How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Constant-Flow-Rate Pumps for Oil
A high-horsepower motor moves oil with a viscosity similar to SAE 60 motor oil. Also known as gear pumps, these produce a smooth flow of liquid to lubricate equipment and blend oils. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. Products cannot be sold outside North America due to restrictions.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
5 | 880 | -20° to 240° | 1/2 | 2/1 | 1/2 | NPT | Female | 1/2 | NPT | Female | 21 5/8" | 6 7/8" | 8 1/2" | Outside North America | 00000000 | 000000000 |
208-240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
10 | 880 | -20° to 240° | 2 | 6.2/3.1 | 3/4 | NPT | Female | 3/4 | NPT | Female | 24" | 6 7/8" | 8 1/2" | Outside North America | 00000000 | 00000000 |
20 | 880 | -20° to 240° | 2 | 6.2/3.1 | 1 | NPT | Female | 1 | NPT | Female | 24 1/2" | 6 7/8" | 8 1/2" | Outside North America | 00000000 | 00000000 |
30 | 880 | -20° to 240° | 3 | 8.2/4.1 | 1 | NPT | Female | 1 | NPT | Female | 25" | 6 7/8" | 8 1/2" | Outside North America | 00000000 | 00000000 |
40 | 880 | -20° to 240° | 5 | 13.8/6.9 | 1 1/2 | NPT | Female | 1 1/2 | NPT | Female | 28 1/8" | 11 7/8" | 8 1/2" | Outside North America | 00000000 | 00000000 |
Constant-Flow-Rate Pumps for Water
Also known as gear pumps, these produce a smooth flow of liquid for applications such as cooling engines, powering hydraulic equipment, and extracting liquid from holding tanks. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward. Do not use with solids. Pumps can be used in dusty, dirty, and damp environments.
Pumps that cannot be sold to Canada are restricted by local energy efficiency requirements.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake (NPT) | Discharge (NPT) | Overall | Chemical Resistance | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Motor Enclosure Type | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | |
115/230V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
2.1 | 150 | 100,000 | 32° to 140° | 1/2 | 7.4/3.7 | 1/4 | Female | 1/4 | Female | Totally Enclosed | 16 1/16" | 8 3/16" | 8" | __ | 0000000 | 000000000 |
8.5 | 150 | 100,000 | 32° to 140° | 1 | 12.8/6.4 | 1/2 | Female | 1/2 | Female | Totally Enclosed | 18 1/8" | 9 3/16" | 9" | __ | 0000000 | 00000000 |
230/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
10.2 | 150 | 100,000 | 32° to 140° | 1 1/2 | 4.4/2.2 | 1/2 | Female | 1/2 | Female | Totally Enclosed Fan Cooled | 19 13/16" | 9 5/16" | 7 1/4" | Canada | 0000000 | 00000000 |
23 | 150 | 100,000 | 32° to 140° | 3 | 8.4/4.2 | 1 | Female | 1 | Female | Totally Enclosed Fan Cooled | 25 1/8" | 10 5/16" | 9 1/16" | Canada | 0000000 | 00000000 |
Harsh-Environment Compact Constant-Flow-Rate Pumps for Water and Oil
An aluminum enclosure around the motor provides protection in dusty and dirty environments. Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
12V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 2.2 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 000000 |
24V DC—Without Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.61 gpm (78 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.4 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4" | 1 3/4" | 2 1/2" | 0000000 | 000000 |
Compact Constant-Flow-Rate Pumps for Water and Oil
Designed to fit into small equipment, these pumps have miniature gears and a subfractional horsepower motor for low-flow applications. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.43 gpm (55 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.5 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4 3/8" | 3" | 3 3/4" | 0000000 | 0000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.43 gpm (55 oz./min.) | 20 | 800 | 10° to 180° | Subfractional | 1.5 | Barbed | Male | 3/16" | Barbed | Male | 3/16" | 4 3/8" | 3" | 3 3/4" | 0000000 | 000000 |
Any-Direction Constant-Flow-Rate Pumps for Water
Mount these pumps in any position, even upside down. Pumps have a subfractional horsepower motor rated for intermittent use (return to room temperature before restarting). Also known as diaphragm pumps, they are for use in low-flow spraying, draining, and washdown applications. They are self-priming, which means they create a suction force to draw liquid upward. Pumps can run dry and do not require an initial fill, so they’re a good choice for applications without a constant flow of liquid. Do not use with solids.
Battery-operated pumps operate on a 12-volt battery. They are commonly used with agricultural sprayers and washers.
Pumps with a pressure switch automatically shut off the pump at the maximum pressure.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ Pressure | Max. ft. of Head | Max. Pressure, psi | Max. Temp., °F | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Max. Self-Priming Ht., ft. | Lg. | Wd. | Ht. | Each | ||
120V AC, Single Phase—With Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
A | 1.5 | 1.24 gpm @ 20 psi (46 ft. of head), 1.04 gpm @ 60 psi (138 ft. of head) | 346 | 150 | 170° | 1 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 9 3/8" | 3 3/8" | 4 1/8" | 0000000 | 0000000 |
Plug | ||||||||||||||||||
A | 1.4 | 1.15 gpm @ 20 psi (46 ft. of head), 0.84 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 130° | 0.57 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 7 5/8" | 3 3/8" | 4 1/4" | 0000000 | 000000 |
A | 1.6 | 1.32 gpm @ 20 psi (46 ft. of head), 1.07 gpm @ 60 psi (138 ft. of head) | 231 | 100 | 170° | 0.95 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 8 5/8" | 3 3/8" | 4" | 0000000 | 000000 |
A | 1.7 | 1.52 gpm @ 20 psi (46 ft. of head), 0.03 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 170° | 0.61 | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 | 8 5/8" | 3 3/8" | 4" | 0000000 | 000000 |
A | 3 | 2.20 gpm @ 20 psi (46 ft. of head) | 104 | 45 | 120° | 0.7 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 8 3/4" | 5" | 4 1/2" | 0000000 | 000000 |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug | ||||||||||||||||||
A | 3.4 | 2.30 gpm @ 20 psi (46 ft. of head) | 92 | 40 | 120° | 1 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 7 5/8" | 5" | 4 3/8" | 0000000 | 000000 |
12V DC—With Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
B | 5.3 | 4.30 gpm @ 20 psi (46 ft. of head), 3.40 gpm @ 60 psi (138 ft. of head) | 120 | 60 | 140° | 17 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 10" | 4 15/16" | 4" | 0000000 | 000000 |
12V DC—Without Thermal Overload Protection and With Pressure Switch | ||||||||||||||||||
Hardwire | ||||||||||||||||||
A | 1.8 | 1.45 gpm @ 20 psi (46 ft. of head), 1.22 gpm @ 60 psi (138 ft. of head) | 231 | 100 | 170° | 8.7 | 3/8 | NPT | Female | 3/8 | NPT | Female | 10 | 8 3/8" | 4" | 4 1/8" | 0000000 | 000000 |
A | 1.8 | 1.57 gpm @ 20 psi (46 ft. of head), 1.23 gpm @ 60 psi (138 ft. of head) | 138 | 60 | 170° | 7.2 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12 | 8 3/8" | 4" | 4 1/8" | 0000000 | 000000 |
A | 3 | 2.69 gpm @ 20 psi (46 ft. of head) | 115 | 50 | 170° | 8 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 8 | 8 5/8" | 5" | 4 1/2" | 0000000 | 000000 |
A | 3.5 | 2.56 gpm @ 20 psi (46 ft. of head) | 115 | 50 | 130° | 9.9 | 1/2 | NPSM | Male | 1/2 | NPSM | Male | 9 | 8 5/8" | 5" | 4 1/2" | 0000000 | 000000 |
Continuous-Duty Any-Direction Constant-Flow-Rate Pumps for Water and Coolants
Rated for continuous use, this pump is often used to move caustics such as antifreeze and salt water. Mount it in any position, even upside down. Also known as a diaphragm pump, it is typically used for low-flow spraying, draining, and washdown applications. Pump has a pressure switch that automatically shuts off the pump at the maximum pressure. It is self-priming, which means it creates a suction force to draw liquid upward. Pump can run dry and does not require an initial fill, so it’s a good choice for applications without a constant flow of liquid. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Flow Rate @ Pressure | Max. Pressure, psi | Max. Viscosity, cP | Max. Temp. Range, °F | hp | Current, A | Tube Connection Type | Gender | For Tube ID | Tube Connection Type | Gender | For Tube ID | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection and Pressure Switch | |||||||||||||||||
Plug | |||||||||||||||||
3 | 2.50 gpm @ 20 psi (46 ft. of head) | 40 | 250 | 130° | 3/16 | 1.8 | Barbed | Male | 1/2" | Barbed | Male | 1/2" | 10 7/8" | 5 3/8" | 5 5/8" | 0000000 | 0000000 |
High-Pressure Constant-Flow-Rate Pumps
Commonly called rotary vane pumps, these are designed to pump water at high pressures in low-flow applications. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. They have a built-in bypass relief valve to prevent pressure buildup. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | hp | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
0.8 | 240 | Not Rated | 30° to 195° | 1/4 | 5 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 0000000 |
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Hardwire | ||||||||||||||||
1.8 | 240 | Not Rated | 30° to 195° | 1/3 | 5.6/2.8 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 000000 |
2.3 | 240 | Not Rated | 30° to 195° | 1/2 | 7.2/3.6 | 3/8 | NPT | Female | 3/8 | NPT | Female | 12" | 6" | 6" | 00000000 | 000000 |
Constant-Flow-Rate Pumps without Motor for Water
These pumps have a bronze housing and gears for use with water. Select your own motor to tailor them to your application. Use a NEMA 56C frame electric motor with a coupling and belt/pulley drive. Also known as gear pumps, they produce a smooth flow of liquid for water delivery. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Required hp | Intake | Discharge | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Flow Rate @ 25 psi, gpm | Max. Ft. of Head, ft. | Max. Viscosity, cP | @ 25 psi | @ 100 psi | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Ctr.-to-Base Lg. | Each | |
For 1,725 rpm Max. Motor Speed | |||||||||||||||||||
2.1 | 1.8 | 345 | 17,300 | 1/8 | 1/4 | 1/4 | NPT | Female | 1/4 | NPT | Female | 6 3/16" | 2 1/2" | 3" | 1/2" | 1 13/16" | 1 7/8" | 000000 | 0000000 |
4.2 | 4 | 345 | 17,300 | 1/4 | 1/2 | 1/4 | NPT | Female | 1/4 | NPT | Female | 5 3/4" | 3" | 3 11/16" | 1/2" | 1 13/16" | 2 3/8" | 0000000 | 000000 |
10.6 | 10.2 | 345 | 17,300 | 3/4 | 1 3/4 | 1/2 | NPT | Female | 1/2 | NPT | Female | 6 7/8" | 3 3/4" | 4 1/4" | 5/8" | 2" | 2 3/4" | 0000000 | 000000 |
19.8 | 19 | 345 | 17,300 | 1 1/2 | 2 3/4 | 3/4 | NPT | Female | 3/4 | NPT | Female | 7 1/16" | 4 3/8" | 5 1/4" | 5/8" | 2 3/16" | 3 9/16" | 0000000 | 000000 |
23.5 | 22.2 | 345 | 17,300 | 1 1/2 | 2 3/4 | 1 | NPT | Female | 1 | NPT | Female | 7 5/16" | 4 5/16" | 5 1/4" | 5/8" | 2 3/16" | 3 9/16" | 0000000 | 000000 |
For 1,750 rpm Max. Motor Speed | |||||||||||||||||||
7.2 | 7 | 345 | 17,300 | 3/4 | 1 1/2 | 3/8 | NPT | Female | 3/8 | NPT | Female | 6 9/16" | 3 3/4" | 4 1/4" | 5/8" | 2 1/16" | 2 3/4" | 0000000 | 000000 |
Constant-Flow-Rate Pumps without Motor for Oil
A cast iron housing and steel gears allow these pumps to be used to dispense oil and fuel such as hydraulic oil and diesel fuel. Select your own motor to tailor them to your application. Use an air or electric motor with a coupling and belt/pulley drive. Also known as gear pumps, they produce a smooth flow of liquid for applications such as engine lubrication. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Required hp | Intake | Discharge | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 25 psi, gpm | Max. Flow Rate, gpm | Max. ft. of Head | Max. Viscosity, cP | @ 25 psi | @ 100 psi | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Center-to-Base Lg. | Each | |
8.9 | 9 | 462 | 20,000 | 3/4 | 1 | 1/2 | NPT | Female | 1/2 | NPT | Female | 7 1/4" | 3 7/16" | 4 1/2" | 5/8" | 1 9/16" | 3" | 00000000 | 000000000 |
Constant-Flow-Rate Pumps without Motor for Chemicals
With a 316 stainless steel housing and stainless steel gears, these pumps are often used to dispense chemicals such as ethylene glycol, isopropyl alcohol, and nitric acid. Use an electric motor with a coupling and belt/pulley drive. Also known as gear pumps, they produce a smooth flow of liquid. All are self-priming, which means they create a suction force to draw liquid upward and fill the pump chamber. Do not use with solids.
For technical drawings and 3-D models, click on a part number.
Required hp | Intake (NPT) | Discharge (NPT) | Overall | Shaft | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 25 psi, gpm | Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | @ 25 psi | @ 100 psi | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Dia. | Lg. | Center-to-Base Lg. | Each | |
4.3 | 4 | 346.3 | 150 | 20,000 | 1/4 | 3/4 | 1/2 | Female | 1/2 | Female | 6 1/4" | 3" | 3 3/4" | 1/2" | 1 1/4" | 2 5/8" | 00000000 | 000000000 |
10.2 | 10 | 346.3 | 150 | 20,000 | 1/2 | 1 1/2 hp | 3/4 | Female | 3/4 | Female | 7 1/2" | 3 3/8" | 4 3/8" | 5/8" | 1 3/4" | 3" | 00000000 | 00000000 |
High-Pressure Constant-Flow-Rate Pumps without Motor for Water
Commonly called rotary vane pumps, they have a built-in bypass relief valve to prevent pressure buildup. Attach an electric motor with a speed reducer or a belt pulley to alter the pump speed. Use a NEMA 56C frame motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids. They meet NSF/ANSI 61 safety standards for use with drinking water systems.
Pumps with a 303 stainless steel housing are more corrosion resistant than pumps with a brass housing.
Intake (NPT) | Discharge (NPT) | Overall | Shaft | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity | For Motor Power Source | Required hp | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Lg. | Wd. | Dp. | Center-to-Base Lg. | Each | |
Brass Housing | ||||||||||||||||||
0.8 | 554 | 240 | Not Rated | Electric | 1/4 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 0000000 |
1.8 | 554 | 240 | Not Rated | Electric | 1/3 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
2.3 | 554 | 240 | Not Rated | Electric | 1/2 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
4.3 | 554 | 240 | Not Rated | Electric | 3/4 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
5.4 | 554 | 240 | Not Rated | Electric | 1 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
303 Stainless Steel Housing | ||||||||||||||||||
2.3 | 554 | 240 | Not Rated | Electric | 1/2 | 3/8 | Female | 3/8 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
4.3 | 554 | 240 | Not Rated | Electric | 3/4 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
5.4 | 554 | 240 | Not Rated | Electric | 1 | 1/2 | Female | 1/2 | Female | 7" | 7" | 6" | 7/16" | 1/4" | 3/8" | 3" | 00000000 | 000000 |
High-Pressure Constant-Flow-Rate Pumps without Motor for Pressure Washing
Also known as plunger pumps, these can provide pressures up to 3,000 psi. Use them for washdowns, drain jetting, and other pressurized water-spraying applications. Connect them directly to an electric motor to alter the pump speed. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
For technical drawings and 3-D models, click on a part number.
Intake | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Pressure, psi | Temp. Range, °F | Required hp | For NEMA Frame | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Lg. | Wd. | Ht. | For Shaft Dia. | Each | |
2 | 2,000 | -20° to 160° | 2.7 | 56C | 3/8 | NPT | Female | 3/8 | NPT | Female | 8 1/4" | 8 5/8" | 6 1/2" | 5/8" | 00000000 | 0000000 |
3 | 3,000 | -20° to 140° | 6 1/5 | 182TC, 184TC | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 1/2" | 9 1/4" | 7 1/8" | 1 1/8" | 00000000 | 000000 |
4 | 2,000 | -20° to 140° | 5 1/2 | 182TC, 184TC | 1/2 | NPT | Female | 3/8 | NPT | Female | 9 1/2" | 9 1/4" | 7 1/8" | 1 1/8" | 00000000 | 000000 |
Self-Priming Circulation Pumps without Motor for Oil
Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Intake (NPT) | Discharge (NPT) | Shaft | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Gender | Pipe Size | Gender | Pipe Size | Dia. | Lg. | Ctr.-to-Base Lg. | Ht. | Lg. | Wd. | Each | |
For 500 rpm-2,100 rpm Motor Speed | |||||||||||||||||
11.5 | 50 | 21 | Not Rated | 50° to 180° | 1/3 hp | Female | 1/2 | Female | 1/2 | 5/8" | 1 1/8" | 1 15/16" | 3 13/16" | 4 1/2" | 4 1/8" | 0000000 | 0000000 |
25 | 50 | 26 | Not Rated | 50° to 180° | 3/4 hp | Female | 1 | Female | 1 | 5/8" | 2 1/4" | 1 7/8" | 3 9/16" | 6 3/8" | 4 3/4" | 0000000 | 000000 |
Self-Priming Circulation Pumps without Motor for Water
Also known as flexible impeller pumps, these create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Intake (NPT) | Discharge (NPT) | Overall | Shaft | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Gender | Pipe Size | Gender | Pipe Size | Ht. | Lg. | Wd. | Dia. | Lg. | Ctr.-to-Base Lg. | Each | |
For 500 rpm-2,100 rpm Motor Speed | |||||||||||||||||
13 | 60 | 26 | Not Rated | 50° to 180° | 1/3 | Female | 1/2 | Female | 1/2 | 3 13/16" | 4 1/2" | 4 1/8" | 5/8" | 1 1/8" | 1 15/16" | 0000000 | 0000000 |
27.9 | 60 | 26 | Not Rated | 50° to 180° | 3/4 | Female | 1 | Female | 1 | 3 9/16" | 6 3/8" | 4 3/4" | 5/8" | 2 1/4" | 1 7/8" | 0000000 | 000000 |
Harsh-Environment Self-Priming Water-Removal Pumps
This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||
Plug with 8 ft. Cord | |||||||||||||
5 4/5 | 30 | 1/4" | 125 | 60° to 180° | 1/4 hp | 4.2 | 1/2 NPT Female, 3/4 GHT Male | 1/2 NPT Female, 3/4 GHT Male | 9" | 5 5/8" | 7 3/8" | 0000000 | 0000000 |