About Sump, Water-Removal, Condensate, and Submersible Pumps
More
About Process Pumps
More
About Drum Pumps
More
Electric Drum Pumps for Water, Oil, and Chemicals
Drain and transfer liquid more quickly and easily than hand-operated pumps and siphon pumps.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Container Size, gal. | Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower, hp | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
1-5 | 7, 17 | 8 | 300 | 0° | 150° | 0.15 | 2 | 1 1/2" | 1 1/4" | 16" | 3/4" | 1" | 60" | Plug | 0000000 | 0000000 |
30 | 7, 17 | 8 | 300 | 0° | 150° | 0.15 | 2 | 1 1/2" | 1 1/4" | 40" | 3/4" | 1" | 60" | Plug | 0000000 | 000000 |
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Intake | Discharge | Maintenance Parts | |||||||||||||||
For Container Size, gal. | Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Max. Temp., °F | Horsepower, hp | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Electrical Connection Type | Each | ||
120V AC, Single Phase | |||||||||||||||||
55 | 17 | 7 | 1,000 | 180° | 1/2 | 6.3 | 2 NPT | Drum Connector | 1 1/2" | 39 1/2" | 1" | 1 1/4" | 60" | Plug | 0000000 | 0000000 | 0000000 |
Hazardous Location Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
These pumps quickly empty drum contents by moving 48 gallons of liquid per minute. They are often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions. Their electric motors are explosion proof and UL listed for Class I, Divisions 1 and 2, Groups C and D; and Class II, Division 2, Groups F and G environments where flammable gases and combustible dust may be present.
Pumps | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Maintenance Parts | |||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Thermal Protection | Each | ||
120V AC, Single Phase | ||||||||||||||||
Hardwire | ||||||||||||||||
48.5 | 14 | 55 | 300 | -40° | 210° | 1/2 hp | 5.3 | 41 mm | 1 5/8" | 39" | Barbed | 1" | With Thermal Overload Protection | 00000000 | 000000000 | 00000000 |
Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Repair Parts | |||||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Electrical Connection Type | Each | |||
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
A | 0-18.5 | 9 | 30 | 15° | 120° | 1/4 hp | 1.5 | 32 mm | Wall Bracket | 1 1/4" | 27" | 3/4" | 1" | 60" | Plug | 00000000 | 0000000 | 00000000 |
A | 0-18.5 | 9 | 55 | 15° | 120° | 1/4 hp | 1.5 | 32 mm | Wall Bracket | 1 1/4" | 39" | 3/4" | 1" | 60" | Plug | 00000000 | 000000 | 00000000 |
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Intake | Discharge | Optional Drum Connectors | Repair Parts | ||||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Temp. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube Connection Type | For Tube ID | Electrical Connection Type | Each | Each | ||||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
B | 0-35 | 16 | 55 | 130° | 1 hp | 8.5 | 2" | 1 5/8" | 39" | Barbed | 1" | Plug | 0000000 | 000000000 | 0000000 | 000000 | 0000000 |
B | 0-35 | 16 | 55 | 130° | 1 hp | 8.5 | 2" | 1 5/8" | 47" | Barbed | 1" | Plug | 0000000 | 00000000 | 0000000 | 00000 | 0000000 |
B | 0-35 | 16 | 55 | 175° | 1 hp | 8.5 | 2" | 1 1/2" | 39" | Barbed | 1" | Plug | 0000000 | 00000000 | 0000000 | 000000 | 0000000 |
B | 0-35 | 16 | 55 | 175° | 1 hp | 8.5 | 2" | 1 1/2" | 47" | Barbed | 1" | Plug | 0000000 | 00000000 | 0000000 | 000000 | 0000000 |
B | 0-35 | 16 | 55 | 175° | 1 hp | 8.5 | 2" | 1 5/8" | 39" | Barbed | 1" | Plug | 0000000 | 00000000 | 0000000 | 00000 | 0000000 |
High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals
Designed to move 40 gallons of liquid per minute, these pumps quickly empty drum contents. They're often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Temp. Range, °F | Intake | Discharge | Repair Parts | ||||||||||||||
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | ||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
40 | 35 | 30 | 500 | 35° | 160° | 1/2 hp | 5.7 | 2 NPT | Drum Connector | 2" | 27" | 1" | 1 5/16" | 60" | 0000000 | 000000000 | 0000000 |
40 | 35 | 55 | 500 | -20° | 220° | 1/2 hp | 5.7 | 2 NPT | Drum Connector | 2" | 40" | 1" | 1 5/16" | 60" | 0000000 | 00000000 | 0000000 |
40 | 35 | 55 | 500 | -20° | 220° | 1/2 hp | 5.7 | 2 NPT | Drum Connector | 2" | 48" | 1" | 1 5/16" | 60" | 0000000 | 00000000 | 0000000 |
40 | 35 | 55 | 500 | 35° | 160° | 1/2 hp | 5.7 | 2 NPT | Drum Connector | 2" | 40" | 1" | 1 5/16" | 60" | 0000000 | 00000000 | 0000000 |
40 | 35 | 55 | 500 | 35° | 160° | 1/2 hp | 5.7 | 2 NPT | Drum Connector | 2" | 48" | 1" | 1 5/16" | 60" | 0000000 | 00000000 | 0000000 |
Precise-Flow Electric Drum Pumps for Water, Oil, and Chemicals
For accurate dispensing in extremely low-flow applications, adjust flow in 2% increments. These pumps are compatible with chemicals such as ammonia and etching and cleaning solutions.
Temp. Range, °F | Intake | Discharge | Pumps | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Includes | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Each | |
120V AC, Single Phase | ||||||||||||||||
Plug | ||||||||||||||||
0.001-0.01 | 100 | 30 | 1,500 | 35° | 125° | 1/30 hp | 1.7 | 2" | Tube Nut Connector | 3/8" | 20ft. | 1/4" | 1/4" | 20ft. | 0000000 | 0000000 |
0.001-0.1 | 100 | 30 | 1,500 | 35° | 100° | 1/16 hp | 0.6 | 2" | Drum Connector | 3/8" | 20ft. | 1/4" | 1/4" | 20ft. | 0000000 | 00000000 |
Electric Drum Pump Systems for Water, Oil, Coolants, and Chemicals
Including nozzles and connectors, these pumps come with everything you need to start pumping. All include a pump assembly, 1" ID hose, dispensing nozzle, drum connector, and storage bracket.
Pumps with an aluminum housing are often used with lubricating oil and coolants. Their motors are rated IP44.
Pumps with a polypropylene housing are often used with corrosives such as acid-washing solutions and cleaning and etching fluids. Their motors are rated IP44.
Pumps with a PVDF housing are often used with aggressive chemicals such as 98% nitric acid, hydrochloric acid, and sulfuric acid. Their motors are rated IP54.
Pumps with a 316 stainless steel housing are often used with fuel, acetone, methyl ethyl ketone (MEK), xylene, and mineral spirits. Their motors are rated IP55 and are CSA certified for use in Class I, Divisions 1 and 2, Group D hazardous environments with flammable gases and vapors.
Pumps with a 47" intake tube can be used with large totes and tanks.
For technical drawings and 3-D models, click on a part number.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size | Tube OD | Tube Lg. | Tube ID | Tube OD | Tube Lg. | Environmental Rating | Each | |
120V AC, Single Phase—NEMA 5-15 Plug | ||||||||||||||||
Aluminum Housing | ||||||||||||||||
22 | 15 | 55 | 1,500 | Not Rated | 175° | 1 hp | 7.5 | 2 NPT | 1 1/2" | 39" | 1" | 1 1/4" | 72" | IP44 | 0000000 | 000000000 |
22 | 15 | 55 | 1,500 | Not Rated | 175° | 1 hp | 7.5 | 2 NPT | 1 1/2" | 47" | 1" | 1 1/4" | 72" | IP44 | 0000000 | 00000000 |
Polypropylene Plastic Housing | ||||||||||||||||
15 | 15 | 55 | 1,500 | Not Rated | 130° | 1 hp | 7.5 | 2 NPT | 1 5/8" | 39" | 1" | 1 1/4" | 72" | IP44 | 0000000 | 00000000 |
15 | 15 | 55 | 1,500 | Not Rated | 130° | 1 hp | 7.5 | 2 NPT | 1 5/8" | 47" | 1" | 1 1/4" | 72" | IP44 | 0000000 | 00000000 |
PVDF Plastic Housing | ||||||||||||||||
15 | 15 | 55 | 1,500 | Not Rated | 175° | 1 hp | 7.5 | 2 NPT | 1 5/8" | 39" | 1" | 1 1/4" | 72" | IP54 | 0000000 | 00000000 |
15 | 15 | 55 | 1,500 | Not Rated | 175° | 1 hp | 7.5 | 2 NPT | 1 5/8" | 47" | 1" | 1 1/4" | 72" | IP54 | 0000000 | 00000000 |
120V AC, Single Phase—Hardwire | ||||||||||||||||
316 Stainless Steel Housing | ||||||||||||||||
18 | 15 | 55 | 1,000 | Not Rated | 175° | 1 1/3 hp | 9.1 | 2 NPT | 1 1/2" | 39" | 1" | 1 1/4" | 72" | NEC Class I Divisions 1, 2 Group D IP55 | 0000000 | 00000000 |
Sanitary Electric Drum Pumps
Commonly used in food, beverage, pharmaceutical, and cosmetic processing, these pumps are designed for sanitary environments. The discharge connection can be easily disassembled for cleaning. Pumps do not include a drum connector.
Pumps with a 47" intake tube can be used with large totes and tanks.
Pumps with a maximum viscosity of 100,000 cP handle a wide range of liquid thicknesses from water up to lotions and pie fillings.
Pumps that are 3-A certified meet sanitary design standards. Those that are CSA certified meet stringent safety standards.
Temp. Range, °F | Intake | Discharge | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | For Drum Opening Size, mm | Tube OD | Tube Lg. | Tube Connection Type | For Tube OD | Thermal Protection | Specifications Met | Each | |
115V AC, Single Phase—Hardwire | ||||||||||||||||
Nylon Plastic Housing | ||||||||||||||||
31 | 10 | 55 | 1,000 | 15° | 175° | 1 hp | 4.2 | 38 | 1 1/2" | 39" | Quick Clamp | 1 1/2" | With Thermal Overload Protection | 3-A Certified 02-11; CSA Certified | 0000000 | 000000000 |
120V AC, Single Phase—Plug | ||||||||||||||||
Polypropylene Plastic Housing | ||||||||||||||||
57 | 14 | 55 | 600 | 35° | 210° | 7/10 hp | 4 | 43 | 1 11/16" | 39" | Quick Clamp | 1 1/2" | With Thermal Overload Protection | 3-A Certified 02-11 | 0000000 | 00000000 |
57 | 14 | 55 | 600 | 35° | 210° | 7/10 hp | 4 | 43 | 1 11/16" | 47" | Quick Clamp | 1 1/2" | With Thermal Overload Protection | 3-A Certified 02-11 | 0000000 | 00000000 |
58 | 17 | 55 | 800 | 35° | 210° | 1.07 hp | 7.5 | 43 | 1 11/16" | 39" | Quick Clamp | 1 1/2" | With Thermal Overload Protection | 3-A Certified 02-11 | 0000000 | 00000000 |
58 | 17 | 55 | 800 | 35° | 210° | 1.07 hp | 7.5 | 43 | 1 11/16" | 47" | Quick Clamp | 1 1/2" | With Thermal Overload Protection | 3-A Certified 02-11 | 0000000 | 00000000 |
190V AC, 380V AC, 230V AC, 460V AC; Three Phase—Hardwire | ||||||||||||||||
Aluminum Housing | ||||||||||||||||
7 | 87 | 55 | 100,000 | 15° | 300° | 1 1/2 hp | 6.4, 3.2, 5.8, 2.9 | 50 | 2" | 39" | Quick Clamp | 1 1/2" | Without Thermal Overload Protection | __ | 0000000 | 000000000 |
Electric Drum Pumps with Nozzle for Fuel
Pump fuel in hazardous environments with flammable gases. Pumps are UL listed for Class I, Divisions 1 and 2, Group D.
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Style A pumps have a circuit breaker to prevent overload. Pumps with automatic shut-off nozzle turn off when the tank is full.
Style B pumps have a metering nozzle that registers total volume up to 99,999.9 gallons. Lock with a padlock (not included). A bypass valve prevents pressure buildup when the nozzle is closed.
Anti-siphon kit prevents reverse flow with a vacuum breaker and includes all hose, fittings, and seals required for installation. Pedestal kit converts your pump from a drum mount to a pedestal mount.
Temp. Range, °F | Intake | Discharge | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Tube OD | Tube Lg. | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 4.8 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Automatic Shut-Off | Hardwire | 0000000 | 0000000 |
12 | 15 | 10 | -20° | 125 | 1/8 hp | 1.5 | 5.5 | 2 NPT | 1 7/16" | 22"-40" | 3/4" | 12 | 1 5/32" | Manual Shut-Off | Hardwire | 0000000 | 000000 |
Temp. Range, °F | Intake | Discharge | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max.Lift, ft. | For Drum Opening Size | Gender | Pipe Size | Thread Type | Hose ID | Hose Lg., ft. | Hose OD | Nozzle Type | Max. Shackle Dia. | Electrical Connection Type | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
20 | 22 | 10 | -40° | 150 | 1/3 hp | 5.5 | 10 | 2 NPT | Female | 1 1/4 | NPT | 3/4" | 12 | 1 1/8" | Lockable, Manual Shut-Off, Metering | 3/8" | Hardwire | 0000000 | 000000000 |
Battery-Operated Siphon Drum Pumps
Quickly generate suction with battery power.
Temp. Range, °F | Intake | Discharge | Batteries | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Drum Pump Type | Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | Min. | Max. | For Drum Opening Size | Tube OD | Tube Lg. | Location | Tube ID | Tube OD | Tube Lg. | Included | Size | No. of Required | Each | |
For Use With Kerosene | |||||||||||||||||
Siphon | 1.8 | 5 | 3 | Not Rated | 140° | 1 13/16" | 15/16" | 12 1/2" | Tube End | 1/2" | 9/16" | 24" | No | D | 2 | 0000000 | 000000 |
For Use With Water | |||||||||||||||||
Siphon | 1.5 | 5 | 3 | Not Rated | 120° | 55 mm | 1 1/8" | 16" | Spout End | __ | __ | __ | No | D | 2 | 0000000 | 00000 |
Portable Battery-Operated Drum Pumps for Diesel Fuel
For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
Temp. Range, °F | Intake | Discharge | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | Includes | Hose Connection Type | For Hose ID | Hose Connection Type | For Hose ID | Features | Each | |
12V DC, Single Phase | |||||||||||||||
13 | 21 | 5.3 | 25° | 100° | Not Rated | 18 | 6 | 6 1/2-ft. Battery Cable with Clamps | Barbed | 3/4" | Barbed | 3/4" | Bypass Relief Valve | 00000000 | 0000000 |
Portable Battery-Operated Drum Pumps with Nozzle for Diesel Fuel
A nozzle and hose allow you to dispense directly into your container. For on-site diesel fuel dispensing at construction sites, on boats, and in other environments without electrical hookups, attach these portable pumps to any 12-volt battery.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | Includes | Hose Connection Type | For Hose ID | ID | Lg., ft. | Features | Each | |
12V DC, Single Phase | |||||||||||||||
13 | 14 | 5.3 | 25° | 100° | Not Rated | 22 | 6 | 6 1/2-ft. Battery Cable with Clamps | Barbed | 3/4" | 3/4" | 13 | Bypass Relief Valve | 00000000 | 0000000 |
Battery-Operated Drum Pumps with Nozzle for Fuel
Operating on a 12-volt battery, these pumps transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with metering nozzle record total volume up to 99,999.9 gallons.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Tube OD | Tube Lg. | ID | Lg., ft. | Nozzle Type | Each | |
12V DC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Manual Shut-Off, Lockable | 0000000 | 0000000 |
15 | 12 | 30 | -15° | 150° | 1/4 hp | 20 | 8 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1" | 20"-34 3/4" | 3/4" | 12 | Metering, Manual Shut-Off | 0000000 | 000000 |
Hazardous Location High-Flow Battery-Operated Drum Pumps with Nozzle for Fuel
These pumps are C-UL listed for Class I, Division 2, Group D for use in environments with flammable gases. Operating on a 12-volt battery, use them to transfer and drain fuel such as gasoline, diesel fuel, and kerosene. Lock the nozzle with a padlock (not included).
Always bond and ground your application for static control. For more information about bonding and grounding, see Sections 1910.106 and 1910.107 of the Federal OSHA Code or see bonding and grounding equipment.
Pumps with automatic shut-off nozzle turn off when the tank is full.
Temp. Range, °F | Intake | Discharge (Hose and Nozzle) | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Discharge Pressure, psi | Max. Viscosity, cP | Min. | Max. | Horsepower | Current, A | Max. Lift, ft. | For Drum Opening Size | Includes | Pipe Size | Gender | Thread Type | ID | Lg., ft. | Nozzle Type | Max. Shackle Dia. | Thermal Protection | Each | |
12V DC | |||||||||||||||||||
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Automatic Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000000 |
25 | 20 | 10 | -20° | 125° | 4/10 hp | 35 | 15 | 2 NPT | 18-ft. Battery Cable, Drum Connector | 1 | Female | NPT | 1" | 18 | Manual Shut-Off, Lockable | 5/16" | With Thermal Overload Protection | 0000000 | 000000 |
Battery-Operated Drum Pumps with Nozzle for Oil
Quickly and cleanly transfer oil with no need for an electrical connection, air connection, or manual pumping. These drum pumps come with everything they need to operate.
Add extra stem assemblies to move a single pump head across multiple containers.
Use additional pump heads to transfer oil to multiple locations at once. Pump heads fit all stem assemblies.
To control the exact amount of oil you move, connect a meter.
Add batteries to minimize downtime—swap in a second battery while another charges.
Intake Tube | Discharge (Hose and Nozzle) | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | For Container Size, gal. | Max. Viscosity, cP | For Use With | Temp. Range, °F | Horsepower | For Drum Opening Size | Includes | OD | Lg. | Hose ID | Hose Lg., ft. | Nozzle Type | Batteries Included | Features | Each | |
Single Phase—With Thermal Overload Protection | ||||||||||||||||
1.5 | 5 | 2,200 | Automatic Transmission Fluid, Coolant, Gear Oil, Hydraulic Oil, Motor Oil | 32° to 100° | 1/15 hp | 2 NPT | Drum Connector | 1" | 12 3/4"-17 1/2" | 3/4" | 5 | Manual Shut-Off | Yes | Removable Pump Head | 00000000 | 0000000 |
1.5 | 16 - 55 | 2,200 | Automatic Transmission Fluid, Coolant, Gear Oil, Hydraulic Oil, Motor Oil | 32° to 100° | 1/15 hp | 2 NPT | Drum Connector | 1" | 21 1/2"-39 3/4" | 3/4" | 5 | Manual Shut-Off | Yes | Removable Pump Head | 00000000 | 000000 |
Intake Tube | ||||||||
---|---|---|---|---|---|---|---|---|
For Container Size, gal. | For Drum Opening Size | Includes | OD | Lg. | Hose Lg., ft. | Nozzle Type | Each | |
For Automatic Transmission Fluid, Coolant, Gear Oil, Hydraulic Oil, Motor Oil | ||||||||
5 | 2 NPT | Drum Connector, Hose, Intake Tube, Nozzle | 1" | 12 3/4"-17 1/2" | 5 | Manual Shut-Off | 00000000 | 0000000 |
16 - 55 | 2 NPT | Drum Connector, Hose, Intake Tube, Nozzle | 1" | 21 1/2"-39 3/4" | 5 | Manual Shut-Off | 00000000 | 000000 |
Horsepower | No. of Batteries Required | Each | |
Single Phase—With Thermal Overload Protection | |||
---|---|---|---|
1/15 hp | 1 | 00000000 | 0000000 |
Scale | Accuracy | Temp. Range, °F | Pipe Size | Thread Type | Features | Each | |
Gallons, Liters, Quarts | ±2% | 0° to 155° | 1/2 | BSPP | Nonresettable Flow Counter for Total Volume; Resettable Batch Function | 00000000 | 0000000 |
Voltage | Battery Capacity, amp-hrs. | Each | |
18V DC | 2 | 00000000 | 000000 |
Battery Charging Time, hrs. | Battery Charger Voltage | Each | |
1 | 120V AC | 00000000 | 000000 |
Harsh-Environment Self-Priming Water-Removal Pumps
This pump has a totally enclosed nonventilated (TENV) motor that is cooled by the liquid being pumped. Also known as a flexible impeller pump, it creates a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. Mount up to 6 feet above your liquid source. Pump can pass solids up to 1/4" in diameter without clogging, so there’s no need to filter sediment and debris. A handle makes it convenient for on-the-go removal of bilge water, waste oil, and spills. Pump can also be used to cool marine engines and drain liquid from holding tanks.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Intake Size | Discharge Size | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||
Plug with 8 ft. Cord | |||||||||||||
5 4/5 | 30 | 1/4" | 125 | 60° to 180° | 1/4 hp | 4.2 | 1/2 NPT Female, 3/4 GHT Male | 1/2 NPT Female, 3/4 GHT Male | 9" | 5 5/8" | 7 3/8" | 0000000 | 0000000 |
Water Removal Pumps with Hose
Use this pump to remove water with small solids up to 1/4" in diameter. It activates when plugged in; add a plug-in switch to control when the pump activates. Install in water that's at least 2" deep. Pump includes a 25-ft. hose with cam-and-groove fittings for quick, secure connections and a storage crate with built-in filtration to protect the pump from debris.
Note: Pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Connection Coupling Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||
Plug with 15" Cord | |||||||||||||||||
41 | 32 | 23 | 11 | 41 gpm | 25 | 1/4" | 7/16" | 35° to 100° | 4/10 hp | 3 | 1 1/4 | Male | 12 3/4" | 11 13/16" | 15 3/4" | 0000000 | 0000000 |
Battery-Operated Water-Removal Pumps
Remove water in locations without power with these battery-operated pumps. Do not run dry.
Continuous duty pumps attach to a 12-volt battery. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
Intermittent duty pumps attach to an 18-volt battery. They have a motor that can handle up to one hour on, 10 minutes off. They must be filled with liquid before they can draw liquid up from a source below.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 4 Ft. of Head | @ 5 Ft. of Head | @ 8 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Flow Rate | Max. Ft. of Head, ft. | Temp. Range, °F | Current, A | For Tube OD | Gender | Ht. | Wd. | Lg. | Each | |
45 | 42 | 28 | 25 | 13 | 65 gpm | 22 | 30° to 120° | 20 | 2" | Female | 10 1/2" | 5 1/2" | 7" | 0000000 | 0000000 |
Intake | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Temp. Range, °F | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
8 | 75 | 35° to 140° | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5 3/4" | 13 1/4" | 0000000 | 0000000 |
Heavy Duty Battery-Operated Water-Removal Pumps
This pump has an impact-resistant aluminum housing and handles larger solids than other battery-operated water-removal pumps. Attach it to a 12-volt battery to remove water in locations without power. Pump is gravity fed and requires an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Discharge | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate @ 5 Ft. of Head, gpm | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Ht. | Each | |
12V DC—With Thermal Overload Protection | |||||||||||||
41 | 20 | 1/4" | 1/4" | 35° to 190° | 1/3 hp | 30 | 1 1/2 | NPT | Female | 9 37/64" | 22 3/64" | 000000 | 000000000 |
Compact Water-Removal Pumps
Also known as bilge pumps, these remove fresh and salt water from spots where other pumps don’t fit. They have an internal sensor, so they turn on when they detect water and turn off when the water is removed. Pumps are fully submersible. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on.
Pumps for 12 volts DC work with 12-volt batteries.
Pumps for 120 volts AC are for use in debris-free water.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current, A | For Tube ID | Gender | Dia. | Ht. | Each | |
ABS Plastic Housing | |||||||||||||
Hardwire with 2 ft. Cord | |||||||||||||
5 | 1 | 11 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 1.6 | 3/4" | Male | 3" | 4" | 0000000 | 000000 |
10 | 3 | 10 | 1/4" | 30° to 140° | 2.5 min. | Not Rated | 3.7 | 1", 1 1/8" | Male | 3" | 5" | 0000000 | 000000 |
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Sensor Time Interval | Horsepower | Current | Pipe Size | Thread Type | Gender | Dia. | Ht. | Includes | Each | |
ABS Plastic Housing | |||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 24 ft. Cord | |||||||||||||||
20 | 13 | 18 | 1" | 40° to 140° | 2.5 min. | Not Rated | Not Rated | 1 | NPT | Male | 5" | 8" | Garden Hose Adapter | 0000000 | 000000 |
Plastic Water-Removal Pumps
Clean up water in flooded areas without a sump pit. Install these pumps in debris-free water that’s at least 2" deep. They activate when plugged in. You can add a plug-in switch to control when the pump activates. Submerge while in use.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Includes | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 6 | 1 1/4 | NPT | Female | 10" | 8" | 8" | Garden Hose Adapter | 0000000 | 0000000 |
29 | 27 | 21 | 12 | 28 | 5/8" | 35° to 120° | 1/3 hp | 10 | 1 1/4 | NPT | Female | 11" | 8" | 8" | Garden Hose Adapter | 00000000 | 000000 |
Impact-Resistant Metal Water-Removal Pumps
An aluminum housing provides excellent impact resistance. Use these pumps to clean up water in flooded areas without a sump pit. Install them in debris-free water that’s at least 2” deep. Pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Submerge while in use.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Discharge | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Includes | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 8 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 5.6 | 1 1/4 | NPT | Female | 9" | 7" | 7" | Garden Hose Adapter | 0000000 | 0000000 |
Plug with 25 ft. Cord | |||||||||||||||||
19 | 17 | 13 | 8 | 25 | 1/8" | 35° to 120° | 1/4 hp | 5.6 | 1 1/4 | NPT | Female | 9" | 7" | 7" | Garden Hose Adapter | 0000000 | 000000 |
Miniature Water-Removal Pumps with Hose
Complete with a suction strainer and 6 feet of garden hose, this little pump comes ready to clean up small open spaces. It activates when you plug it in. Use with debris-free water.
Maintenance kits (sold separately) include an impeller, an O-ring, and a seal.
Note: The pump must be filled with liquid before use. It needs a constant flow of liquid and cannot run dry.
Max. Flow Rate, gpm | Intake | Discharge | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Thread Size | Thread Type | Gender | Hose Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 6 ft. Cord | |||||||||||||||||||
5.5 | 5 | 4.5 | 4 | 43 | 1/8" | 35° to 75° | 1/12 hp | 2 | 3/4 | GHT | Male | 3/4 | GHT | Male | 6" | 5" | 7" | 0000000 | 0000000 |
Maintenance Kit | 0000000 | Each | 000000 |
Easy-Carry Water-Removal Pumps without Switch
These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
115V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||
23 | 20 | 14 | 9 | 26 | 1/8" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 6" | 4.3" | 00000000 | 0000000 |
Plug with 25 ft. Cord | ||||||||||||||||
18 | 17 | 14 | 9 | 26.3 | 1/8" | 35° to 120° | 1/6 hp | 5 | 1 | NPT | Female | 8" | 7" | 5" | 00000000 | 000000 |
Long-Life Easy-Carry Water-Removal Pumps
The switch activates on increasing pressure caused by rising water levels for a long service life. It has a separate cord, so you can replace the switch without replacing the whole pump. Use the handle to carry pumps from job to job. Install in debris-free water that’s at least 3/4" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Removes Water Down To | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||
23 | 19 | 8 | 26 | 1/8" | 9" | 4" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 0000000 |
Plug with 18 ft. Cord | |||||||||||||||||
23 | 19 | 8 | 26 | 1/8" | 3" | 1 1/2" | 35° to 120° | 1/6 hp | 2 | 1 | NPT | Female | 8" | 8" | 5" | 00000000 | 000000 |
High-Flow Water-Removal Pumps
Pumps have a powerful motor that provides more than twice the flow rate of standard water-removal pumps to quickly remove large volumes of liquid. They activate when plugged in; add a float switch to control when the pump activates. A top-discharge design routes water through the pump to cool the motor. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before during on. Do not run dry.
Install 1/3 horsepower pumps in water that’s at least 2” deep.
Install 1/2 horsepower pumps in water that’s at least 4” deep.
Pumps | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Discharge | Overall | Replacement Cords | ||||||||||||||||
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | Each | ||
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 10 ft. Cord | |||||||||||||||||||
73 | 64 | 44 | 16 | 34 | 3/8" | 2" | 35° to 120° | 1/2 hp | 8 | 1 1/2 | NPT | Female | 13" | 9" | 9" | 00000000 | 0000000 | 00000000 | 0000000 |
Plug with 25 ft. Cord | |||||||||||||||||||
48 | 43 | 23 | __ | 26 | 3/8" | 2" | 35° to 120° | 1/3 hp | 4.9 | 1 1/4 | NPT | Female | 9" | 6" | 6" | 00000000 | 000000 | 00000000 | 000000 |
73 | 64 | 44 | 16 | 34 | 3/8" | 2" | 35° to 120° | 1/2 hp | 8 | 1 1/2 | NPT | Female | 13" | 9" | 9" | 00000000 | 000000 | 00000000 | 000000 |
Ultra High-Flow Water-Removal Pumps without Switch
NEMA 5-15 | |
NEMA 6-15 |
Move higher volumes of water than with other high-flow water-removal pumps. These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. A top-discharge design routes water through the pump to cool the motor. Install in water that’s at least 10" deep. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Max. Flow Rate, gpm | Discharge | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Temp. Range | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
5-15 NEMA Plug with 30 ft. Cord | ||||||||||||||||
70 | 50 | 24 | 36 | 3/8" | 4" | 35° to 120° | 1/2 hp | 10.3 | 1 1/2 | NPT | Female | 15" | 7" | 7" | 0000000 | 000000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||
6-15 NEMA Plug with 30 ft. Cord | ||||||||||||||||
__ | 82 | 61 | 52 | 3/8" | 4" | 35° to 120° | 1 hp | 6.3 | 1 1/2 | NPT | Female | 16" | 7" | 7" | 0000000 | 00000000 |
Portable Sewage Water-Removal Pumps
Transfer raw sewage water that contains solids up to 2” in diameter. These pumps have a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. The length of the float switch cord is adjustable. Turn-on and turn-off levels will vary according to the length of the cord. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry.
Pumps with male discharge port have a horizontal discharge.
Pumps with female discharge port have a vertical discharge.
Max. Flow Rate, gpm | Level | Discharge (NPT) | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Removes Water Down To | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Dia. | Dp. | Dia. | Ht. | Wd. | Each | |
240V AC, Single Phase | |||||||||||||||||||
Hardwire with 25 ft. Cord | |||||||||||||||||||
__ | 80 | 44 | 35 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 hp | 6.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 000000000 |
__ | 114 | 79 | 46 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 100° | 1 1/2 hp | 8.4 | 2 | Male | 22" | 24" | __ | 19" | 10" | 0000000 | 00000000 |
100 | 78 | 41 | 33 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 hp | 6.3 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |
134 | 114 | 77 | 41 | 2" | 5 1/2" | 20"-22" | 4"-12" | 35° to 130° | 1 1/2 hp | 8.4 | 2 | Female | 22" | 24" | 10" | 18" | __ | 0000000 | 00000000 |