Single-Action Electrically Operated Air Directional Control Valves
These valves create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Also known as 3-way and 3/2 valves, they direct airflow from the inlet to your equipment and exhaust return airflow to create motion. In the off position, they exhaust air from the system, allowing equipment to reset so the action can be repeated. Valves without an exhaust connection exhaust air to the atmosphere.
Normally closed valves block airflow until actuated. Valves that are both normally closed and normally open can be installed to block airflow, or allow flow until actuated.
Valves with spring return actuation go back to their original position when voltage is removed. Valves with electric (solenoid) return actuation go back to their original position when voltage is moved from the first solenoid to the second solenoid.
NPTF (Dryseal) threads are compatible with NPT threads.
Manifold-mount valves plug into a manifold (sold separately) to create multiple actions from a single pressure input. Manifolds with multiple exhaust ports have one set of inlet and exhaust ports on each side, so they can be strung together in a series. When using a single manifold, cover the ports on the side you are not using with plugs (sold separately).
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
Valves | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
O'all | Replacement Solenoids | Replacement Solenoid Connectors | ||||||||||||||||
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | Each | Each | ||||
Single Solenoid—Spring Return Actuation | ||||||||||||||||||
A | 3 | 1/8 NPT | 1/8 NPT | Threaded | 24.9 scfm @ 100 psi | 0.75 | 29 to 145 | 4 5/8" | 7/8" | 1 3/8" | Screw In, Manifold | 12V DC | 00000000 | 0000000 | 000000 | 00 | 00000000 | 00000 |
A | 3 | 1/8 NPT | 1/8 NPT | Threaded | 24.9 scfm @ 100 psi | 0.75 | 29 to 145 | 4 5/8" | 7/8" | 1 3/8" | Screw In, Manifold | 24V DC | 00000000 | 000000 | 00000000 | 000000 | 00000000 | 0000 |
A | 3 | 1/8 NPT | 1/8 NPT | Threaded | 24.9 scfm @ 100 psi | 0.75 | 29 to 145 | 4 5/8" | 7/8" | 1 3/8" | Screw In, Manifold | 120V AC | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 0000 |
A | 3 | 1/4 NPT | 1/4 NPT | Threaded | 24.9 scfm @ 100 psi | 1.3 | 29 to 145 | 5 1/2" | 1" | 1 5/8" | Screw In, Manifold | 12V DC | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 0000 |
A | 3 | 1/4 NPT | 1/4 NPT | Threaded | 24.9 scfm @ 100 psi | 1.3 | 29 to 145 | 5 1/2" | 1" | 1 5/8" | Screw In, Manifold | 24V DC | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 0000 |
A | 3 | 1/4 NPT | 1/4 NPT | Threaded | 24.9 scfm @ 100 psi | 1.3 | 29 to 145 | 5 1/2" | 1" | 1 5/8" | Screw In, Manifold | 120V AC | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 0000 |
A | 3 | 3/8 NPTF | 3/8 NPTF | Threaded | 53.1 scfm @ 100 psi | 1.7 | 35 to 150 | 6 1/2" | 1 1/4" | 4 3/4" | Screw In | 12V DC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
A | 3 | 3/8 NPTF | 3/8 NPTF | Threaded | 53.1 scfm @ 100 psi | 1.7 | 35 to 150 | 6 1/2" | 1 1/4" | 4 3/4" | Screw In | 24V DC | 00000000 | 000000 | 00000000 | 00000 | 000000 | 00 |
A | 3 | 3/8 NPTF | 3/8 NPTF | Threaded | 53.1 scfm @ 100 psi | 1.7 | 35 to 150 | 6 1/2" | 1 1/4" | 4 3/4" | Screw In | 120V AC | 0000000 | 000000 | 00000000 | 00000 | 000000 | 00 |
B | 3 | 1/8 NPT | 1/8 NPT | Threaded | 5.6 scfm @ 100 psi | 0.1 | -14.7 to 14.5 | 3 1/4" | 1 5/8" | 3" | Screw In | 24V DC | 00000000 | 00000 | 000000 | 00 | 000000 | 00 |
B | 3 | 1/4 NPT | 1/4 NPT | Threaded | 6 scfm @ 100 psi | 0.11 | -14.7 to 14.5 | 3 1/4" | 1 5/8" | 3" | Screw In | 24V DC | 00000000 | 00000 | 000000 | 00 | 000000 | 00 |
B | 3 | 10-32 UNF | 1/8 NPTF | Threaded | 4.1 scfm @ 100 psi | 0.13 | -14 to 14.5 | 2 11/16" | 15/16" | 2 7/16" | Screw In | 00000000 | 00000 | 000000 | 00 | 000000 | 00 | |
B | 3 | 10-32 UNF | 10-32 UNF | Threaded | 4.1 scfm @ 100 psi | 0.13 | -14 to 14.5 | 2 11/16" | 15/16" | 2 7/16" | Screw In | 00000000 | 00000 | 000000 | 00 | 000000 | 00 | |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 12V DC | 000000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 24V DC | 000000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 24V AC | 000000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 120V AC | 000000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
C | 3 | 1/4 NPT | 1/4 NPT | Threaded | 2.3 scfm @ 100 psi | 0.12 | 0 to 115 | 3" | 7/8" | 2 3/8" | Screw In | 220V AC | 000000000 | 00000 | 000000 | 00 | 000000 | 00 |
C | 3 | 10-32 UNF | 10-32 UNF | Threaded | 27 scfm @ 100 psi | 0.58 | 20 to 125 | 3 3/8" | 3/4" | 2 1/8" | Screw In | 12V DC | 00000000 | 00000 | 000000 | 00 | 000000 | 00 |
C | 3 | 10-32 UNF | 10-32 UNF | Threaded | 27 scfm @ 100 psi | 0.58 | 20 to 125 | 3 3/8" | 3/4" | 2 1/8" | Screw In | 24V DC | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
C | 3 | 10-32 UNF | 10-32 UNF | Threaded | 27 scfm @ 100 psi | 0.58 | 20 to 125 | 3 3/8" | 3/4" | 2 1/8" | Screw In | 110V AC | 00000000 | 00000 | 00000000 | 00000 | 000000 | 00 |
G | 3 | 1/8 NPT | 1/8 NPT | __ | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/8" | Screw In | 12V DC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
G | 3 | 1/8 NPT | 1/8 NPT | __ | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/8" | Screw In | 24V DC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
G | 3 | 1/8 NPT | 1/8 NPT | __ | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/8" | Screw In | 120V AC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
G | 3 | 1/8 NPT | 1/8 NPT | __ | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/8" | Screw In | 240V AC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
G | 3 | 1/4 NPT | 1/4 NPT | __ | 0 scfm @ 0 psi | 0.035 | 0 to 120 | 1 3/4" | 1 1/4" | 2 3/4" | Screw In | 24V DC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
G | 3 | 1/4 NPT | 1/4 NPT | __ | 0 scfm @ 0 psi | 0.035 | 0 to 120 | 1 3/4" | 1 1/4" | 2 3/4" | Screw In | 120V AC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/4" | Screw In | 12V DC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/4" | Screw In | 24V DC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/4" | Screw In | 120V AC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 1.97 scfm @ 100 psi | 0.035 | 0 to 120 | 1 7/8" | 1 1/4" | 2 3/4" | Screw In | 240V AC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
J | 3 | 10-32 UNF | 10-32 UNF | __ | 0.6 scfm @ 100 psi | Not Rated | 0 to 105 | 7/8" | 1 1/4" | 1 5/8" | Screw In | 000000 | 00000 | 000000 | 00 | 000000 | 00 | |
Double Solenoid—Electric (Solenoid) Return Actuation | ||||||||||||||||||
E | 3 | 10-32 UNF | 10-32 UNF | Threaded | 27 scfm @ 100 psi | 0.58 | 20 to 125 | 5" | 3/4" | 2 1/8" | Screw In | 00000000 | 00000 | 000000 | 00 | 000000 | 00 |
Valves | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
O'all | Replacement Solenoids | Replacement Solenoid Connectors | ||||||||||||||||
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | Each | Each | ||||
Single Solenoid—Spring Return Actuation | ||||||||||||||||||
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 0 scfm @ 0 psi | 0.035 | 0 to 120 | 1 3/4" | 1 1/4" | 2 7/8" | Screw In | 24V DC | 00000000 | 0000000 | 0000000 | 000000 | 000000 | 00 |
H | 3 | 1/8 NPT | 1/8 NPT | Threaded | 0 scfm @ 0 psi | 0.035 | 0 to 120 | 1 3/4" | 1 1/4" | 2 7/8" | Screw In | 120V AC | 00000000 | 000000 | 0000000 | 00000 | 000000 | 00 |
H | 3 | 1/4 NPT | 1/4 NPT | Threaded | 0 scfm @ 0 psi | 0.035 | 0 to 120 | 1 3/4" | 1 1/4" | 2 7/8" | Screw In | 24V DC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
H | 3 | 1/4 NPT | 1/4 NPT | Threaded | 0 scfm @ 0 psi | 0.035 | 0 to 120 | 1 3/4" | 1 1/4" | 2 7/8" | Screw In | 120V AC | 00000000 | 000000 | 000000 | 00 | 000000 | 00 |
J | 3 | 10-32 UNF | 10-32 UNF | Threaded | 0.6 scfm @ 100 psi | Not Rated | 0 to 105 | 7/8" | 1 1/4" | 1 7/8" | Screw In | 000000 | 00000 | 000000 | 00 | 000000 | 00 | |
Double Solenoid—Electric (Solenoid) Return Actuation | ||||||||||||||||||
D | 3 | 1/8 NPT | 1/8 NPT | Threaded | 24.9 scfm @ 100 psi | 0.75 | 29 to 145 | 6 1/4" | 7/8" | 1 3/8" | Screw In, Manifold | 00000000 | 000000 | 000000 | 00 | 00000000 | 00000 | |
D | 3 | 1/4 NPT | 1/4 NPT | Threaded | 24.9 scfm @ 100 psi | 1.3 | 29 to 145 | 7 1/16" | 1" | 1 5/8" | Screw In, Manifold | 00000000 | 000000 | 000000 | 00 | 00000000 | 0000 | |
F | 3 | 3/8 NPTF | 3/8 NPTF | Threaded | 53.1 scfm @ 100 psi | 1.7 | 35 to 150 | 8 1/4" | 1 1/4" | 4 3/4" | Screw In | 0000000 | 000000 | 000000 | 00 | 000000 | 00 |
O'all | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | For Inlet Tube OD | For Outlet Tube OD | Exhaust Connection Type | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Lg. | Wd. | Ht. | Mount Type | Choose a Voltage | Each | ||
Single Solenoid—Spring Return Actuation | ||||||||||||||
K | 3 | 5/32" | 5/32" | Push to Connect | 0.6 scfm @ 100 psi | 0.01 | 0 to 120 | 1 3/8" | 5/8" | 1 3/4" | Screw In, Manifold | 0000000 | 000000 | |
K | 3 | 5/32" | 5/32" | Push to Connect | 1.1 scfm @ 100 psi | 0.02 | 0 to 120 | 1 3/8" | 5/8" | 1 3/4" | Screw In, Manifold | 0000000 | 00000 |
No. of | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Stations | Flow Ports | Inlet Ports | Exhaust Ports | For Inlet Tube OD | For Exhaust Tube OD | Lg. | Wd. | Ht. | Mount Type | Mounting Hole Dia. | For DIN Rail Size | Mounting Fasteners Included | Each | |
2 | 2 | 1 | 1 | 1/4" | 5/32" | 2" | 5/8" | 1 7/8" | DIN Rail | 0.69" | 15 mm | No | 00000000 | 000000 |
3 | 2 | 1 | 1 | 1/4" | 5/32" | 2 5/8" | 5/8" | 1 1/4" | DIN Rail | 0.69" | 15 mm | No | 00000000 | 00000 |
4 | 2 | 1 | 1 | 1/4" | 5/32" | 3 1/4" | 5/8" | 1 1/4" | DIN Rail | 0.69" | 15 mm | No | 00000000 | 00000 |
5 | 2 | 1 | 1 | 1/4" | 5/32" | 3 7/8" | 5/8" | 1 1/4" | DIN Rail | 0.69" | 15 mm | No | 00000000 | 00000 |
Tab | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Wire Gauge | Width | Thickness | Insulation Color | Insulation Material | Terminal Material | Maximum Temperature, °F | Maximum Voltage | Pkg. | |
Straight—Single Crimp Female | |||||||||
26-22 | 0.110" | 0.020" | Blue | Nylon Plastic | Tin-Plated Brass | 220 | 600V DC | 0000000 | 00000 |
Fast-Switching Single-Action Electrically Operated Air Directional Control Valves
Run through equipment cycles up to 30% faster than with standard valves. They create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed. Also known as 3-way and 3/2 valves.
Normally open valves allow airflow until actuated. Normally closed valves block airflow until actuated.
Mufflers (sold separately) reduce exhaust noise.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Valves | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Mufflers | ||||||||||||||||
No. of Flow Ports | For Inlet Tube OD, mm | For Outlet Tube OD, mm | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg., mm | Wd., mm | Ht., mm | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | Each | ||
Normally Open Flow Positions | |||||||||||||||||
3 | 4 | 4 | 5.763 | 0.102 | -13 to 116 | 26.5 | 24V DC | 73 | 10 | 34 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 | 0000000 | 000000 |
3 | 8 | 8 | 22.994 | 0.407 | -13 to 116 | 26.5 | 24V DC | 114.6 | 18 | 52 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Normally Closed Flow Positions | |||||||||||||||||
3 | 4 | 4 | 5.763 | 0.102 | -13 to 116 | 26.5 | 24V DC | 73 | 10 | 34 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
3 | 6 | 6 | 11.469 | 0.203 | -13 to 116 | 26.5 | 24V DC | 94.5 | 14 | 45 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
3 | 8 | 8 | 22.994 | 0.407 | -13 to 116 | 26.5 | 24V DC | 114.6 | 18 | 56 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 | 0000000 | 00000 |
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg., mm | Wd., mm | Ht., mm | Mounting Fasteners Included | Environmental Rating | Specifications Met | Each | |
Normally Open Flow Positions | |||||||||||||||
3 | 1/8 BSPP | 1/8 BSPP | 11.469 | 0.203 | -13 to 116 | 26.5 | 24V DC | 34 | 10 | 73 | No | IP65 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 |
Mounting Brackets for Threaded Valves | 0000000 | Each | 00000 |
Single-Action Electrically Operated Air Directional Control Valves with Full Shut-Off
Also known as 3-way and 3/3 valves, these valves close all ports in the off position to stop equipment in a locked position with air pressure holding it in place. They create one action, such as extending a cylinder. Apply voltage to the electrical connection to actuate. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. They're normally closed to block airflow until actuated. Return actuation is by spring, so they go back to their starting position as soon as voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Wire Connection Type | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
Threaded Female Inlet × Threaded Female Outlet | |||||||||||||||
3 | 1/8 NPT | 1/8 NPT | Threaded | 27.36 | 0.59 | 29-102 | 26 | 24V DC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 0000000 |
3 | 1/8 NPT | 1/8 NPT | Threaded | 27.4 | 0.59 | 29-102 | 26 | 120V AC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 000000 |
3 | 1/4 NPT | 1/4 NPT | Threaded | 41.27 | 0.89 | 29-102 | 26 | 24V DC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 000000 |
3 | 1/4 NPT | 1/4 NPT | Threaded | 41.27 | 0.89 | 29-102 | 26 | 120V AC | Solenoid Connectors | 2 1/2" | 1 1/8" | 4 3/8" | Yes | 0000000 | 000000 |
3 | 3/8 NPT | 3/8 NPT | Threaded | 124.0 | 2.2 | 29-102 | 26 | 24V DC | Solenoid Connectors | 3 1/8" | 1 3/8" | 5 3/8" | Yes | 0000000 | 000000 |
3 | 3/8 NPT | 3/8 NPT | Threaded | 124.0 | 2.2 | 29-102 | 26 | 120V AC | Solenoid Connectors | 3 1/8" | 1 3/8" | 5 3/8" | Yes | 0000000 | 000000 |
Robot-Arm-Mounted Electrically Operated Air Directional Control Valves
With two 3-way integrated solenoid valves, these electrically controlled valves direct airflow to end-of-arm tools that don’t require vacuum suction, such as pick-and-place grippers. Also known as 3/2 valves, each of the two solenoid valves directs air to a different port. Use one of the valves for tools that have a single-acting cylinder, or both of the valves for those with a double-acting cylinder. The exhausted air creates the motion to move your tool. These valves are curved and have a foam mounting pad that fits collaborative robot arms. Secure them close to your tools, but out of the way, with the hook-and-loop straps.
These valves have a normally closed starting position, which means airflow is blocked until the valves are actuated. With spring return actuation, they will go back to their original position when the voltage is removed. All of the electrical connections you need are included.
Valves with 90° elbow M8 plug will work with FANUC CRX and Universal Robots models. They include a USB flash drive with software for Universal Robots, called URCap, that plugs into your teach pendant to program the valve.
For technical drawings and 3-D models, click on a part number.
For Tube OD, mm | O'all | With Wire Leads | With 90° Elbow M8 Plug | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Flow Ports | Inlet | Outlet | Max. Flow Rate | Flow Coefficient (Cv) | Pressure Range, psi | Voltage | Lg. | Ht. | Each | For Robot Arm Manufacturer (Series/Model No.) | Each | ||
3/2 Flow Pattern | |||||||||||||
Double Solenoid—Spring Return Actuation | |||||||||||||
3 | 6 | 6 | 2 scfm @ 80 psi | 0.09 | 0-100 | 24V DC | 2" | 2 1/2" | 0000000 | 0000000 | FANUC (CRX 5iA, 10iA, 10iA/L, 20iA/L, 25iA) Universal Robots (UR3; UR3e; UR5; UR5e; UR10; UR10e; UR16; UR16e) | 0000000 | 0000000 |
Washdown-Resistant Electrically Operated Air Directional Control Valves
3-way valves create one action, such as extending a cylinder. Valves with spring return actuation go back to their original position when voltage is removed. Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
O'all | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Directional Control Valve Type | Flow Pattern | No. of Flow Ports | No. of Exhaust Ports | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg. | Wd. | Ht. | Each | |
Single Solenoid—Spring Return Actuation | |||||||||||||
3-Way | 3/2 | 3 | 1 | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 68.58 mm | 0000000 | 0000000 |
O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Air Directional Control Valve Type | Flow Pattern | No. of Flow Ports | No. of Exhaust Ports | For Inlet Tube OD | For Outlet Tube OD | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Voltage | Lg. | Wd. | Ht. | Each | |
SingleSolenoid—Spring Return Actuation | |||||||||||||||
3-Way | 3/2 | 3 | 1 | 8 mm | 8 mm | 25.11 | 0.711 | -13 to 145 | 26.5 | 24V DC | 190.5 mm | 34.9 mm | 76.2 mm | 0000000 | 0000000 |
Modular Air Directional Control Valves with Air Manifolds
Mount valves to a single-station base or to a manifold, which allows a single pressure source for multiple valves, then add or remove valves as your needs change. Valves with the same style can be used on the same manifold. For example, you can put a Style B, 2-position, spring-return valve and a Style B, 3-position, solenoid-return valve on the same manifold.
3-way valves create one action, such as extending a cylinder.
Normally closed valves block airflow until actuated.
Valves with spring return actuation go back to their original position when voltage is removed.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
Valve with
Solenoid Connectors
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Style | No. of Valves | No. of Flow Ports | No. of Flow Positions | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Wire Connection Type | Lg. | Wd. | Ht. | Mounting Fasteners Included | Choose a Voltage | Each | |
3/2 Flow Pattern—Normally Closed Starting Position | |||||||||||||||
Single Solenoid—Spring Return Actuation | |||||||||||||||
A | 1 | 3 | 2 | 5.994 | 0.19 | -14 to 14.5 | 29.9 | Solenoid Connectors | 2 11/16" | 3/4" | 3 1/16" | Yes | 00000000 | 000000 |
Modular Air Directional Control Valves with Air and Electrical Manifolds
Mix and match valve styles on one manifold to meet your control needs. Mount multiple valves to a manifold to reduce piping requirements and create multiple actions from a single pressure input. Add or remove valves as your needs change.
3-way valves create one action, such as extending a cylinder. They have four flow positions, which allows the valve to operate as two independent valves from a single station on the manifold.
Normally closed valves block airflow until actuated.
Valves with air pilot return actuation go back to their starting position when the air supply is moved from the first air pilot to the second air pilot.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Valve Starting Position | No. of Valves | Return Actuation | No. of Flow Ports | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Voltage | Lg. | Wd. | Ht. | Mounting Fasteners Included | Each | |
3/2 Flow Pattern | ||||||||||||||
Normally Closed | 2 | Air Pilot | 3 | 148.41 | 1 | 22-102 | Not Rated | 24V DC | 4 1/16" | 11/16" | 2 3/16" | Yes | 0000000 | 000000 |