About Electric Motors
When replacing a motor, use the information on your motor’s nameplate to guide your selection.
More
Base-Mount AC Motors


To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
Totally enclosed fan cooled (TEFC) enclosures don’t have vents, so they can be used in damp and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
Overall | Shaft | Insulation | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
230/460 Volts AC, Three Phase | |||||||||||||||
IEC 80M | |||||||||||||||
1 | 1,740 | 3.0/1.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 7 1/8" | 6 1/4" | 3/4" | 1 9/16" | 3 1/8" | F | 311° | IP55 | 00000000 | 000000000 |
Stepper Motors



These stepper motors are good for precise, repetitive movements, such as those made by the head of a 3D printer. Similar to the hands of a clock, their shaft turns in small, equal increments. When the shaft stops, it holds its position even when a counteracting force is applied to the load. You can control the position of the load without having to configure encoders or sensors. All are bipolar hybrid stepper motors, so the current can flow in both directions. This helps them deliver higher torque, precision, and efficiency than unipolar stepper motors.
Motors with 8 wire leads can be connected to a driver in two different ways, so you can choose between more speed or more torque. Depending on your application, you could configure the motor for high torque at low speeds or for low torque at high speeds.
Holding torque is the force needed to move the shaft out of position when it is stationary. When the shaft is in motion, torque generally decreases as speed increases. Use a torque-speed curve to confirm which motor will work for your application. Click on a part number and select “Product Detail” to view the curve for a motor.
Full step increment is the rotation of the shaft from one position to the next. A smaller full step increment means the rotor has more teeth, producing smoother and more precise motion. 1.8° is considered standard.
All motors require a controller and driver (not included).
For technical drawings and 3-D models, click on a part number.
O'all | Shaft | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Holding Torque, in.-oz. | Max. Speed, rpm | Max. Current per Phase, A | Full Step Increment | No. of Wire Leads | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Type | No. of Shafts | Temp. Range, °F | Each | |
Square Body | |||||||||||||||
NEMA 42 | |||||||||||||||
3,155.4 | 225 | 12 | 1.8° | 8 | 8.1" | 4.3" | 4.3" | 3/4" | 2 1/8" | 2.17" | Keyed | 1 | 0° to 120° | 00000000 | 0000000 |
4,531.5 | 160 | 16 | 1.8° | 8 | 10.1" | 4.3" | 4.3" | 3/4" | 2 1/8" | 2.17" | Keyed | 1 | 0° to 120° | 00000000 | 000000 |
DC Gearmotors



Convert speed to torque to get the power you need—gearmotors are a motor and speed reducer in one. You can wire for clockwise or counterclockwise rotation; instructions are included. Gearmotors transmit motion inline with the motor.
To control motor speed, motor controls are also available. To convert AC power to DC power, see AC to DC transformers.
For technical drawings and 3-D models, click on a part number.
Gearmotors | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Shaft | Insulation | Replacement Motor Brushes | ||||||||||||||
Power, hp | Speed @ Continuous Operating Torque | Radial Load Capacity, lbs. | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., ° F | Each | Pkg. Qty. | Pkg. | ||
90 Volts DC | |||||||||||||||||
1/20 | 0.9 rpm @ 711 in.-lbs. | 900 | 0.23 | Totally Enclosed Fan Cooled (TEFC) | 12" | 5" | 6 1/4" | 3/4" | 2" | 4 1/2" | F | 311° | 0000000 | 000000000 | 2 | 000000000 | 000000 |
Each | Each | ||||||||||||||||
1/4 | 42 rpm @ 280 in.-lbs. | 327 | 2.3 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 | __ | 000000000 | 00000 |
1/4 | 62 rpm @ 220 in.-lbs. | 303 | 2.3 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 | __ | 000000000 | 00000 |
1/4 | 83 rpm @ 155 in.-lbs. | 267 | 2.3 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 | __ | 000000000 | 00000 |
1/4 | 110 rpm @ 100 in.-lbs. | 256 | 2 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 | __ | 000000000 | 00000 |
1/4 | 165 rpm @ 70 in.-lbs. | 232 | 2 | Totally Enclosed Nonventilated (TENV) | 13 1/4" | 6" | 5 1/2" | 3/4" | 1 5/8" | 4" | F | 311° | 0000000 | 000000 | __ | 000000000 | 00000 |
Each | Pkg. | ||||||||||||||||
1/2 | 17 rpm @ 1,112 in.-lbs. | 700 | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 | 1 | 000000000 | 00000 |
1/2 | 30 rpm @ 822 in.-lbs. | 650 | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 | 1 | 000000000 | 00000 |
1/2 | 39 rpm @ 705 in.-lbs. | 650 | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 | 1 | 000000000 | 00000 |
1/2 | 57 rpm @ 476 in.-lbs. | 625 | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 | 1 | 000000000 | 00000 |
1/2 | 84 rpm @ 320 in.-lbs. | 575 | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/2" | 8 1/4" | 6 1/2" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 000000 | 1 | 000000000 | 00000 |
1/2 | 210 rpm @ 210 in.-lbs. | 525 | 5 | Totally Enclosed Fan Cooled (TEFC) | 16 1/4" | 8 1/4" | 6 3/4" | 3/4" | 1 1/2" | 3" | F | 311° | 0000000 | 00000000 | 1 | 000000000 | 00000 |
Washdown DC Gearmotors



Rated IP55 with an epoxy-coated enclosure, these gearmotors drive low-speed, high-torque applications in areas that are subject to low-pressure washdowns. They combine a motor with a speed reducer to lower speeds while increasing torque. Since their shaft is parallel to the motor, they transmit motion inline with the motor. They have a TENV (totally enclosed nonventilated) enclosure that is similar to a TEFC (totally enclosed fan cooled) enclosure, except it doesn't have a fan. It relies on cooling from the air circulation created by the motor's motion instead.
You can wire the shaft to rotate clockwise or counterclockwise; instructions are included.
For technical drawings and 3-D models, click on a part number.
Gearmotors | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Shaft | Insulation | Replacement Motor Brushes | |||||||||||||
Power | Speed @ Continuous Operating Torque | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | Each | ||
90 Volts DC | ||||||||||||||||
1/8 hp | 14 rpm @ 341 in.-lbs. | 1.5 | Totally Enclosed Nonventilated (TENV) | 11 3/4" | 6" | 6 3/4" | 3/4" | 1 5/8" | 4" | F | 311° | IP55 | 0000000 | 000000000 | 000000000 | 000000 |
1/4 hp | 42 rpm @ 280 in.-lbs. | 2.6 | Totally Enclosed Nonventilated (TENV) | 13 3/4" | 6" | 6 3/4" | 3/4" | 1 5/8" | 4" | F | 311° | IP55 | 0000000 | 00000000 | 000000000 | 00000 |
1/4 hp | 500 rpm @ 25 in.-lbs. | 2.4 | Totally Enclosed Nonventilated (TENV) | 13 3/4" | 6" | 6 3/4" | 3/4" | 1 5/8" | 4" | F | 311° | IP55 | 00000000 | 00000000 | 000000000 | 00000 |
AC Gearmotors

Turn speed into torque with these AC-powered gearmotors—they combine a motor and a speed reducer into one. You can wire them for clockwise or counterclockwise rotation; instructions are included. The parallel shaft transmits motion inline with the motor.
Base-mount motors come with a base, so they can be secured to a flat surface. Base/face-mount motors give you the flexibility to mount directly onto equipment or to the included base.
TEFC (totally enclosed fan cooled) motors have an enclosure to protect them from dirt, dust, and moisture. An external fan blows air on the enclosure to keep them cool. 230/460V AC motors are inverter-rated, so you can adjust the speed with a motor speed control (not included).
For technical drawings and 3-D models, click on a part number.


Overall | Shaft | Insulation | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Gear Type | Bearing Type | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
115/230 Volts AC, Single Phase | |||||||||||||||||
1/4 | 12 rpm @ 1,030 in.-lbs. | 5.4/2.7 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/2" | 8 1/4" | 7 3/4" | Helical and Spur | Ball | 3/4" | 1 1/2" | 3" | B | 266° | IP43 | 0000000 | 000000000 |
1/4 | 26 rpm @ 569 in.-lbs. | 5.4/2.7 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/2" | 8 1/4" | 7 3/4" | Helical and Spur | Ball | 3/4" | 1 1/2" | 3" | B | 266° | IP43 | 0000000 | 00000000 |
1/2 | 22 rpm @ 1,105 in.-lbs. | 8.8/4.4 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 8 1/4" | 7 3/4" | Helical and Spur | Ball | 3/4" | 1 1/2" | 3" | F | 311° | IP43 | 0000000 | 00000000 |
1/2 | 59 rpm @ 496 in.-lbs. | 8.8/4.4 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 8 1/4" | 7 3/4" | Helical and Spur | Ball | 3/4" | 1 1/2" | 3" | F | 311° | IP43 | 0000000 | 00000000 |
1/2 | 91 rpm @ 336 in.-lbs. | 8.8/4.4 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 8 1/4" | 7 3/4" | Helical and Spur | Ball | 3/4" | 1 1/2" | 3" | F | 311° | IP43 | 0000000 | 00000000 |
1/2 | 133 rpm @ 229 in.-lbs. | 8.8/4.4 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 8 1/4" | 7 3/4" | Helical and Spur | Ball | 3/4" | 1 1/2" | 3" | F | 311° | IP43 | 0000000 | 00000000 |
230/460 Volts AC, Three Phase | |||||||||||||||||
1/4 | 38 rpm @ 400 in.-lbs. | 1.04/0.52 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/4 | 53 rpm @ 285 in.-lbs. | 1.04/0.52 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/4 | 73 rpm @ 205 in.-lbs. | 1.04/0.52 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/4 | 100 rpm @ 150 in.-lbs. | 1.04/0.52 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/4 | 148 rpm @ 106 in.-lbs. | 1.04/0.52 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/4 | 294 rpm @ 44 in.-lbs. | 1.04/0.52 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/2 | 54 rpm @ 575 in.-lbs. | 1.83/0.91 | Yes | Totally Enclosed Fan Cooled (TEFC) | 15 1/4" | 5 1/2" | 7 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/2 | 75 rpm @ 415 in.-lbs. | 1.83/0.91 | Yes | Totally Enclosed Fan Cooled (TEFC) | 15 1/4" | 5 1/2" | 7 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/2 | 102 rpm @ 310 in.-lbs. | 1.83/0.91 | Yes | Totally Enclosed Fan Cooled (TEFC) | 15 1/4" | 5 1/2" | 7 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/2 | 151 rpm @ 205 in.-lbs. | 1.83/0.91 | Yes | Totally Enclosed Fan Cooled (TEFC) | 15 1/4" | 5 1/2" | 7 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1/2 | 300 rpm @ 106 in.-lbs. | 1.83/0.91 | Yes | Totally Enclosed Fan Cooled (TEFC) | 15 1/4" | 5 1/2" | 7 3/4" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1 | 153 rpm @ 415 in.-lbs. | 3.1/1.56 | Yes | Totally Enclosed Fan Cooled (TEFC) | 17 1/2" | 5 3/4" | 8" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |
1 | 304 rpm @ 210 in.-lbs. | 3.1/1.56 | Yes | Totally Enclosed Fan Cooled (TEFC) | 17 1/2" | 5 3/4" | 8" | Helical | Roller | 3/4" | 1 1/2" | 2.95" | F | 311° | IP54 | 0000000 | 000000 |


Overall | Shaft | Insulation | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Gear Type | Bearing Type | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
115/230 Volts AC, Single Phase | |||||||||||||||||
1/4 | 47 rpm @ 294 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 0000000 |
1/4 | 88 rpm @ 163 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |
1/4 | 113 rpm @ 128 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |
1/4 | 159 rpm @ 91 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |
1/4 | 338 rpm @ 41 in.-lbs. | 2.35/1.25 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 7" | 5 1/4" | Helical and Spur | Ball and Roller | 3/4" | 1 1/2" | 3.56" | B | 266° | IP44 | 0000000 | 000000 |
Washdown Right-Angle AC Gearmotors



Run high-torque, low speed applications in cramped areas that are frequently hosed down. To save space, these transmit motion at a 90° angle from the the body of the motor, so they're positioned alongside equipment when mounted. They’re rated IP66 for protection from dust and water, and have a drain that allows internal condensation to escape, preventing corrosion. These TEFC (totally enclosed fan cooled) motors have an external fan that keeps them cool.
They’re inverter rated, so you can use them with a motor speed control (not included) to adjust the motor speed. Wire motors for clockwise or counterclockwise rotation; instructions are included.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp, °F | Environmental Rating | Each | |
Left Side Shaft Location | ||||||||||||||
230/460 Volts AC | ||||||||||||||
1/2 | 93 rpm @ 335 in.-lbs. | 1.83/0.91 | Totally Enclosed Fan Cooled (TEFC) | 15 3/8" | 6 1/4" | 7 1/2" | 3/4" | 1 1/2" | 2" | F | 311° | IP66 | 0000000 | 000000000 |
1/2 | 146 rpm @ 210 in.-lbs. | 1.83/0.91 | Totally Enclosed Fan Cooled (TEFC) | 15 1/2" | 6 1/4" | 7 1/2" | 3/4" | 1 1/2" | 2" | F | 311° | IP66 | 0000000 | 00000000 |
1 | 111 rpm @ 575 in.-lbs. | 3.1/1.56 | Totally Enclosed Fan Cooled (TEFC) | 17 3/4" | 6 1/2" | 8" | 3/4" | 1 1/2" | 2" | F | 311° | IP66 | 0000000 | 00000000 |
Right Side Shaft Location | ||||||||||||||
230/460 Volts AC | ||||||||||||||
1/2 | 93 rpm @ 335 in.-lbs. | 1.83/0.91 | Totally Enclosed Fan Cooled (TEFC) | 15 3/8" | 6 1/4" | 7 1/2" | 3/4" | 1 1/2" | 2" | F | 311° | IP66 | 0000000 | 00000000 |
1/2 | 146 rpm @ 210 in.-lbs. | 1.83/0.91 | Totally Enclosed Fan Cooled (TEFC) | 15 1/2" | 6 1/4" | 7 1/2" | 3/4" | 1 1/2" | 2" | F | 311° | IP66 | 0000000 | 00000000 |
1 | 111 rpm @ 575 in.-lbs. | 3.1/1.56 | Totally Enclosed Fan Cooled (TEFC) | 17 3/4" | 6 1/2" | 8" | 3/4" | 1 1/2" | 2" | F | 311° | IP66 | 0000000 | 00000000 |
Washdown AC Gearmotors
IP rated, these gearmotors stand up to high-pressure washdowns. They combine a motor with a speed reducer to lower speed while increasing torque. Their parallel shaft transmits motion inline with the motor.
Since they’re inverter-rated, you can adjust the speed with a motor speed control (not included). Wire these motors for clockwise or counterclockwise rotation; instructions are included.
Base-mount motors come with a base, so they can be secured to a flat surface. Face-mount motors bolt directly to your equipment. They require a power cord (sold separately).
TEFC (totally enclosed fan cooled) enclosures protect against dirt, dust, and moisture. An external fan blows air on the enclosure to keep it cool. TENV (totally enclosed non-ventilated) enclosures are similar to TEFC enclosures, except they don’t have a fan. They rely on air circulation from the motion of the motor for cooling.
Motors rated IP66 have a labyrinth drain plug that keeps water out while letting condensation escape. Motors rated IP69K protect against dust, debris, and high-temperature washdowns.
For technical drawings and 3-D models, click on a part number.



Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max Temp., °F | Environmental Rating | Each | |
230/460 Volts AC—Base Mount | ||||||||||||||
1/4 | 30 rpm @ 515 in.-lbs. | 1.04/0.52 | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 0000000 |
1/4 | 38 rpm @ 400 in.-lbs. | 1.04/0.52 | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |
1/4 | 53 rpm @ 285 in.-lbs. | 1.04/0.52 | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |
1/4 | 73 rpm @ 205 in.-lbs. | 1.04/0.52 | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |
1/4 | 100 rpm @ 150 in.-lbs. | 1.04/0.52 | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |
1/4 | 148 rpm @ 106 in.-lbs. | 1.04/0.52 | Totally Enclosed Fan Cooled (TEFC) | 14 1/2" | 5 1/2" | 6 3/4" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |
1/2 | 54 rpm @ 575 in.-lbs. | 1.83/0.91 | Totally Enclosed Fan Cooled (TEFC) | 15 1/2" | 5 1/2" | 7 1/2" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |
1/2 | 75 rpm @ 415 in.-lbs. | 1.83/0.91 | Totally Enclosed Fan Cooled (TEFC) | 15 1/2" | 5 1/2" | 7 1/2" | 3/4" | 1 5/8" | 2.95" | F | 311° | IP66 | 0000000 | 000000 |



Overall | Shaft | Insulation | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed @ Continuous Operating Torque | Full Load Current, A | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max Temp., °F | Environmental Rating | Each | |
230 Volts AC—Face Mount | ||||||||||||||
1/8 | 7 rpm @ 500 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 000000000 |
1/8 | 12 rpm @ 500 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 00000000 |
1/8 | 24 rpm @ 256 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 00000000 |
1/8 | 47 rpm @ 128 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 00000000 |
1/8 | 91 rpm @ 70 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 00000000 |
1/8 | 178 rpm @ 34 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 00000000 |
1/8 | 347 rpm @ 16 in.-lbs. | 0.5 | Totally Enclosed Nonventilated (TENV) | 10 3/4" | 5 1/4" | 5 1/4" | 3/4" | 1 5/8" | 3.45" | F | 311° | IP69K | 0000000 | 00000000 |
Right-Angle AC Gearmotors



A motor and speed reducer in one, these gearmotors have hypoid gears for energy-efficient operation. You can use them to turn a shaft on your equipment or add a keyed shaft (sold separately). Wire for clockwise or counterclockwise rotation; instructions are included. Gearmotors meet IP54 for protection from dust and splashed water. They're inverter rated so you can use them with a motor speed control (not included) to adjust the motor speed.
For technical drawings and 3-D models, click on a part number.
Gearmotors | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Output | Optional Keyed Shafts with Key Stock | |||||||||||
Power, hp | Speed @ Continuous Operating Torque | Radial Load Cap., lbs. | Full Load Current, A | Lg. | Wd. | Ht. | For Shaft Dia. | Shaft Center to Base | Environmental Rating | Each | Each | ||
230 Volts AC, Three Phase | |||||||||||||
1/15 | 7 rpm @ 470 in.-lbs. | 725 | 0.39 | 13" | 4" | 6 1/8" | 3/4" | 1.91" | IP54 | 0000000 | 000000000 | 0000000 | 000000 |
1/8 | 14 rpm @ 440 in.-lbs. | 550 | 0.63 | 14 3/4" | 4" | 6 1/8" | 3/4" | 1.91" | IP54 | 0000000 | 00000000 | 0000000 | 00000 |
1/8 | 28 rpm @ 220 in.-lbs. | 455 | 0.63 | 14 3/4" | 4" | 6 1/8" | 3/4" | 1.91" | IP54 | 0000000 | 00000000 | 0000000 | 00000 |
1/8 | 56 rpm @ 105 in.-lbs. | 370 | 0.63 | 14 3/4" | 4" | 6 1/8" | 3/4" | 1.91" | IP54 | 0000000 | 00000000 | 0000000 | 00000 |
1/8 | 84 rpm @ 73 in.-lbs. | 330 | 0.63 | 14 3/4" | 4" | 6 1/8" | 3/4" | 1.91" | IP54 | 0000000 | 00000000 | 0000000 | 00000 |
1/8 | 168 rpm @ 35 in.-lbs. | 270 | 0.63 | 14 3/4" | 4" | 6 1/8" | 3/4" | 1.91" | IP54 | 0000000 | 00000000 | 0000000 | 00000 |
Speed-Control AC Gearmotors




Start, stop, reverse direction, and control the speed of these gearmotors from the mounted keypad. Because you can fine tune output speed and direction, these gearmotors are often used in material processing and handling applications, such as controlling the speed of a mixer or conveyor. These gearmotors are both a motor and speed reducer in one to lower speed while increasing torque. All transmit motion inline with the motor. Secure them to flat surfaces with the base mount. These gearmotors have a TEFC (totally enclosed fan cooled) enclosure that protects better than ODP (open drip proof) enclosures. They are not airtight but can be used in dirty, dusty, and damp environments. To keep the motor cool, they have an external fan that blows air over the outside of the motor.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed Range @ Continuous Operating Torque | Full Load Current, A | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Environmental Rating | Each | |
240 Volts AC, Three Phase | |||||||||||
1/2 | 8.8 rpm to 53 rpm @ 585 in.-lbs. | 1.9 | 15 3/4" | 8" | 10 1/4" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 000000000 |
1/2 | 24 rpm to 148 rpm @ 210 in.-lbs. | 1.9 | 15 3/4" | 8" | 10 1/4" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1/2 | 49 rpm to 295 rpm @ 106 in.-lbs. | 1.9 | 15 3/4" | 8" | 10 1/4" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1 | 24 rpm to 148 rpm @ 425 in.-lbs. | 3.5 | 17 3/4" | 8 1/4" | 10 1/2" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1 | 49 rpm to 295 rpm @ 210 in.-lbs. | 3.5 | 17 3/4" | 8 1/4" | 10 1/2" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
460 Volts AC, Three Phase | |||||||||||
1/2 | 8.8 rpm to 53 rpm @ 585 in.-lbs. | 1.1 | 15 3/4" | 8" | 10 1/4" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1/2 | 24 rpm to 148 rpm @ 210 in.-lbs. | 1.1 | 15 3/4" | 8" | 10 1/4" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1/2 | 49 rpm to 295 rpm @ 106 in.-lbs. | 1.1 | 15 3/4" | 8" | 10 1/4" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1 | 24 rpm to 148 rpm @ 425 in.-lbs. | 1.7 | 17 3/4" | 8 1/4" | 10 1/2" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
1 | 49 rpm to 295 rpm @ 210 in.-lbs. | 1.7 | 17 3/4" | 8 1/4" | 10 1/2" | 3/4" | 1 1/2" | 3" | IP54 | 0000000 | 00000000 |
Speed-Control Right-Angle AC Gearmotors




A good solution for tight spaces, these gearmotors let you control the start, stop, rotation direction, and speed while transmitting motion at a 90° angle from the motor, so you can mount them alongside your application. They combine a motor with a speed reducer to lower speed while increasing torque. All have a mounted keypad to make changes to the integrated speed control. Mount them to flat surfaces using their base. These gearmotors have a TEFC (totally enclosed fan cooled) enclosure that protects better than an ODP (open dripproof) enclosure. They aren’t airtight, but they can be used in dirty, dusty, and damp environments. To keep the motor cool, the enclosure has an external fan that blows air over the outside of the motor.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Speed Range @ Continuous Operating Torque | Full Load Current, A | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Environmental Rating | Each | |
Left-Hand Output Shaft | |||||||||||
240 Volts AC, Three Phase | |||||||||||
1/2 | 24 rpm to 144 rpm @ 220 in.-lbs. | 1.9 | 16" | 9" | 10" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 000000000 |
1 | 24 rpm to 144 rpm @ 445 in.-lbs. | 3.5 | 18" | 9" | 10 1/2" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |
460 Volts AC, Three Phase | |||||||||||
1/2 | 13 rpm to 77 rpm @ 405 in.-lbs. | 1.1 | 16" | 9" | 10" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |
1 | 18 rpm to 107 rpm @ 595 in.-lbs. | 1.7 | 18" | 9" | 10 1/2" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |
Right-Hand Output Shaft | |||||||||||
240 Volts AC, Three Phase | |||||||||||
1/2 | 24 rpm to 144 rpm @ 220 in.-lbs. | 1.9 | 16" | 8 1/2" | 10" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |
1 | 24 rpm to 144 rpm @ 445 in.-lbs. | 3.5 | 18" | 8 1/2" | 10 1/2" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |
460 Volts AC, Three Phase | |||||||||||
1/2 | 13 rpm to 77 rpm @ 405 in.-lbs. | 1.1 | 16" | 8 1/2" | 10" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |
1 | 18 rpm to 107 rpm @ 595 in.-lbs. | 1.7 | 18" | 8 1/2" | 10 1/2" | 3/4" | 1 5/8" | 1.97" | IP54 | 0000000 | 00000000 |