Choosing an Electrical Switch
More
Plastic Emergency Stop Enclosed Push-Button Switches
Rated NEMA 3S, NEMA 4X, NEMA 13, and IP66, these plastic switches resist corrosion better than aluminum switches and withstand washdowns and oil/coolant spraying. Housed in a yellow enclosure for quick identification, they immediately cut power with a single push. They meet EN 418 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick.
Key reset switches are keyed alike, so if you buy multiple switches they will all reset with the same key.
Switches with a power indicator alert you from the front and sides when the switch has been actuated.
Switches with a guard prevent accidental actuation. For extra security, lock the button in the off position with a padlock (not included) to stop these switches from being reset or turned on during machine repairs.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Buttons | Actuator Color | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Conduit Trade Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw-Clamp Terminals | |||||||||||||||
Pull Reset | |||||||||||||||
1 | Red | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
1 | Red | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
Pull Reset with Guard | |||||||||||||||
1 | Red | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
1 | Red | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
Pull Reset with Power Indicator | |||||||||||||||
1 | Red | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 2 1/8" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
1 | Red | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 2 1/8" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 2 1/8" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
Key Reset (including 2 Keys) | |||||||||||||||
1 | Red | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
1 | Red | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 000000 |
Turn Reset | |||||||||||||||
1 | Red | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
1 | Red | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 600V AC 600V DC | 1 9/16" | 1/2 | No | 2 | 3/16" | 0000000 | 00000 |
No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Each | |
1 | 1 On (Normally Closed) | 2 | SPST-NC | 0000000 | 000000 |
Aluminum Emergency Stop Enclosed Push-Button Switches
These aluminum switches are rated NEMA 4, NEMA 13, and IP66 for protection from washdowns and oil/coolant spraying. Housed in a yellow enclosure for quick identification, they immediately cut power with a single push. They meet EN 60947-5-1 for compliance with European machine directives for emergency stop applications. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. UL listed and CSA certified, they also meet American and Canadian safety standards. The front of these switches is UL recognized.
Key reset switches stop you from accidentally resetting the switch before you’ve dealt with the emergency. They’re keyed alike, meaning they all open with the same key.
Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Buttons | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Dia. | Conduit Knockout Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals— 600V AC/600V DC Max. Voltage | |||||||||||||
1 | Red (SPST-NC) | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 0000000 |
1 | Red (DPST-NC) | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 000000 |
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Buttons | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Dia. | Conduit Knockout Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals— 600V AC/600V DC Max. Voltage | |||||||||||||
1 | Red (SPST-NC) | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 0000000 | 0000000 |
1 | Red (DPST-NC) | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 0000000 | 000000 |
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Buttons | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Bulb Voltage | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Dia. | Conduit Knockout Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals— 600V AC/600V DC Max. Voltage | ||||||||||||||
1 | Red (SPST-NC) | 1 | 24V AC, 24V DC | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 0000000 |
1 | Red (SPST-NC) | 1 | 120V AC | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 000000 |
1 | Red (SPST-NC) | 1 | 240V AC | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 000000 |
1 | Red (DPST-NC) | 2 | 24V AC, 24V DC | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 000000 |
1 | Red (DPST-NC) | 2 | 120V AC | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 000000 |
1 | Red (DPST-NC) | 2 | 240V AC | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 00000000 | 000000 |
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Buttons | Actuator Color (Industry Designation) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Switching Current @ Voltage | Dia. | Conduit Knockout Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals— 600V AC/600V DC Max. Voltage | |||||||||||||
1 | Red (SPST-NC) | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 0000000 | 0000000 |
1 | Red (DPST-NC) | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | 6 A @ 120 V AC, 2.5 A @ 24 V DC | 1 9/16" | PG-16 | No | 4 | 3/16" | 0000000 | 000000 |
No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Environmental Rating | Each | |
1 | 1 On (Normally Closed) | 2 | SPST-NC | IP20 | 0000000 | 000000 |
Pkg. Qty. | Pkg. | |
2 | 00000000 | 00000 |
High-Visibility Plastic Emergency Stop Enclosed Push-Button Switches
A red light flashes when the actuator is pushed, making it easy to see from a distance. These switches immediately cut power with a single push. They're housed in a protective yellow enclosure for quick identification. All have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. They're rated IP65 for protection from water projected by a nozzle.
Note: If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
Auxiliary contacts allow you to add a signaling device or control another switch.
For technical drawings and 3-D models, click on a part number.
Auxiliary Contacts | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Buttons | Actuator Color | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | Industry Designation | Switching Current @ Voltage | Max. Voltage | No. of | Switch Starting Position | Switch Position | Light Pattern | Bulb Voltage | Each | |
With 8-Pole Micro M12 Plug | ||||||||||||||
Panel Mount with Turn Reset and Emergency Stop Label | ||||||||||||||
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | DPST-NC | 2 A @ 60 V AC, 1 A @ 30 V DC | 60V AC 75V DC | 1 | 1 Off (Normally Open) | On (Normally Closed),Off (Normally Open) | Continuous Green, Flashing Red | 30V DC | 000000 | 0000000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | DPST-NC | 2 A @ 60 V AC, 1 A @ 30 V DC | 60V AC 75V DC | 1 | 1 Off (Normally Open) | On (Normally Closed),Off (Normally Open) | Continuous Yellow, Flashing Red | 30V DC | 000000 | 000000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | DPST-NC | 2 A @ 60 V AC, 1 A @ 30 V DC | 60V AC 75V DC | 1 | 1 Off (Normally Open) | On (Normally Closed),Off (Normally Open) | Flashing Red | 30V DC | 000000 | 000000 |
Surface Mount with Turn Reset and Emergency Stop Label | ||||||||||||||
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | DPST-NC | 2 A @ 60 V AC, 1 A @ 30 V DC | 60V AC 75V DC | 1 | 1 Off (Normally Open) | On (Normally Closed),Off (Normally Open) | Continuous Green, Flashing Red | 30V DC | 000000 | 000000 |
1 | Red | 2 | 2 On (Normally Closed) | Stays Switched (Maintained) | DPST-NC | 2 A @ 60 V AC, 1 A @ 30 V DC | 60V AC 75V DC | 1 | 1 Off (Normally Open) | On (Normally Closed),Off (Normally Open) | Flashing Red | 30V DC | 000000 | 000000 |
Emergency Stop Outlet-Box-Mount Push-Button Switches
Immediately cut power with a single push. The large palm-sized buttons on these switches provide an easy target, so they're easy to use even while wearing gloves. When the button is depressed, the switch latches and can be locked in that position using a lockout or padlock with a 9/32” shackle diameter (not included). All have positive force contacts that will open the circuit when actuated even if a spring fails or the contacts stick. They're rated NEMA 13 and IP65 for protection from oil/coolant spraying and washdowns.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Cover Color | Switching Current @ Voltage | Max. Voltage | Dia. | Environmental Rating | Specifications Met | Each | |
Plastic Actuator with Screw Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | Yellow | 6 A @ 120 V AC, 2.2 A @ 125 V DC | 250V DC 600V AC | 2 1/4" | NEMA 13, IP65 | UL Listed, CSA Certified, CSA-US Certified, CE Marked, UL 508, EN 60947-5-5, IEC 60947-5-5 | 00000000 | 0000000 |
Push-Button Safety Covers
Lock out the on/off or emergency-stop buttons on machinery to prevent accidental or unauthorized startups, such as during maintenance. These lockout covers secure with padlocks and indicate to workers that a button is off for safety. By disabling push buttons, these safety covers also help you comply with OSHA 29 CFR 1910.147 lockout requirements for maintaining machinery.
Removable safety covers twist on and off a mounted base that fits around a button. Use the included colored labels to identify the buttons. Red covers are easy to see when installed.
Hinged safety covers have a door that flips shut. They mount permanently and encase two button sizes—22 mm or 30 mm. Snap off the tabs around the mounting hole to fit 30 mm buttons.
Crossbar safety covers have a bar that locks a button in the off position.
Covers | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Replacement Mounting Bases | |||||||||||
For Panel Cutout Dia. | Dia. | Dp. | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Label Included | Includes | Specifications Met | Choose a Color | Each | Each | ||
Plastic | ||||||||||||
16 mm (5/8") | 2 1/2" | 1 3/4" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA Compliant 29 CFR 1910.147 | 0000000 | 000000 | 0000000 | 00000 | |
16 mm (5/8") | 2 1/2" | 3" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 | 0000000 | 0000 | |
22 mm (7/8") | 2 1/2" | 1 3/4" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 | 0000000 | 0000 | |
30 mm (1 3/16") | 1 7/8" | 2" | 1 | 5/16" | Yes | Adhesive Backing for Mounting Base | OSHA Compliant 29 CFR 1910.147 | 0000000 | 00000 | 0000000 | 0000 |
Overall | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Panel Cutout Dia. | Wd. | Ht. | Dp. | For Max. No. of Padlocks | For Max. Padlock Shackle Dia. | Specifications Met | Color | Each | |
Plastic | |||||||||
22 mm, 30 mm (7/8", 1 3/16") | 1 3/4" | 1 3/4" | 1 7/8" | 1 | 5/16" | OSHA Compliant 29 CFR 1910.147 | Clear | 0000000 | 000000 |
High-Visibility Push-Button Enclosures
Often used to house emergency-stop buttons, switches, and lights, these bright yellow enclosures are easy to spot, even in dimly lit areas. All have standard-size push-button holes to save time—no need to measure and cut your own holes.
Rated IP66 and IP68, all of these enclosures protect contents from dust, high-pressure washdowns, and submersion in water. Those with a NEMA 6P and NEMA 12 rating also guard contents from corrosion, oil, and the weather.
For technical drawings and 3-D models, click on a part number.
Mounting | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Holes | No. of Columns | No. of Rows | Ht. | Wd. | Dp. | Environment | Environmental Rating | Closure Screw Type | Fasteners Included | No. of Holes | Hole Dia. | Features | Specifications Met | Color | Each | |
Polycarbonate Plastic with Lift-Off Cover and Screw Closure | ||||||||||||||||
For 22 mm Push-Button | ||||||||||||||||
1 | 1 | 1 | 4 3/8" | 3 3/16" | 2 13/16" | Corrosive, Damp, Dusty, Oily, Outdoor, Submersible, Washdown | IP66; IP68; NEMA 6P; NEMA 12 | Captive | No | 2 | 0.13" | Gasketed Cover | UL Listed, C-UL Listed, CE Marked, UL 94 5VA | Yellow/Black | 00000000 | 000000 |
2 | 1 | 2 | 5 1/8" | 3 3/16" | 3 9/16" | Corrosive, Damp, Dusty, Oily, Outdoor, Submersible, Washdown | IP66; IP68; NEMA 6P; NEMA 12 | Captive | No | 2 | 0.13" | Gasketed Cover | UL Listed, C-UL Listed, CE Marked, UL 94 5VA | Yellow/Black | 00000000 | 00000 |
For 30 mm Push-Button | ||||||||||||||||
1 | 1 | 1 | 4 3/8" | 3 3/16" | 2 13/16" | Corrosive, Damp, Dusty, Oily, Outdoor, Submersible, Washdown | IP66; IP68; NEMA 6P; NEMA 12 | Captive | No | 2 | 0.13" | Gasketed Cover | UL Listed, C-UL Listed, CE Marked, UL 94 5VA | Yellow/Black | 00000000 | 00000 |
2 | 1 | 2 | 5 1/8" | 3 3/16" | 3 9/16" | Corrosive, Damp, Dusty, Oily, Outdoor, Submersible, Washdown | IP66; IP68; NEMA 6P; NEMA 12 | Captive | No | 2 | 0.13" | Gasketed Cover | UL Listed, C-UL Listed, CE Marked, UL 94 5VA | Yellow/Black | 00000000 | 00000 |
High-Visibility Enclosures
House emergency stop buttons, life safety equipment, and other devices that need to be seen with these brightly colored enclosures, which are easy to spot even in high-dust areas. Made of polycarbonate, they resist denting, cracking, and chipping as well as fading from UV rays. They’re rust resistant, and more chemical resistant than fiberglass and metal enclosures. These enclosures don’t block wireless or radio signals, so they’re good for use with Wi-Fi-enabled components
Add panels as interior mounting surfaces that don’t require you drilling holes in your enclosure’s wall and compromising its environmental rating. Use them as a surface for assembling electronics outside the enclosure, then install them when work is finished.
For technical drawings and 3-D models, click on a part number.
Enclosures | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mounting | Panels | ||||||||||||
Height | Width | Depth | Environment | Environmental Rating | Includes | Number of Holes | Hole Diameter | For Maximum Padlock Shackle Diameter | Specifications Met | Each | Each | ||
Polycarbonate Plastic with Hinged Cover and Quick-Release Latch | |||||||||||||
Red | |||||||||||||
13 1/16" | 11" | 6 11/16" | Corrosive, Damp, Dusty, Outdoor, Submersible, Washdown | IP66; IP67; NEMA 6P | Mounting Hardware | 4 | 1/4" | __ | CE Marked, UL 508 | 0000000 | 0000000 | 00000000 | 000000 |
15 1/8" | 13" | 7 3/4" | Damp, Dusty, Outdoor, Submersible, Washdown | IP66; IP67; NEMA 4X | Mounting Hardware | 4 | 1/4" | __ | CE Marked, UL 508 | 0000000 | 000000 | 00000000 | 00000 |
Yellow | |||||||||||||
13 1/16" | 11" | 6 11/16" | Corrosive, Damp, Dusty, Outdoor, Submersible, Washdown | IP66; IP67; NEMA 6P | Mounting Hardware | 4 | 1/4" | 3/8" | CE Marked, UL 508 | 0000000 | 000000 | 00000000 | 00000 |
15 1/8" | 13" | 7 3/4" | Damp, Dusty, Outdoor, Submersible, Washdown | IP66; IP67; NEMA 4X | Mounting Hardware | 4 | 1/4" | 3/8" | CE Marked, UL 508 | 0000000 | 000000 | 00000000 | 00000 |
Console Enclosures
Build out human-machine interfaces by installing buttons, switches, gauges, and other components to monitor and control machinery. These enclosures have a large, slanted cover that holds components at a visible angle without blocking the view of your operation. They are about countertop height, so you can sit or stand during use. Remove the cover and doors to assemble electronics with more working space. They are IP and NEMA rated for protection from washdowns, oil, and dust.
Choose enclosures with rear access doors for another access point to internal electronics. They have panel mounting channels, so you can position panels (sold separately) at different depths, creating more space for components.
Add panels inside the enclosure to mount electronics without cutting or drilling the walls, maintaining protection from washdowns, oil, and dust. Electronics can be assembled on the panel outside of the enclosure for more working space and inserted when complete.
Replacement covers (sold separately) allow you to repurpose the enclosure for operations with different layouts.
For technical drawings and 3-D models, click on a part number.
Ht. | Front Ht. | Wd. | Dp. | Slant Length | Slope Angle | Lock Location | Number of Locks | Number of Keys Included | Environmental Rating | Includes | Features | Specifications Met | Color | Each | |
Powder-Coated Steel | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
One Door | |||||||||||||||
40 1/4" | 32 1/8" | 25 1/4" | 21 1/2" | 21 5/8" | 25° | Front Access Door | 1 | 2 | IP66, NEMA 4, NEMA 13 | Document Holder | Gasketed Cover, Removable Cover, Front Access Door, Removable Doors, Drain, Concealed Hinge | UL Listed, C-UL Listed | Gray | 0000000 | 000000000 |
Two Doors | |||||||||||||||
47 1/8" | 36 3/4" | 25 1/4" | 24 1/2" | 24 7/8" | 25° | Front Access Door, Rear Access Door | 2 | 4 | IP66, NEMA 4, NEMA 13 | Document Holder | Panel Mounting Channels, Gasketed Cover, Removable Cover, Front Access Door, Rear Access Door, Removable Doors, Drain, Concealed Hinge | UL Listed, C-UL Listed | Gray | 0000000 | 00000000 |
Four Doors | |||||||||||||||
47 1/8" | 36 3/4" | 49 1/4" | 24 1/2" | 24 7/8" | 25° | Front Access Door, Rear Access Door | 4 | 8 | IP66, NEMA 4, NEMA 13 | Document Holder | Panel Mounting Channels, Gasketed Cover, Removable Cover, Front Access Door, Rear Access Door, Removable Doors, Drain, Concealed Hinge | UL Listed, C-UL Listed | Gray | 0000000 | 00000000 |
Mounting Hole Center-to-Center | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Color | Material | Ht. | Wd. | Ht. | Wd. | Thickness | Mounting Fasteners Included | Number of Mounting Holes | Mounting Hole Dia. | For Mounting Fastener Screw Size | Each | |
For Enclosures with One Door | ||||||||||||
White | Powder-Coated Steel | 27" | 21" | 25 1/4" | 19 1/4" | 0.12" | No | 4 | 1/2" | 3/8" | 00000000 | 000000 |
For Enclosures with Two Doors | ||||||||||||
White | Powder-Coated Steel | 33" | 21" | 31 1/4" | 19 1/4" | 0.12" | No | 6 | 1/2" | 3/8" | 00000000 | 000000 |
For Enclosures with Four Doors | ||||||||||||
White | Powder-Coated Steel | 45" | 33" | 43 1/4" | 31 1/4" | 0.12" | No | 8 | 1/2" | 3/8" | 00000000 | 000000 |