Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included). They’re rated IP65 for protection from washdowns.
For technical drawings and 3-D models, click on a part number.
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Dp. Behind Panel | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Stays Switched (Maintained) | ||||||||
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 000000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 000000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 000000000 | 000000 |
Yellow Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
4 Circuits with Lockout—For 3/8" Panel Cutout Dia. | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 3 1/4" | 2 1/2" | 1 13/16" | UL Recognized Component, UL 508 | 00000000 | 00000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4" | 3 1/8" | 2" | UL Recognized Component, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (7 1/2 hp @ 120 V AC) Three (15 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 4" | 3 1/8" | 3 3/16" | UL Recognized Component, UL 508 | 00000000 | 000000 |
Enclosed Compact Disconnect Switches

Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Their polycarbonate housing protects the switch and resists denting, chipping, and cracking. Rated IP65, the housing also seals out water even in frequently washed down areas. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Yellow Plastic Housing with Red Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||
4 Circuits with Lockout | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 0000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
Harsh Environment Panel-Mount Disconnect Switches


Rated IP69K, these switches withstand high-pressure, high-temperature washdowns. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Dia. | Ht. | Wd. | Dp. Behind Panel | Each | ||
Yellow Stainless Steel Housing with Red Actuator | |||||||||||
4 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
A | 20 | 300V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 3 15/16" | __ | __ | 3 3/8" | 00000000 | 0000000 |
Gray Stainless Steel Housing with Gray Actuator | |||||||||||
4 Circuits with Lockout—For 7/8" Panel Cutout Dia. | |||||||||||
C | 20 | 300V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 240 V AC) | __ | 3 1/8" | 2 3/4" | 3 3/8" | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
DIN-Rail Mount Disconnect Switches
Often used in electrical enclosures, these switches mount directly to DIN rails. They cut power and keep it isolated to stop equipment from starting up during inspection and maintenance. For an extra level of security, add a padlock (not included) to lock out the actuator lever in the Off position.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control additional circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
For technical drawings and 3-D models, click on a part number.

Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | For Max. Padlock Shackle Dia. | For DIN Rail Ht., mm | Wire Connection Type | Specifications Met | Each | |
Gray Plastic Housing with Black Actuator | ||||||||||||
4 Circuits with Lockout | ||||||||||||
25 | 600V AC | Stays Switched (Maintained) | 4PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 4PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 3" | 1 3/4" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
50 | 600V AC | Stays Switched (Maintained) | 4PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 3/8" | 2 1/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 00000 |
63 | 600V AC | Stays Switched (Maintained) | 4PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 3 3/8" | 2 1/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
80 | 600V AC | Stays Switched (Maintained) | 4PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 3 3/4" | 2 7/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |
100 | 600V AC | Stays Switched (Maintained) | 4PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 3 3/4" | 2 7/8" | 5/16" | 35 | Screw Terminals | UL Listed, C-UL Listed, CE Marked, UL 508 | 0000000 | 000000 |

Switching Current, A | Each | |
10 | 0000000 | 000000 |