Double-Wall Plastic Tanks
No need for separate spill-control pallets or trays—comply with EPA regulations for storing hazardous liquids with just one tank. These tanks have two walls, so if the primary compartment ruptures, the secondary one will contain the leak. It can hold 110% of the primary tank's volume and will also protect it from damage in case of impact.
Made of polyethylene, these tanks can store a broader range of chemicals than steel double-wall tanks. The plastic contains UV inhibitors so they can be used outside.
These tanks have a flat space on top where you can mount a metering pump. Because these tanks meet NSF/ANSI 61 for drinking water, you can meter chemicals stored in them into your drinking water system.
For technical drawings and 3-D models, click on a part number.
Cap., gal. | Wd. | Dp. | Ht. | Primary Compartment Opening (No. of) | Secondary Compartment Opening (No. of) | Color | Max. Temp., °F | Specifications Met | Includes | Each | |
Polyethylene Plastic | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
10 | 14" | 14" | 22" | 4" Fill Opening Dia. (1) 3/8" Opening Dia. (1) 2 NPT Female Opening (1) | 1 NPT Female Opening (1) | Blue | 130° | EPA 40 CFR 264.175 NSF/ANSI 61 | Vented Fill Cap | 0000000 | 0000000 |
20 | 18" | 18" | 24" | 8" Fill Opening Dia. (1) 3/8" Opening Dia. (1) 2 NPT Female Opening (2) | 1 NPT Female Opening (1) | Blue | 130° | EPA 40 CFR 264.175 NSF/ANSI 61 | Vented Fill Cap | 0000000 | 000000 |
40 | 20" | 20" | 38" | 8" Fill Opening Dia. (1) 3/8" Opening Dia. (1) 2 NPT Female Opening (2) | 1 NPT Female Opening (1) | Blue | 130° | EPA 40 CFR 264.175 NSF/ANSI 61 | Vented Fill Cap | 0000000 | 00000000 |
70 | 24" | 24" | 41" | 8" Fill Opening Dia. (1) 3/8" Opening Dia. (1) 2 NPT Female Opening (2) | 1 NPT Female Opening (1) | Blue | 130° | EPA 40 CFR 264.175 NSF/ANSI 61 | Vented Fill Cap | 0000000 | 00000000 |
Double-Wall Steel Tanks with Forklift Entry
Provide extra protection for products that require double-wall containment, such as diesel and waste oil, solvents, and antifreeze. The tank's second wall forms a spill-control compartment that holds 110% of the primary compartment's storage capacity. They have an opening for venting in the primary compartment, an opening for leak detection in the secondary compartment, and two openings for emergency venting in the primary and secondary compartments.
For technical drawings and 3-D models, click on a part number.
Max. Fork | Primary Compartment Openings | Secondary Compartment Openings | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity, gal. | Wd. | Dp. | Ht. | Gauge | No. of Entry Points for Forklifts | Wd. | Ht. | Color | Pipe Size (No. of) | Gender | Pipe Size (No. of) | Gender | Specifications Met | Each | |
Powder-Coated Steel | |||||||||||||||
120 | 34" | 29" | 37 1/2" | 12 | 2 | 19" | 1 1/2" | White | 2 NPT (5) | Female | 2 NPT (2) | Female | UL 142 | 0000000 | 000000000 |
240 | 55" | 34" | 37 1/2" | 12 | 2 | 40" | 1 1/2" | White | 2 NPT (5), 3 NPT (1) | Female | 2 NPT (1), 3 NPT (1) | Female | UL 142 | 0000000 | 00000000 |