About Sump, Water-Removal, Condensate, and Submersible Pumps
More
Sump Pumps without Float Switch for Water with Small Solids
These pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Also known as effluent pumps, these accommodate solids up to 3/4" in diameter. They’re often used with liquid waste that has passed through a septic tank, so most solids are removed. They have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | @ 40 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
53 | 50 | 42 | 34 | __ | __ | 28 | 1/2" | 35° to 140° | 1/3 hp | 5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 9" | 00000000 | 0000000 |
60 | 55 | __ | 45 | 30 | 15 | 60 | 3/4" | 35° to 140° | 1/2 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 8" | 00000000 | 000000 |
Float-Switch Activated Sump Pumps for Water with Small Solids
Also known as effluent pumps, these accommodate solids up to 3/4” in diameter. They’re often used with liquid waste that has passed through a septic tank, so most solids are removed. The float switch is wired to the pump. All have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | @ 40 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||||
53 | 50 | 42 | 34 | __ | __ | 28 | 1/2" | 11" | 5" | 35° to 140° | 1/3 hp | 5 | 1 1/2 | NPT | Female | 18" | 24" | 12" | 11" | 9" | 00000000 | 0000000 |
Plug with 20 ft. Cord | ||||||||||||||||||||||
60 | 55 | __ | 45 | 30 | 15 | 60 | 3/4" | 11" | 6" | 35° to 140° | 1/2 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 11" | 8" | 00000000 | 000000 |
Sump Pumps for Water with Small Solids with Replaceable Float Switch
The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as effluent pumps, these accommodate solids up to 3/4" in diameter. They’re often used with liquid waste that has passed through a septic tank, so most solids are removed. All have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | @ 40 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||||
53 | 50 | 42 | 34 | __ | __ | 28 | 1/2" | 15" | 8" | 35° to 140° | 1/3 hp | 5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 9" | 00000000 | 0000000 |
Plug with 20 ft. Cord | ||||||||||||||||||||||
60 | 55 | __ | 45 | 30 | 15 | 60 | 3/4" | 16" | 10" | 35° to 140° | 1/2 hp | 9 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 8" | 00000000 | 000000 |
70 | 65 | __ | 50 | 26 | __ | 40 | 3/4" | 12" | 6" | 35° to 140° | 2/5 hp | 7.5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 8" | 00000000 | 000000 |
High-Temperature Float-Switch Activated
Sump Pumps for Water with Small Solids
Use these pumps at temperatures up to 200° F. Also known as effluent pumps, they accommodate solids up to 3/4" in diameter. They’re often used with liquid waste that has passed through a septic tank, so most solids are removed. The float switch is adjustable and wired to the discharge pipe. Pumps have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Replacement float switches (sold separately) include a float, connecting wires, and a seal.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Max. Temp., °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||
90 | 75 | 53 | 30 | 26 | 5/8" | 200° | 1/2 hp | 10.7 | 1 1/2 | NPT | Female | 18" | 30" | 13" | 12 1/4" | 9 5/8" | 00000000 | 000000000 |
Replacement Float Switch for Pump with 1/2 Horsepower | 00000000 | Each | 000000 |
High-Flow Sump Pumps without Switch for Water with Small Solids
Use these pumps to move higher volumes of water with solids than other sump pumps. They activate when plugged in; add a plug-in switch to control when the pump activates. Also known as effluent pumps, they accommodate solids up to 3/4" in diameter. They are often used with liquid waste that has passed through a septic tank, so most solids are removed. Pumps have an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Pumps with wire leads can be connected to a three-pronged plug or wired directly to a power source.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | @ 40 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
__ | __ | 60 | 40 | 20 | __ | 50 | 3/4" | 35° to 140° | 1/2 hp | 12.5 | 2 | NPT | Female | 18" | 24" | 17" | 15" | 10" | 00000000 | 000000000 |
70 | 65 | 50 | 26 | __ | __ | 40 | 3/4" | 35° to 140° | 2/5 hp | 7.5 | 1 1/2 | NPT | Female | 18" | 24" | 11" | 9" | 8" | 00000000 | 000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire with 20 ft. Cord and Wire Leads | ||||||||||||||||||||
__ | __ | __ | 90 | 70 | 52 | 81 | 3/4" | 35° to 140° | 1 hp | 10.2 | 2 | NPT | Female | 24" | 30" | 17" | 15" | 10" | 00000000 | 00000000 |
Plug with 20 ft. Cord | ||||||||||||||||||||
__ | __ | 135 | 125 | 110 | 98 | 110 | 3/4" | 35° to 140° | 2 hp | 16.4 | 2 | NPT | Female | 30" | 30" | 18" | 13" | 9" | 00000000 | 00000000 |
High-Flow Sump Pumps for Water with
Small Solids with Replaceable Float Switch
Use this pump to move higher volumes of water with solids than other sump pumps. It has a screenless, nonclogging design to handle solids up to 3/4" in diameter. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as an effluent pump, it is often used with liquid waste that has passed through a septic tank, so most solids are removed. Pump has an epoxy-coated cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn-On | Turn-Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 93 | 85 | 79 | 50 | 3/4" | 15" | 5" | 35° to 130° | 1/2 hp | 15.5 | 1 1/2 | NPT | Female | 24" | 30" | 20" | 13" | 11" | 0000000 | 000000000 |
Sump Pumps with Basin for Water with Small Solids
Convenient for applications where a sump pit is impractical, this pump includes a basin with a vent on top. It has a float switch with a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as an effluent pump, it accommodates solids up to 3/4" in diameter. It is often used with liquid waste that has passed through a septic tank, so most solids are removed.
Max. Flow Rate | Level | Intake (NPT) | Discharge (NPT) | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Capacity, gal. | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Gender | Pipe Size | Gender | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 10 ft. Cord | ||||||||||||||||||||
70 | 65 | 50 | 26 | 40 | 3/4" | 10" | 5" | 5 | 35° to 125° | 2/5 hp | 7.5 | 1 1/2 | Female | 1 1/2 | Female | 16" | 15" | 15" | 0000000 | 0000000 |
Sump Pumps without Float Switch for Sewage Water
Pumps activate when plugged in. You can add a plug-in switch to control when the pump activates. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 000000 |
208/230V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||
120 | 100 | 80 | 25 | 2" | 35° to 140° | 1/2 hp | 5.5 | Open | 2 | NPT | Female | 18" | 24" | 14" | 8.6" | 10.4" | 00000000 | 000000 |
Sump Pumps for Sewage Water with Replaceable Float Switch
The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Equipped with a large intake and rugged impeller, these pumps transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 19" | 11" | 35° to 140° | 2/5 hp | 8 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 19" | 11" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 14" | 10" | 9" | 00000000 | 000000 |
Float-Switch Activated Sump Pumps for Sewage Water
Equipped with a large intake and a rugged impeller, this pump transfers raw sewage water with solids up to 2" in diameter. It has a cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 20 ft. Cord | ||||||||||||||||||||
100 | 80 | 60 | 20 | 2" | 13" | 8" | 35° to 140° | 4/10 hp | 8 | Open | 2 | NPT | Female | 18" | 30" | 14 1/2" | 11" | 9" | 00000000 | 0000000 |
120 | 100 | 80 | 25 | 2" | 14" | 9" | 35° to 140° | 1/2 hp | 11 | Open | 2 | NPT | Female | 18" | 24" | 15" | 11" | 9" | 00000000 | 000000 |
Clog-Resistant Sump Pumps for Sewage Water with Replaceable Float Switch
The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Also known as grinder pumps, they have stainless steel blades that prevent clogs by breaking down sewage into an easy-to-transfer slurry. Do not use with metal particles or debris that could damage blades. Pumps have a cast iron housing that stands up to demanding environments. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 15 Ft. of Head | @ 20 Ft. of Head | @ 30 Ft. of Head | @ 40 Ft. of Head | @ 50 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Dia. | Ht. | Each | |
Plug with 20 ft. Cord | |||||||||||||||||||||
42 | 39 | 37 | 31 | 20 | 6 | 55 | 3" | 20" | 12" | 35° to 100° | 1 hp | 13 | 1 1/4 | NPT | Female | 18" | 30" | 12" | 20" | 0000000 | 000000000 |
42 | 39 | 37 | 31 | 20 | 6 | 55 | 3" | 20" | 12" | 35° to 100° | 1 hp | 13 | 2 | NPT | Female | 18" | 30" | 12" | 20" | 0000000 | 00000000 |
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 60 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
Plug with 20 ft. Cord | |||||||||||||||||||
32 | 30 | 20 | 130 | 2" | 24" | 10" | 35° to 140° | 2 hp | 13.9 | 1 1/4 | NPT | Female | 24" | 48" | 22" | 12" | 10" | 0000000 | 000000000 |
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | O'all | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 10 Ft. of Head | @ 60 Ft. of Head | @ 70 Ft. of Head | @ 80 Ft. of Head | @ 90 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Dia. | Dp. | Dia. | Ht. | Each | |
Plug with 20 ft. Cord | |||||||||||||||||||||
44 | 43 | 40 | 35 | 20 | 5 | 133 | 3" | 22" | 14" | 35° to 100° | 2 hp | 15 | 2 | NPT | Female | 18" | 30" | 12" | 22" | 0000000 | 000000000 |
Float-Switch Activated Clog-Resistant Sump Pumps for Sewage Water
Also known as a grinder pump, this pump has stainless steel blades that prevent clogs by breaking down sewage into an easy-to-transfer slurry. Do not use with metal particles or debris that could damage blades. Pump has an epoxy-coated cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Submerge while in use and do not run dry.
Max. Flow Rate, gpm | Level | Intake | Discharge | Min. Sump Pit | O'all | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 20 Ft. of Head | @ 60 Ft. of Head | @ 100 Ft. of Head | Max. Ft. of Head, ft. | Turn On | Turn Off | Temp. Range Max., °F | Horsepower | Current, A | Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||
Plug with 20 ft. Cord | |||||||||||||||||||||
46 | 43 | 7 | 107 | 24" | 6" | 130° | 2 hp | 13.7 | 1 1/4 | NPT | Female | 1 1/4 | NPT | Female | 24" | 48" | 19" | 12" | 8" | 0000000 | 000000000 |
High-Flow Sump Pumps without Float Switch for Sewage Water
These pumps provide over 50% more flow than standard plug-in activated pumps for sewage water. They activate when plugged in. You can add a plug-in switch to control when the pump activates. Pumps are equipped with a large intake and rugged impeller to transfer raw sewage water with solids up to 2" in diameter. All have a cast iron housing that stands up to demanding environments. Pumps can run dry.
Pumps with wire leads can be connected to a three-pronged plug or wired directly to a power source.
Max. Flow Rate, gpm | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Wire Connection Type | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Plug with 15 ft. Cord | |||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 35° to 100° | 1/2 hp | 11.6 | Open | 2 | NPT | Female | __ | 24" | 30" | 19" | 10" | 13" | 0000000 | 000000000 |
200/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire with 30 ft. Cord | |||||||||||||||||||
220 | 190 | 160 | 36 | 2" | 35° to 100° | 1 hp | 8.8A/8.3A | Open | 3 | NPT | Female | Wire Leads | 24" | 30" | 19" | 10" | 14" | 0000000 | 00000000 |
240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||
Hardwire with 20 ft. Cord | |||||||||||||||||||
410 | 370 | 312 | 46 | 2" | 35° to 100° | 2 hp | 19 | Open | 3 | NPT | Female | Wire Leads | 24" | 30" | 22" | 13" | 17" | 0000000 | 00000000 |
High-Flow Float-Switch Activated Sump Pumps for Sewage Water
These pumps provide about 25% more flow than standard float-switch activated pumps for sewage water. Equipped with a large intake and rugged impeller, they transfer raw sewage water with solids up to 2" in diameter. All have a cast iron housing that stands up to demanding environments. The float switch is wired to the pump. Pumps can run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 20" | 13" | 35° to 100° | 1/2 hp | 11.6 | Open | 2 | NPT | Female | 24" | 30" | 19" | 10" | 13" | 0000000 | 000000000 |
240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 20" | 13" | 35° to 100° | 1/2 hp | 5.9 | Open | 2 | NPT | Female | 24" | 30" | 19" | 10" | 13" | 0000000 | 00000000 |
High-Flow Sump Pumps for Sewage Water with Replaceable Float Switch
These pumps provide about 25% more flow than standard float-switch activated pumps for sewage water. The float switch has a separate cord that can unplug, so you can replace the switch without replacing the whole pump. Pumps are equipped with a large intake and rugged impeller to transfer raw sewage water with solids up to 2" in diameter. They have a cast iron housing that stands up to demanding environments. Pumps can run dry.
Max. Flow Rate, gpm | Level | Discharge | Min. Sump Pit | Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
@ 5 Ft. of Head | @ 10 Ft. of Head | @ 15 Ft. of Head | Max. Ft. of Head, ft. | Max. Solids Dia. | Turn On | Turn Off | Temp. Range, °F | Horsepower | Current, A | Intake Inlet Connection Type | Pipe Size | Thread Type | Gender | Dia. | Dp. | Ht. | Wd. | Lg. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Plug with 15 ft. Cord | ||||||||||||||||||||
120 | 96 | 65 | 26 | 2" | 13" | 6" | 35° to 75° | 2/5 hp | 12 | Open | 2 | NPT | Female | 24" | 30" | 17" | 8" | 11" | 0000000 | 0000000 |
Plug with 20 ft. Cord | ||||||||||||||||||||
160 | 130 | 100 | 25 | 2" | 13" | 6" | 35° to 100° | 1/2 hp | 11.6 | Open | 2 | NPT | Female | 24" | 30" | 19" | 10" | 13" | 0000000 | 000000 |
Pressure Switches for Sump Pumps
Since these switches activate on increasing pressure caused by rising water levels, they have no floats to catch on sump pit walls. Use them to replace an existing switch, or pair them with a plug-in activated pump to control when the pump activates.
Switch with wire leads can be connected to a three-pronged plug or wired directly to a power source.