We will reply to your message within an hour.
Check the flow rate of liquids up to 200° F from an easy-to-read digital display instead of a scale or dial.
Often used to pinpoint flow issues, these flowmeters clamp onto pipe, so you can spot-check the flow rate at different points without disassembling your system. They measure by tracking the time it takes for ultrasonic waves to pass through your liquid, so they don’t need to come into contact with your liquid.
Using ultrasonic waves, these transmitters measure the flow rate of your liquid from outside your pipe.
Also known as magmeters, these transmitters use a magnetic field to measure flow rate and temperature with high accuracy.
Send flow rate measurements to monitor and control equipment.
Send flow rate and temperature measurements simultaneously to a programmable logic controller (PLC), data logger, or other receiving device.
Send flow rate data using these transmitters while also being able to visually confirm liquid is flowing.
Often used in low-flow metering applications for lubricants or antifreeze, these transmitters measure flow rate and send the data to a remote display or programmable logic controller (PLC).
Thread a ring fitting into your pipe connection and insert the probe of these transmitters to measure the flow and temperature of water, oil, or air.
Commonly referred to as thermal mass flowmeters, these transmitters calculate flow rate by measuring how much they cool as air and other gases pass through them. This means they’re accurate even if there are temperature and pressure changes, unlike most other transmitters.
Measure and transmit flow rate, pressure, and temperature of industrial gases, such as air, argon, CO2, and nitrogen, flowing through your system.
Determine the flow rate and total volume of liquid flowing through your system with the same meter.
Easy to remove for cleaning and maintenance, these flowmeter/totalizers connect to sanitary quick-clamp fittings (often called tri-clamp fittings) and measure the flow rate and volume of liquid passing through your system.
The unthreaded ends of these flowmeter/totalizers install into a PVC piping system, so you can measure the flow rate and volume of liquid passing through your system.
Using the flanged ends, securely install these flowmeter/totalizers in large, high-flow pipelines to measure the flow rate and total volume of liquid flowing through.
Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. They connect to unthreaded PVC pipe.
With one meter, these flowmeter/totalizers measure the flow rate and total flow volume of high-temperature liquid up to 200° F.
Use these flowmeter/totalizers to measure both the flow rate and total flow volume of oil, gasoline, diesel fuel, and kerosene.
A digital display makes it easy to check both the total amount of liquid that’s flowed through and the batch total.
The digital display on these totalizers makes it easy to check the total amount of high-temperature liquid—up to 200° F—passing through your system.
Install this totalizer on your grease gun or valve to measure grease dispensing and reduce waste.
Track batches and the total amount of gasoline, diesel fuel, and kerosene passing through your system.
Measure the amount of light oil that flows through these totalizers.
For monitoring flow at a glance, these switches have a plastic window with a rotor indicator that spins when there’s flow.
Since they come factory set to a specific set point, these switches are easier to install than adjustable flow switches.
Accurate even in applications where pressure fluctuates regularly, these flow switches split flow into two paths and measure their difference in pressure drop to calculate the flow rate of liquid.
Activate or deactivate equipment when your flow rate reaches a set point.
Quicker to install than adjustable flow switches in high-pressure lines, these switches come factory-set to activate or deactivate equipment at a specific level. They compensate for the viscosity and density changes of liquid.
Safe to use where flammable gases and combustible dust may be present, these switches activate or deactivate when your flow reaches a factory-set level. All are UL listed for hazardous environments.
UL listed for use where flammable gases or combustible dusts may be present, these flow switches activate or deactivate equipment when your flow rate reaches a set point.
Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline.
Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate.
Easy to clean and install, these flow switches are 3-A certified to meet sanitary design standards and insert into your line with a quick-clamp mounting adapter. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate.
Easy to install, these flow switches come already set to a specific set point and don’t require you to disassemble your pipeline.
Safely activate and deactivate equipment in environments with flammable gases and combustible dust when your flow rate reaches a set point. These switches save you from disassembling your pipeline because you insert them into pipe tees or pipe outlets instead of mounting them inline.
With a probe on a cord, these meters access hard-to-reach places in duct.
These versatile meters display airflow and one other measurement simultaneously. They’re also known as anemometers or vane meters.
Often used to detect clogged air filters and iced air conditioner coils, these switches sense small changes in pressure between two points in your duct.