About Wire and Cable
More
Outdoor Wire
The EPDM insulation on this wire won’t become brittle or crack from sunlight, humidity, rain, temperature changes, abrasion from dirt and debris, and other rough outdoor conditions. It meets Mine Safety and Health Administration (MSHA) standards for material quality.
SC wire is a good choice for temporary setups powering outdoor lights, equipment, generators, and power distribution boxes, since its thick insulation makes it easy to move and reuse. Commonly found at outdoor events, it’s also known as stage cable.
DLO wire carries higher voltages than SC wire, making it the better choice for heavy duty applications. Use it to run power to motors, cranes, and other equipment in shipyards, mines, and oil- and gas-drilling rigs. Also known as diesel locomotive cable, this wire was originally designed to wire trains. An inner layer of chlorinated polyethylene plastic (CPE) gives it increased resistance to chemicals, heat, and flames. It’s also rated RHW-2, so it can be used underground and in wet locations.
All are flame rated, so they meets requirements for preventing the spread of flames based on a timed test. FT4 wire is mounted to a vertical tray during testing. FT5 wire is suspended horizontally during testing.
- Use for outdoors, buildings, power supply
- Flexible
- Temperature Range: -55° to 220° F
- Insulation: EPDM Rubber
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | Certification | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||
6 | 273/30 | 105 A @ 86° F | 0.47" | Black | SC | UL Listed, CSA Certified, UL 2556 FT5 | MSHA Accepted | 0000000 | 00000 | 00000 | |
4 | 429/30 | 140 A @ 86° F | 0.51" | Black | SC | UL Listed, CSA Certified, UL 2556 FT5 | MSHA Accepted | 0000000 | 0000 | 0000 | |
2 | 676/30 | 190 A @ 86° F | 0.58" | Black | SC | UL Listed, CSA Certified, UL 2556 FT5 | MSHA Accepted | 0000000 | 0000 | 0000 | |
1/0 | 1,042/30 | 260 A @ 86° F | 0.6" | Black | SC | UL Listed, CSA Certified, UL 2556 FT5 | MSHA Accepted | 0000000 | 0000 | 0000 | |
2/0 | 1,316/30 | 300 A @ 86° F | 0.65" | Black | SC | UL Listed, CSA Certified, UL 2556 FT5 | MSHA Accepted | 0000000 | 0000 | 0000 | |
4/0 | 2,062/30 | 405 A @ 86° F | 0.77" | Black | SC | UL Listed, CSA Certified, UL 2556 FT5 | MSHA Accepted | 0000000 | 00000 | 00000 |
- Use for outdoors, buildings, power supply
- Flexible
- Maximum Temperature: 190° F
- Insulation:
Outer: EPDM Rubber
Inner: Chlorinated Polyethylene Plastic, Polyethylene Plastic
Wire Ga. | Current | OD | Outer Insulation Color | Industry Designation | Specifications Met | Certification | 10 ft. Lg. | 25 ft. Lg. | 50 ft. Lg. | 100 ft. Lg. | |
Stranded Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
12 | Not Rated | 0.21" | Black | DLO, RHW-2 | UL Listed, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
10 | Not Rated | 0.27" | Black | DLO, RHW-2 | UL Listed, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
8 | 55 A @ 86° F | 0.33" | Black | DLO, RHW-2 | UL Listed, CSA Certified, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
6 | 75 A @ 86° F | 0.37" | Black | DLO, RHW-2 | UL Listed, CSA Certified, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
4 | 95 A @ 86° F | 0.44" | Black | DLO, RHW-2 | UL Listed, CSA Certified, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
2 | 130 A @ 86° F | 0.5" | Black | DLO, RHW-2 | UL Listed, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
1/0 | 170 A @ 86° F | 0.65" | Black | DLO, RHW-2 | UL Listed, CSA Certified, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
2/0 | 195 A @ 86° F | 0.69" | Black | DLO, RHW-2 | UL Listed, UL 2556 FT4 | MSHA Accepted | 0000000 | ||||
4/0 | 260 A @ 86° F | 0.82" | Black | DLO, RHW-2 | UL Listed, UL 2556 FT4 | MSHA Accepted | 0000000 |
Variable-Frequency Drive Motor Cable
This cable is used in variable-frequency drive motors. It has a layer of braid and foil shielding that provides excellent protection against signal interference caused by voltage fluctuations and current spikes. The industry designation is WTTC, so it can be installed in cable trays or raceway in a wind turbine generator. It’s flame rated FT4 to meet requirements for preventing the spread of flames based on a timed test with material mounted to a vertical tray. The insulation resists oil.
Cable with power wires sends electricity to run a motor. Cable with an uninsulated ground wire has an additional uninsulated ground wire you can use to ground the cable’s foil shielding. Also known as a drain wire, it isn’t counted in the cable’s number of wires. MSHA accepted cable meets Mine Safety and Health Administration (MSHA) standards for material quality.
- Use For: Motors, Interference Shielding
- Flexible
- Temperature Range: -40° to 220° F
- Inner Insulation: Nylon Plastic, PVC Plastic
Power Wire | Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Ga. | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Industry Designation | Features | Certification | Length, ft. | 1-99 | 100-Up | |
Double Shielded—1,000V AC/1,500V DC | |||||||||||||
4 | 18 | 18/4 | 7 A @ 86° F | 0.39" | Black | Black | WTTC | __ | MSHA Accepted | 0000000 | 00000 | 00000 | |
4 | 16 | 16/4 | 10 A @ 86° F | 0.46" | Black | Black, Green/Yellow | WTTC | Uninsulated Ground Wire | MSHA Accepted | 0000000 | 0000 | 0000 |
Flame-Resistant Welding Cable
- Use For: Outdoors, Welding
- Flexible
- Temperature Range: -55° to 190° F
- Insulation: Polyethylene Plastic
This cable meets Mine Safety and Health Administration (MSHA) standards for flame resistance. It’s also flame rated VW-1 to meet requirements for preventing the spread of flames, based on a timed test with vertically suspended material. The insulation resists abrasion and chemicals.