface fillers can be used on vertical surfaces without sagging. They repair cracked, worn, and damaged surfaces. The size listed is the combined total of the two parts.
Devcon Aluminum Liquid, Devcon Aluminum Putty, and Devcon FasMetal™ 10 HVAC Repair form a nonrusting finish.
Container | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Size | Type | Begins to Harden, min. | Reaches Full Strength | Consistency | Mix Ratio | Approx. Coverage @ Thick. | Temp. Range, °F | Color | Finishing Method | For Use On | Each | |
Devcon FasMetal™ 10 HVAC Repair | |||||||||||||
19770 | 6.5 fl. oz. | Tube | 60 | 16 hrs. | Paste | 1:1 | 30 sq. in. @ 1/4" | -40° to 250° | Aluminum | Machine, Drill, Sand, Saw, Tap | Aluminum, Steel, Stainless Steel, Ceramic, Concrete, Fiberglass, Wood | 00000000 | 000000 |