Galvanized Steel | ||||||
---|---|---|---|---|---|---|
Duct Size | ID | Lg. | Gauge | End Construction | Each | |
22 | 21 7/8" | 58 3/4" | 20 | Rolled | 00000000 | 0000000 |

Duct with access panel saves you from having to cut holes or add screws for a traditional cleanout door. The built-in panel slides back and forth, giving you easy access to the inside of the duct.
Opening | Galvanized Steel | |||||||
---|---|---|---|---|---|---|---|---|
Duct Size | ID | Lg. | Wd. | Lg. | Gauge | End Construction | Each | |
22 | 22" | 58 3/4" | 7" | 14" | 20 | Rolled | 00000000 | 0000000 |

Galvanized Steel | ||
---|---|---|
Duct Size | Each | |
22 | 00000000 | 000000 |

Galvanized Steel | ||||||
---|---|---|---|---|---|---|
Duct Size | ID | End Construction | Style | Gauge | Each | |
22 | 22" | Rolled | B | 20 | 00000000 | 0000000 |

Tee connectors join or split runs of duct.
Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | ID | Gauge | End Construction | Each | |
22 | 21 7/8" | 20 | Rolled | 00000000 | 0000000 |

Wye connectors join or split runs of duct.
Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | ID | Gauge | End Construction | Each | |
22 | 22" | 20 | Rolled | 00000000 | 0000000 |

Wye connectors join or split runs of duct.
Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | ID | Gauge | End Construction | Each | |
22 | 21 7/8" | 20 | Rolled | 00000000 | 0000000 |



Adapters join quick-disconnect duct to other duct systems. Duct-to-duct with flange adapters provide a secure connection between duct. Duct flanges are also available. Duct-to-hose adapters are slightly undersized. Slide hose over the adapter and hold it in place with a hose clamp (not included).

Airflow dampers regulate airflow.
Galvanized Steel | ||||||
---|---|---|---|---|---|---|
Duct Size | ID | Gauge | End Construction | Blade Material | Each | |
22 | 22 1/8" | 20 | Rolled | Galvanized Steel | 00000000 | 0000000 |

Blast gates stop airflow when closed.
Aluminum | |||||
---|---|---|---|---|---|
Duct Size | ID | End Construction | Blade Material | Each | |
22 | 22" | Rolled | Galvanized Steel | 00000000 | 0000000 |

Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Sound Absorbed | Gauge | End Construction | Each | |
22 | 25% | 20 | Rolled | 00000000 | 000000000 |

Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | ID | Gauge | End Construction | Each | |
22 | 21 7/8" | 20 | Rolled | 00000000 | 000000 |
Standard Duct and Fittings

No need for clamps or connectors—duct and fittings press-fit together. Male ends are crimped or tapered, making them slightly smaller than a female end for simple assembly.
Galvanized steel has good corrosion resistance.
For technical drawings and 3-D models, click on a part number.

Connectors with welded seams prevent leaks.
Galvanized Steel | |||||||
---|---|---|---|---|---|---|---|
Duct Size | Female ID | Male OD | Features | End Construction | Gauge | Each | |
22 | 22" | 21 7/8" | Welded Seams | Tapered | 20 | 00000000 | 0000000 |

Galvanized Steel | ||||||
---|---|---|---|---|---|---|
Duct Size | Female ID | Male OD | End Construction | Gauge | Each | |
22 | 22" | 21 7/8" | Crimped | 24 | 00000000 | 0000000 |

Straight connectors wrap around two female duct ends to join them.
Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Female ID | Gauge | End Construction | Each | |
22 | 22" | 26 | Plain | 00000000 | 000000 |

Galvanized Steel | ||||||
---|---|---|---|---|---|---|
Duct Size | Female ID | Male OD | Gauge | End Construction | Each | |
Female × Female × Male | ||||||
22 | 22" | 21 7/8" | 22 | Crimped | 00000000 | 0000000 |

Reducers connect duct with different diameters.
Duct Size | Galvanized Steel | ||||||
---|---|---|---|---|---|---|---|
(A) | (B) | Female ID (A) | Male OD (B) | End Construction | Gauge | Each | |
22 | 18 | 22" | 17 7/8" | Plain | 24 | 00000000 | 0000000 |

Airflow dampers control airflow through duct.
Galvanized Steel | ||||||
---|---|---|---|---|---|---|
Duct Size | Male OD | Gauge | End Construction | Blade Material | Each | |
Standard | ||||||
22 | 21 3/4" | 18 | Plain | Galvanized Steel | 00000000 | 0000000 |
Crush-Resistant Spiral Duct and Fittings

A spiral seam makes this duct strong and rigid. Fittings have male ends with a slightly smaller diameter to press-fit into duct.
Galvanized steel has good corrosion resistance.
For technical drawings and 3-D models, click on a part number.

Add a noise reducer to duct to decrease noise by as much as 50%.

Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Male OD | Gauge | End Construction | Each | |
22 | 21 7/8" | 22 | Spiral | 00000000 | 0000000 |

Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Male OD | Gauge | End Construction | Each | |
22 | 21 7/8" | 24 | Spiral | 00000000 | 0000000 |

Tee connectors join or split runs of duct.
Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Male OD | Gauge | End Construction | Each | |
22 | 21 7/8" | 22 | Plain | 00000000 | 0000000 |

Wye connectors join or split runs of duct.
Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Male OD | Gauge | End Construction | Each | |
22 | 21 7/8" | 24 | Plain | 00000000 | 0000000 |


Collars create branches from a rectangular duct. Cut a hole in the duct and use a collar to attach spiral duct.

Galvanized Steel | |||||
---|---|---|---|---|---|
Duct Size | Male OD | Gauge | End Construction | Each | |
Male | |||||
22 | 21 7/8" | 24 | Spiral | 00000000 | 000000 |
Duct Flanges
Bolt flanges to equipment to start a run of duct. They can also create secure connections between two duct ends by mounting a flange to each end and then joining the flanges.
Steel, galvanized steel, 304 stainless steel, and aluminum flanges are also known as angle rings.
Galvanized steel flanges have good corrosion resistance.304 stainless steel flanges are more corrosion resistant than steel.
For technical drawings and 3-D models, click on a part number.

Steel, 304 Stainless
Steel, and Aluminum

Flange | Mounting | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Duct Size | Female ID | Overall Dp. | Ht. | Thick. | Fasteners Included | No. of Holes | Hole Dia. | Connection Type | Each | |
Steel | ||||||||||
22 | 22 1/8" | 1 1/2" | 1 1/2" | 3/16" | No | 12 | 7/16" | Press Fit | 0000000 | 000000 |
Galvanized Steel | ||||||||||
22 | 22 1/8" | 1 1/2" | 1 1/2" | 3/16" | No | 12 | 7/16" | Press Fit | 0000000 | 00000 |
304 Stainless Steel | ||||||||||
22 | 22 1/8" | 1 1/2" | 1 1/2" | 3/16" | No | 12 | 7/16" | Press Fit | 0000000 | 000000 |
Weld-On Duct Flanges


Weld flanges to equipment to start a run of duct. They can also create secure connections between two duct ends by mounting a flange to each end and then joining the flanges. Also known as angle rings.
304 stainless steel flanges are more corrosion resistant than steel.
For technical drawings and 3-D models, click on a part number.