About Electric Motors
When replacing a motor, use the information on your motor’s nameplate to guide your selection.
More
U.S.-Made Face-Mount AC Motors
Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Also known as C-face motors, they bolt directly to gearboxes, pumps, and other machinery. They’re more compact than base-mount motors and the direct, rigid connection to your equipment helps keep them aligned. Rated for continuous duty, they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
Open drip proof (ODP) enclosures have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
Totally enclosed fan cooled (TEFC) enclosures don’t have vents, so they can be used in damp and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure. Totally enclosed non-ventilated (TENV) enclosures are similar to TEFC enclosures, but they don’t have a fan, so they’re more compact and easier to maintain. However, the motor gets warmer and runs less efficiently than it would with a fan to cool it.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Insulation Max. Temp., °F | Each | |
115/208/230 Volts AC, Single Phase | |||||||||||||
NEMA 56C | |||||||||||||
1/3 | 3,450 | 6.0/3.2/3.0 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 7 1/2" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 0000000 |
2 | 3,450 | 23.0/12.0/11.5 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 5/8" | 311° | 00000000 | 00000000 |
115/230 Volts AC, Single Phase | |||||||||||||
NEMA 56C | |||||||||||||
1/4 | 1,725 | 2.6/1.3 | No | Open Dripproof (ODP) | 12" | 8 1/4" | 8 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/4 | 1,725 | 5.0/2.5 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 7 1/2" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/3 | 1,725 | 6.0/3.0 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 7 1/2" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/3 | 1,740 | 3.4/1.7 | No | Open Dripproof (ODP) | 12" | 8 1/4" | 8 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/2 | 1,725 | 4.7/2.3 | No | Open Dripproof (ODP) | 12 3/4" | 8 1/4" | 8 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/2 | 1,725 | 7.4/3.7 | No | Totally Enclosed Fan Cooled (TEFC) | 12" | 8 1/2" | 7 1/2" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/2 | 3,450 | 4.9/2.5 | No | Open Dripproof (ODP) | 12" | 8 1/4" | 8 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/2 | 3,450 | 7.0/3.5 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 8 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
3/4 | 1,725 | 8.4/4.2 | No | Totally Enclosed Fan Cooled (TEFC) | 12 1/2" | 8 1/2" | 8 1/4" | 5/8" | 1 7/8" | 3" | 311° | 00000000 | 000000 |
3/4 | 3,450 | 9.6/4.8 | No | Totally Enclosed Fan Cooled (TEFC) | 12" | 8 1/2" | 8 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1 | 1,725 | 12.5/6.3 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 5/8" | 311° | 00000000 | 000000 |
1 | 1,750 | 8.8/4.4 | No | Open Dripproof (ODP) | 13 1/4" | 9 1/4" | 9" | 5/8" | 1 7/8" | 3 3/8" | 311° | 00000000 | 00000000 |
1 | 3,450 | 11.8/5.9 | No | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 5/8" | 266° | 00000000 | 000000 |
1 1/2 | 1,725 | 12.2/6.1 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 9" | 5/8" | 1 7/8" | 3 3/8" | 311° | 00000000 | 000000 |
1 1/2 | 3,450 | 16.0/8.0 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 5/8" | 266° | 00000000 | 000000 |
208/230/460 Volts AC, Three Phase | |||||||||||||
NEMA 56C | |||||||||||||
1/3 | 1,725 | 1.5/1.4/0.7 | No | Totally Enclosed Nonventilated (TENV) | 10 1/4" | 8 1/4" | 6" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/2 | 1,720 | 1.7/1.6/0.8 | No | Totally Enclosed Nonventilated (TENV) | 10 1/4" | 8 1/4" | 6" | 5/8" | 1 7/8" | 3" | 311° | 00000000 | 000000 |
1/2 | 1,725 | 1.7/1.6/0.8 | No | Open Dripproof (ODP) | 12 3/4" | 8 1/4" | 6 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
3/4 | 1,725 | 3.2/3.0/1.5 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
230/460 Volts AC, Three Phase | |||||||||||||
NEMA 56C | |||||||||||||
1/4 | 1,735 | 1.2/0.6 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/3 | 1,725 | 1.4/0.7 | No | Open Dripproof (ODP) | 11 1/4" | 8 1/4" | 6 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1/2 | 3,450 | 1.6/0.8 | No | Open Dripproof (ODP) | 11 1/4" | 8 1/4" | 6 1/4" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
3/4 | 1,730 | 2.2/1.1 | No | Open Dripproof (ODP) | 12 1/4" | 9 1/4" | 7" | 5/8" | 1 7/8" | 3 3/8" | 311° | 00000000 | 000000 |
3/4 | 3,450 | 2.6/1.3 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6" | 5/8" | 1 7/8" | 3" | 266° | 00000000 | 000000 |
1 | 1,750 | 3.2/1.6 | No | Open Dripproof (ODP) | 12 1/4" | 9 1/4" | 7" | 5/8" | 1 7/8" | 3 3/8" | 311° | 00000000 | 000000 |
1 | 1,760 | 3.2/1.6 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 8 7/8" | 6 7/8" | 5/8" | 1 7/8" | 3 1/4" | 311° | 00000000 | 000000 |
1 | 3,450 | 2.8/1.4 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 8 7/8" | 6 7/8" | 5/8" | 1 7/8" | 3 1/4" | 311° | 00000000 | 000000 |
1 1/2 | 1,760 | 4.6/2.3 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 5/8" | 311° | 00000000 | 00000000 |
1 1/2 | 3,500 | 3.8/1.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 8 7/8" | 6 7/8" | 5/8" | 1 7/8" | 3 1/4" | 311° | 00000000 | 000000 |
2 | 1,760 | 5.6/2.8 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 5/8" | 311° | 00000000 | 00000000 |
2 | 3,490 | 5.0/2.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 8 7/8" | 6 7/8" | 5/8" | 1 7/8" | 3 1/4" | 311° | 00000000 | 00000000 |
U.S.-Made Base/Face-Mount AC Motors
Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Whether you’re switching between jobs or need flexibility during installation, these motors give you a variety of mounting options. Mount the feet to a flat surface or bolt the face directly to a gearbox, pump, or other machinery. You can also do both at once for added stability in applications with high loads or vibration. More compact than our standard NEMA-frame motors, these motors fit better in tight spots. They’re rated for continuous duty, so they’re often used for equipment that requires constant power, such as fans, pumps, and conveyors.
When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
Totally enclosed fan cooled (TEFC) enclosures don’t have vents, so they can be used in damp and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure. Totally enclosed non-ventilated (TENV) enclosures are similar to TEFC enclosures, but they don’t have a fan, so they’re more compact and easier to maintain. However, the motor gets warmer and runs less efficiently than it would with a fan to cool it.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
115/208/230 Volts AC, Single Phase | |||||||||||||||
NEMA 56C | |||||||||||||||
1/3 | 1,725 | 6.0/3.6/3.0 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 8" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | __ | 00000000 | 0000000 |
1/2 | 1,725 | 7.4/4.1/3.7 | No | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 000000 |
1/2 | 1,725 | 7.4/4.3/3.7 | No | Totally Enclosed Fan Cooled (TEFC) | 12" | 8 1/2" | 8" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | __ | 00000000 | 000000 |
1/2 | 3,450 | 7.0/4.1/3.5 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | __ | 00000000 | 000000 |
3/4 | 1,725 | 8.4/5.4/4.2 | No | Totally Enclosed Fan Cooled (TEFC) | 12 1/2" | 8 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | __ | 00000000 | 000000 |
3/4 | 1,725 | 11.0/7.0/5.5 | No | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 000000 |
1 | 1,725 | 12.8/7.0/6.4 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | __ | 00000000 | 000000 |
1 | 1,725 | 12.8/7.0/6.4 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 00000000 |
1 | 3,450 | 11.8/6.1/5.9 | No | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | __ | 00000000 | 000000 |
1 1/2 | 1,725 | 12.4/6.8/6.2 | No | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 00000000 |
1 1/2 | 3,450 | 15.0/7.9/7.5 | No | Totally Enclosed Fan Cooled (TEFC) | 13 1/4" | 9 1/2" | 9 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | __ | 00000000 | 000000 |
208/230/460 Volts AC, Three Phase | |||||||||||||||
NEMA 56C | |||||||||||||||
1/3 | 1,725 | 1.9/1.6/0.8 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6 3/4" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | __ | 00000000 | 000000 |
1/2 | 1,740 | 1.8/1.6/0.8 | No | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 000000 |
3/4 | 1,725 | 3.2/3.0/1.5 | No | Totally Enclosed Fan Cooled (TEFC) | 11 1/2" | 8 1/2" | 6 3/4" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | __ | 00000000 | 000000 |
3/4 | 1,750 | 3.0/2.8/1.4 | No | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 000000 |
230/460 Volts AC, Three Phase | |||||||||||||||
NEMA 56C | |||||||||||||||
1/2 | 1,740 | 2.0/1.0 | No | Totally Enclosed Nonventilated (TENV) | 11 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | __ | 00000000 | 000000 |
1 | 1,745 | 2.9/1.5 | Yes | Totally Enclosed Nonventilated (TENV) | 12 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 00000000 |
1 | 1,760 | 3.0/1.5 | Yes | Totally Enclosed Fan Cooled (TEFC) | 12 1/4" | 9 1/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | __ | 00000000 | 00000000 |
2 | 1,755 | 5.8/2.9 | Yes | Totally Enclosed Fan Cooled (TEFC) | 14 1/4" | 9 1/2" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP55 | 00000000 | 00000000 |
Base/Face-Mount AC Brake Motors
When these motors lose power, a brake engages to hold your equipment’s position, unlike standard AC motors. They’re often used with conveyors to keep items in place after a power loss, and with hoists to stop them from dropping a load. Mount them from the base or face. Rated for continuous duty, these motors can run equipment that never turns off. Their shaft is keyed, and they come with key stock. These motors have a TEFC (totally enclosed fan cooled) enclosure that protects better than an ODP (open dripproof) enclosure. They aren’t airtight, but they can be used in dirty, dusty, and damp environments. To keep the motor cool, the enclosure has an external fan that blows air over the outside of the motor.
For technical drawings and 3-D models, click on a part number.
O'all | Shaft | Insulation | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
230/460 Volts AC, Three Phase | |||||||||||||||
NEMA 56C | |||||||||||||||
3/4 | 1,720 | 2.8/1.4 | No | Totally Enclosed Fan Cooled (TEFC) | 15 1/4" | 8 3/4" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | IP43 | 0000000 | 000000000 |
1 | 1,760 | 3.2/1.6 | Yes | Totally Enclosed Fan Cooled (TEFC) | 17 1/4" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP43 | 0000000 | 00000000 |
Face-Mount AC Brake Motors
A built-in brake engages to hold your equipment in place when these motors lose power, unlike standard AC motors. These motors are often used with conveyors to keep items in place after a power loss, and with hoists to prevent them from dropping a load. Also known as C-face motors, these bolt directly to your equipment. They’re rated for continuous duty, so they can run equipment that never turns off. Their shaft is keyed, and they come with a key stock. These motors have a TEFC (totally enclosed fan cooled) enclosure that protects better than an ODP (open dripproof) enclosure. They’re not airtight, but they can be used in dirty, damp, and dusty environments. To keep the motor cool, the enclosure has an external fan that blows air over the outside of the motor.
For technical drawings and 3-D models, click on a part number.
O'all | Shaft | Insulation | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Motor Enclosure Type | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Class | Max. Temp., °F | Environmental Rating | Each | |
230/460 Volts AC, Three Phase | |||||||||||||||
NEMA 56C | |||||||||||||||
3/4 | 1,720 | 2.8/1.4 | No | Totally Enclosed Fan Cooled (TEFC) | 15 3/8" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | B | 266° | IP54 | 0000000 | 000000000 |
1 | 1,760 | 3.2/1.6 | Yes | Totally Enclosed Fan Cooled (TEFC) | 17 1/4" | 8 7/8" | 7 1/4" | 5/8" | 1 7/8" | 3 1/2" | F | 311° | IP43 | 0000000 | 00000000 |
Sanitary Washdown Base/Face-Mount AC Motors
For versatility in food and sanitary lines, these motors mount by their feet or bolt directly to equipment to power pumps and other machines. Many features make them safe for sanitary and washdown environments: Smooth contours and a laser-marked nameplate limit where bacteria could grow. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they stand up to hot spraying water, chemicals, and harsh cleaners often used in food plants. A two-barrier seal on the shaft stops water from getting in. If water does seep in, drain plugs let it out.
Rated for continuous duty, these motors run equipment that never turns off. They’re also inverter rated, so they work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. The conduit box also rotates, so there’s no need to reroute power when connecting conduit.
TEFC (totally enclosed fan cooled) motors have a fan that cools the housing.
TENV (totally enclosed nonventilated) motors don’t need a fan or ventilation. They have even fewer places for water and contaminants to get in than TEFC motors.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | Torque @ 460V AC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Shaft Type | Class | Max. Temp., °F | Starting Torque, in.-lbs. | Continuous Operating Torque, in.-lbs. | Environmental Rating | Each | |
208/230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1/2 | 1,800 | 1.9/1.8/0.9 | Yes | 11 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 356° | 61.1 | 17.9 | IP69 | 0000000 | 000000000 |
230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) | |||||||||||||||||
2 | 3,600 | 5.0/2.5 | Yes | 14 7/8" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 356° | 165.6 | 35.9 | IP69 | 0000000 | 00000000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
3/4 | 1,800 | 2.2/1.1 | Yes | 12 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 356° | 97.2 | 26.9 | IP69 | 0000000 | 00000000 |
1 | 1,800 | 3.0/1.5 | Yes | 12 3/4" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 356° | 114 | 36 | IP69 | 0000000 | 00000000 |
1 1/2 | 3,600 | 3.6/1.8 | Yes | 13 5/8" | 9 3/4" | 6 3/4" | 5/8" | 2" | 3 1/2" | Keyed | H | 356° | 122.4 | 27.7 | IP69 | 0000000 | 00000000 |
Sanitary Washdown Face-Mount AC Motors
Bolt these motors directly to conveyors and other machines to power equipment on food and sanitary lines. They help you meet Good Manufacturing Practices (GMP) since they have many features that make them safe for sanitary and washdown environments. Smooth contours and a laser-marked nameplate limit the space where bacteria could grow. They don’t have feet, so they’re easy to rinse down thoroughly. A stainless steel enclosure, epoxy resin lined interior, and IP69 rating mean they withstand hot spraying water, harsh cleaners, and sanitizers common to food plants. A two-barrier seal keeps water from getting in through the shaft. If water does seep in, drain plugs let it out.
These motors are also called C-face motors. They’re rated for continuous duty, so they’ll run equipment that never turns off. Inverter rated, they also work with variable frequency drive (VFD) to run at different speeds. You can wire for clockwise or counterclockwise rotation; instructions are included. Their conduit box also rotates to connect conduit from any side without needing to reroute power.
TEFC (totally enclosed fan cooled) motors have a fan that cools the housing.
TENV (totally enclosed nonventilated) motors don’t need a fan or ventilation. They have even fewer places for water and contaminants to get in than TEFC motors.
For technical drawings and 3-D models, click on a part number.
Overall | Shaft | Insulation | Torque @ 460V AC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Power, hp | Max. Speed, rpm | Full Load Current, A | Inverter Rated | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Shaft Type | Class | Max. Temp., °F | Starting Torque, in.-lbs. | Continuous Operating Torque, in.-lbs. | Environmental Rating | Each | |
208/230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
1/2 | 1,800 | 1.9/1.8/0.9 | No | 13" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 356° | 61 | 17.8 | IP69 | 0000000 | 000000000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box | |||||||||||||||||
3/4 | 3,600 | 2.1/2.0/1.0 | Yes | 11 3/4" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 356° | 56.8 | 13.5 | IP69 | 0000000 | 00000000 |
230/460 Volts AC, Three Phase | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) with Rotatable Conduit Box | |||||||||||||||||
3/4 | 1,800 | 2.6/1.3 | Yes | 14" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 356° | 96.1 | 26.8 | IP69 | 0000000 | 00000000 |
2 | 1,800 | 5.6/2.8 | Yes | 14" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 356° | 208 | 72.1 | IP69 | 0000000 | 00000000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) with Rotatable Conduit Box | |||||||||||||||||
1 | 3,600 | 2.8/1.4 | No | 11 3/4" | 9 7/8" | 6 1/2" | 5/8" | 1 7/8" | 3 1/4" | Keyed | H | 356° | 96.1 | 18.2 | IP69 | 0000000 | 00000000 |
1 1/2 | 3,600 | 3.6/1.8 | Yes | 13 3/4" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 356° | 122.4 | 27.7 | IP69 | 0000000 | 00000000 |
2 | 3,600 | 4.8/2.4 | No | 15" | 9 7/8" | 6 1/2" | 5/8" | 2" | 3 1/4" | Keyed | H | 356° | 165.6 | 35.8 | IP69 | 0000000 | 00000000 |
Base/Face-Mount DC Motors
With two location options for any-angle mounting, you can put these motors to work in a variety of equipment configurations. Motors are rated for continuous duty and have a keyed shaft that comes with key stock. Wire for clockwise or counterclockwise rotation; instructions are included.
Use a motor speed control (not included) to adjust motor speed. Use an AC to DC transformer (not included) to convert AC power to DC power.
For technical drawings and 3-D models, click on a part number.
Motors | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Shaft | Insulation | Replacement Motor Brushes | ||||||||||||||
Power, hp | Speed @ Continuous Operating Torque | Max. Speed, rpm | Starting Torque, in.-lbs. | Full Load Current, A | Lg. | Wd. | Ht. | Dia. | Lg. | Center to Base | Base Type | Class | Max. Temp., ° F | Each | Pkg. | ||
90V DC | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) | |||||||||||||||||
3/4 | 1,750 rpm @ 27 in.-lbs. | 1,935 | 236.9 | 7.6 | 14 3/4" | 6 3/4" | 7 1/2" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000000 | 00000000 | 000000 |
1 | 1,750 rpm @ 36 in.-lbs. | 1,853 | 528.4 | 10 | 15 1/2" | 6 3/4" | 7 1/2" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 00000000 | 00000000 | 00000 |
1 | 2,500 rpm @ 25.2 in.-lbs. | 2,699 | 490.2 | 9.7 | 14 3/4" | 6 3/4" | 7 1/2" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 00000000 | 00000000 | 00000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1/4 | 1,750 rpm @ 9 in.-lbs. | 1,863 | 89.33 | 2.5 | 12 1/4" | 6 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |
1/3 | 1,750 rpm @ 12 in.-lbs. | 1,783 | 144.3 | 3.2 | 13 1/4" | 6 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |
1/2 | 1,750 rpm @ 18 in.-lbs. | 1,853 | 150.92 | 4.8 | 15" | 6 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |
1/2 | 2,500 rpm @ 12.6 in.-lbs. | 2,526 | 343.88 | 5 | 13 1/4" | 6 1/2" | 8 1/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |
180V DC | |||||||||||||||||
NEMA 56C—Totally Enclosed Fan Cooled (TEFC) | |||||||||||||||||
3/4 | 1,750 rpm @ 27 in.-lbs. | 1,985 | 350.3 | 3.7 | 14 3/4" | 6 3/4" | 7 1/2" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 00000000 | 00000000 | 00000 |
1 | 1,750 rpm @ 36.6 in.-lbs. | 1,870 | 485.6 | 5 | 15 1/2" | 6 3/4" | 7 1/2" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 00000000 | 00000000 | 00000 |
NEMA 56C—Totally Enclosed Nonventilated (TENV) | |||||||||||||||||
1/4 | 1,750 rpm @ 9 in.-lbs. | 1,830 | 103.3 | 1.3 | 12 1/4" | 6 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |
1/3 | 1,750 rpm @ 15.2 in.-lbs. | 1,800 | 285.9 | 1.6 | 13 1/4" | 6 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |
1/2 | 1,750 rpm @ 18 in.-lbs. | 1,880 | 509.2 | 2.5 | 15" | 6 1/2" | 8 3/4" | 5/8" | 1 7/8" | 3 1/2" | Removable | F | 311° | 0000000 | 000000 | 00000000 | 00000 |