Switching | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Each | |
Plastic Housing with Red Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 0000000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
2 Circuits with Lockout | ||||||||
20 | 800V DC | DPST | __ | 9 13/16" | 6 5/16" | IP66 | 0000000 | 000000 |
32 | 800V DC | DPST | __ | 11" | 7 1/2" | IP66, IP67, NEMA 3S, NEMA 6P, NEMA 12 | 0000000 | 000000 |
50 | 800V DC | DPST | __ | 12 5/8" | 8 11/16" | IP65, NEMA 3R | 0000000 | 000000 |
63 | 650V DC | DPST | __ | 12 5/8" | 8 11/16" | IP65, NEMA 3R | 0000000 | 000000 |
Plastic Housing with Gray Actuator | ||||||||
Stays Switched (Maintained) | ||||||||
3 Circuits | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
50 | 600V AC | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
63 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (10 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
80 | 600V AC | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
100 | 600V AC | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 8 11/16" | 5 7/8" | IP40, NEMA 3 | 00000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Washdown Enclosed Disconnect Switches
The IP66 rated housing not only shields these switches from washdowns but also makes them durable enough to be mounted outside of an electrical panel. These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||
---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Each | |
Plastic Housing with Red Actuator | ||||||||
3 Circuits | ||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 0000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
20 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1/3 hp @ 120 V AC) Single (3/4 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 6 7/8" | 4 1/2" | 0000000 | 00000 |
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 6 7/8" | 4 1/2" | 0000000 | 00000 |
63 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 11" | 7 1/2" | 0000000 | 000000 |
80 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 11" | 7 1/2" | 0000000 | 000000 |
100 | 600V AC | Stays Switched (Maintained) | 3PST | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (25 hp @ 240 V AC) | 11" | 7 1/2" | 0000000 | 000000 |
Plastic Housing with Gray Actuator | ||||||||
3 Circuits | ||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 4 5/16" | 00000000 | 000000 |
3 Circuits with Lockout | ||||||||
25 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (3 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
32 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 5 7/8" | 3 7/8" | 00000000 | 000000 |
Stainless Steel Housing with Red Actuator | ||||||||
3 Circuits with Lockout | ||||||||
20 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1/3 hp @ 120 V AC) Single (1 hp @ 240 V AC) Three (2 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 000000 | 000000 |
30 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (5 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
40 | 600V AC | Stays Switched (Maintained) | 3PST | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
60 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (7 1/2 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
80 | 600V AC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (20 hp @ 240 V AC) | 7 7/8" | 5 15/16" | 0000000 | 000000 |
"Main Switch" Label with Adhesive Back—13/16" Ht. × 3 3/16" Wd. | 0000000 | Each | 000000 |
For Switching Current | Housing Color | Actuator Color | Ht. | Wd. | Dp. | Each | |
25A, 32A, 50A, 63A | Yellow | Red | 2 9/16" | 2 9/16" | 1 5/16" | 0000000 | 000000 |
Switching Current, A | Each | |
10 | 0000000 | 000000 |
Switching Current, A | Specifications Met | Each | |
20 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
25 | UL Listed, CE Marked | 00000000 | 00000 |
30 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
32 | UL Listed, CE Marked | 00000000 | 00000 |
40 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
60 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
80 | UL Listed, C-UL Listed, CE Marked | 00000000 | 00000 |
For Current, A | Specifications Met | Each | |
25/32 | UL Listed, CE Marked | 00000000 | 000000 |
Durable Disconnect Switches
Protected by a steel enclosure, these switches withstand tougher conditions than switches in a plastic housing. Also known as safety switches, they have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Switches with safety interlock keep the door closed when the switch is on and prevent the switch from turning on when the door is open.
Switches with a fuse holder are used where overload protection is needed. When the current exceeds the fuse’s rating, the fuse will blow, interrupting the circuit to prevent the switch from overheating, breaking, or causing a fire. These switches require rejection-style fuse clips when used with UL Class RK1, RK5, or T fuses. Note: Horsepower ratings are based on time-delay fuses installed.
Switches with a viewing window let you see if the fuses have blown without opening the enclosure.
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Rejection-Style Fuse Clips for RK1 and RK5 Fuse Class | |||||||||||||
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Environmental Rating | Specifications Met | Each | Each | ||
Enamel-Coated Steel with Black Actuator | ||||||||||||||
3 Circuits with Lockout, Safety Interlock | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 600 V AC) Single (5 hp @ 240 V AC) Single (7 1/2 hp @ 480 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 0000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 240 V AC) Single (25 hp @ 480 V AC) Single (30 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (20 hp @ 240 V AC) Single (40 hp @ 480 V AC) Single (40 hp @ 600 V AC) | 3 | __ | 29 15/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (3 hp @ 240 V AC) Three (5 hp @ 480 V AC) Three (7 1/2 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (5 hp @ 480 V AC) Three (15 hp @ 480 V AC) Three (15 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PDT | Single (10 hp @ 480 V AC) Three (25 hp @ 480 V AC) Three (30 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 38 7/16" | 12" | NEMA 1 | UL Listed | 000000 | 00000000 | 000000 | 00 |
Enamel-Coated Steel with Black/Red Actuator | ||||||||||||||
3 Circuits with Lockout, Safety Interlock, Viewing Window | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 600 V AC) Three (30 hp @ 600 V AC) | 3 | __ | 14 5/8" | 7 9/16" | NEMA 1 | UL Listed, CSA Certified, Fed. Spec. WS-865C | 0000000 | 000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (30 hp @ 600 V AC) Three (60 hp @ 600 V AC) | 3 | __ | 18 1/8" | 9" | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder, Viewing Window | ||||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 14 5/8" | 7 9/16" | NEMA 1 | UL Listed, CSA Certified, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 000000 |
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 4 | RK1, RK5, J, K5, H | 14 5/8" | 7 9/16" | NEMA 1 | UL Listed, CSA Certified, Fed. Spec. WS-865C | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 3 | RK1, RK5, J, K5, H | 18 1/8" | 9" | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 4 | RK1, RK5, J, K5, H | 18 1/8" | 9" | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 | 00000000 | 00000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (75 hp @ 600 V AC) | 4 | RK1, RK5, J, K5, H | 21 7/8" | 9" | NEMA 1 | UL Listed, CSA Certified | 0000000 | 000000 | 00000000 | 00000 |
200 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (150 hp @ 600 V AC) | 4 | RK1, RK5, J, K5, H | 29" | 17" | NEMA 1 | UL Listed, CSA Certified | 0000000 | 00000000 | 00000000 | 00000 |
Powder-Coated Steel with Red Actuator | ||||||||||||||
2 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 14 1/4" | 6 5/8" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (15 hp @ 240 V AC) | 3 | RK1, RK5, K5, T, H | 23 1/8" | 11 3/4" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
2 Circuits with Lockout, Fuse Holder | ||||||||||||||
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (10 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout, Safety Interlock | ||||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 3 | __ | 23 1/8" | 11 3/4" | NEMA 1 | UL Listed | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 14 1/4" | 6 5/8" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 4 | RK1, RK5, K5, T, H | 23 1/8" | 11 3/4" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout, Fuse Holder | ||||||||||||||
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | NEMA 1 | UL Listed | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout | ||||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 3 | __ | 6 3/8" | 4 9/16" | NEMA 1 | UL Listed | 0000000 | 00000 | 000000 | 00 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (15 hp @ 240 V AC) | 3 | __ | 8 9/16" | 5 7/16" | NEMA 1 | UL Listed | 0000000 | 000000 | 000000 | 00 |
Rejection-Style Fuse Clip for T Fuse Class | 00000000 | Each | 000000 |
Outdoor Durable Disconnect Switches
A raintight NEMA 3R rated enclosure protects these switches from falling liquids and light splashing. The enclosure is steel, so it withstands tougher conditions than plastic enclosures. All have quick-make/quick-break action to eliminate arcing and prolong switch life. They have a lockout to secure in the off position using a padlock (not included).
Switches with safety interlock keep the door closed when the switch is on, and prevent the switch from turning on when the door is open.
Use switches with a fuse holder where overload protection is needed. When the current exceeds the rating of the fuse, it blows. This interrupts the circuit and prevents overheating, damage, and fire. When used with UL Class RK1, RK5, or T fuses, they require rejection-style fuse clips. Note: Horsepower ratings are based on time-delay fuses installed.
Switches with a viewing window let you see if the fuses have blown without having to open the enclosure.
For technical drawings and 3-D models, click on a part number.
Switches | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Rejection-Style Fuse Clips for RK1 and RK5 Fuse Class | |||||||||||
Current, A | Voltage | Switch Action | Industry Designation | Electrical Phase (hp) | For No. of Wires | For Fuse Class | Ht. | Wd. | Each | Each | ||
Gray Enamel-Coated Steel with Black/Red Actuator | ||||||||||||
3 Circuits with Lockout, Safety Interlock, Viewing Window | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (30 hp @ 600 V AC) | 3 | __ | 15" | 7 3/4" | 0000000 | 0000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder, Viewing Window | ||||||||||||
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 3 | RK1, RK5, J, H | 15" | 7 3/4" | 0000000 | 000000 | 00000000 | 000000 |
30 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (20 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 15" | 7 3/4" | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Single (30 hp @ 240 V AC) Three (60 hp @ 600 V AC) | 3 | __ | 18 1/2" | 9 1/16" | 0000000 | 000000 | 000000 | 00 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 3 | RK1, RK5, J, H | 17 1/2" | 10 1/2" | 0000000 | 000000 | 00000000 | 00000 |
60 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (50 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 18 1/2" | 9 1/16" | 0000000 | 000000 | 00000000 | 00000 |
100 | 600V AC/ 600V DC | Stays Switched (Maintained) | 3PST | Three (75 hp @ 600 V AC) | 4 | RK1, RK5, J, H | 22 1/8" | 9 1/16" | 0000000 | 00000000 | 00000000 | 00000 |
Gray Powder-Coated Steel with Red Actuator | ||||||||||||
2 Circuits with Lockout, Fuse Holder | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (3 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 8 9/16" | 5 7/16" | 0000000 | 000000 | 00000000 | 000000 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (10 hp @ 240 V AC) | 3 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | 0000000 | 000000 | 00000000 | 00000 |
2 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | DPST | Single (15 hp @ 240 V AC) | 3 | RK1, RK5, K5, T, H | 23 1/8" | 12" | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (7 1/2 hp @ 240 V AC) | 3 | __ | 6 3/8" | 4 9/16" | 0000000 | 000000 | 000000 | 00 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (15 hp @ 240 V AC) | 3 | __ | 8 9/16" | 5 7/16" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Fuse Holder | ||||||||||||
30 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (3 hp @ 240 V AC) Three (7 1/2 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 8 9/16" | 5 7/16" | 0000000 | 000000 | 00000000 | 000000 |
60 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (10 hp @ 240 V AC) Three (15 hp @ 240 V AC) | 4 | RK1, RK5, K5, H | 10 1/16" | 6 7/16" | 0000000 | 000000 | 00000000 | 00000 |
3 Circuits with Lockout, Safety Interlock | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Three (30 hp @ 240 V AC) | 3 | __ | 23 1/8" | 12" | 0000000 | 000000 | 000000 | 00 |
3 Circuits with Lockout, Safety Interlock, Fuse Holder | ||||||||||||
100 | 240V AC/ 250V DC | Stays Switched (Maintained) | 3PST | Single (15 hp @ 240 V AC) Three (30 hp @ 240 V AC) | 4 | RK1, RK5, K5, T, H | 23 1/8" | 12" | 0000000 | 000000 | 00000000 | 00000 |
Rejection-Style Fuse Clip for T Fuse Class | 00000000 | Each | 000000 |
Enclosure Disconnect Switches
Install these switches inside an enclosure to prevent it from opening when power is on—turn the switch to disconnect power and release the door. Cut the shaft to fit the enclosure. Use a padlock (not included) to lock switches in the off position. Mount to DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail. UL listed, C-UL listed, and CE marked, these switches meet American, Canadian, and European safety standards.
Use optional sealing gaskets in washdown environments; they create an IP65 rated seal around the actuator.
Add auxiliary contact blocks to send a signal or connect to another device, such as an alarm or indicating light.
Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
Add junction blocks to connect a ground wire.
Terminal covers prevent contact with live terminals.
Switching | |||||||||
---|---|---|---|---|---|---|---|---|---|
Current, A | Voltage | Electrical Phase (hp) | Ht. | Wd. | For DIN Rail Ht., mm | Mounting Dp. | Environmental Rating | Each | |
Yellow Plastic Housing with Red Actuator | |||||||||
3 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 000000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 00000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 |
4 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 000000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 |
Gray Plastic Housing with Gray Actuator | |||||||||
3 Circuits with Lockout—For 1 3/16" Panel Cutout Dia. | |||||||||
25 | 600V AC | Single (3/4 hp @ 120 V AC) Single (1 1/2 hp @ 240 V AC) Three (1 1/2 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 |
32 | 600V AC | Single (1 hp @ 120 V AC) Single (2 hp @ 240 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 4 7/8"-15 3/4" | IP40 | 0000000 | 00000 |
50 | 600V AC | Single (1 1/2 hp @ 120 V AC) Single (3 hp @ 240 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 00000 |
63 | 600V AC | Single (3 hp @ 120 V AC) Single (5 hp @ 240 V AC) Three (5 hp @ 120 V AC) Three (10 hp @ 240 V AC) | 2 5/8" | 2 5/8" | 35 | 5 5/16"-16 1/8" | IP40 | 0000000 | 000000 |
80 | 600V AC | Single (3 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 |
100 | 600V AC | Single (5 hp @ 120 V AC) Single (10 hp @ 240 V AC) Three (10 hp @ 120 V AC) Three (25 hp @ 240 V AC) | 3 3/8" | 3 3/8" | 35 | 5 11/16"-16 1/2" | IP40 | 0000000 | 000000 |
Enclosed Compact Disconnect Switches
Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Their polycarbonate housing protects the switch and resists denting, chipping, and cracking. Rated IP65, the housing also seals out water even in frequently washed down areas. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. All have a lockout, so you can secure them in the off position with a padlock (not included).
For technical drawings and 3-D models, click on a part number.
Yellow Plastic Housing with Red Actuator | ||||||||
---|---|---|---|---|---|---|---|---|
Switching Current @ Voltage | Industry Designation | Electrical Phase (hp) | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||
3 Circuits with Lockout | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 3PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 0000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 3PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 3PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 3PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 3PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 3PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified, UL 508 | 00000000 | 000000 |
4 Circuits with Lockout | ||||||||
12 A @ 600 V AC, 16 A @ 24 V DC | 4PST | Single (1/2 hp @ 120 V AC) Three (1 hp @ 120 V AC) Three (3 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
16 A @ 600 V AC, 20 A @ 24 V DC | 4PST | Single (1 hp @ 120 V AC) Three (2 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
20 A @ 600 V AC, 25 A @ 24 V DC | 4PST | Single (1 1/2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (5 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
25 A @ 600 V AC, 32 A @ 24 V DC | 4PST | Single (2 hp @ 120 V AC) Three (3 hp @ 120 V AC) Three (7 1/2 hp @ 240 V AC) | 4 3/4" | 3 13/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
50 A @ 600 V AC, 50 A @ 24 V DC | 4PST | Single (3 hp @ 120 V AC) Three (15 hp @ 240 V AC) Three (7 1/2 hp @ 120 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
63 A @ 600 V AC, 80 A @ 24 V DC | 4PST | Single (5 hp @ 120 V AC) Three (10 hp @ 120 V AC) Three (20 hp @ 240 V AC) | 5 5/16" | 6 11/16" | IP65 | UL Recognized Component, CSA Certified | 00000000 | 000000 |
Automatic Transfer Switches
When the microcontroller inside detects a power outage, these switches automatically fire up a backup generator. They’ll switch back to utility power once power is restored. To prevent injury and damage to your generator, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching. These switches also have built-in overload protection, so they can isolate themselves from utility power to protect your facility. LED status lights let you know which power source is in use. Add a padlock (not included) to the lockout to prevent unauthorized changes to the switch. Rated NEMA 1, these switches should only be used indoors.
They're compatible with generators that have a two-wire remote starting system.
NEMA 3R doors make these switches safe for use outdoors since they seal out rain, snow, and sleet. These doors cover the LED status lights on the switch when closed.
For technical drawings and 3-D models, click on a part number.
Transfer Switches | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Housing | NEMA 3R Doors | ||||||||||||
Current | Voltage | Circuit Breaker Breakthrough Current | Industry Designation | Electrical Phase | For Number of Wires | Housing Material | Ht. | Wd. | Dp. | Specifications Met | Each | Each | ||
NEMA 1 | ||||||||||||||
2 Circuits | ||||||||||||||
100A | 120V AC | 10,000A | DPDT | Single | 4 | Aluminum | 27 1/4" | 18 7/8" | 8 1/4" | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000000 | 00000000 | 0000000 |
200A | 120V AC | 10,000A | DPDT | Single | 4 | Aluminum | 33" | 18 7/8" | 8 1/4" | UL Listed, UL 1008, NEC Article 702 | 0000000 | 00000000 | 00000000 | 000000 |
3 Circuits | ||||||||||||||
100A | 120V AC | 10,000A | 3PDT | Three | 6 | Aluminum | 27 1/4" | 18 7/8" | 8 1/4" | UL Listed, UL 1008, NEC Article 701 | 0000000 | 00000000 | 00000000 | 000000 |
200A | 120V AC | 10,000A | 3PDT | Three | 6 | Aluminum | 33" | 18 7/8" | 8 1/4" | UL Listed, UL 1008, NEC Article 701 | 0000000 | 00000000 | 00000000 | 000000 |
Manual Transfer Switches
If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
Use them with a portable generator.
NEMA 1 switches should be used indoors. Those with a power inlet box create a connection point between the switch and a portable generator. The inlet box is rated NEMA 3R, so it can be mounted on the outside of an exterior wall.
NEMA 3R switches can be used outdoors since they seal out rain, snow, and sleet.
Switches with a key lock prevent unauthorized changes to the switch.
Housing | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Power | Switching Current (No. of Switches) | Circuit Breaker Breakthrough Current | Electrical Phase | Housing Material | Ht. | Wd. | Dp. | Generator Connection Style | Power Cord Lg., ft. | Features | Specifications Met | Each | |
NEMA 1 | |||||||||||||
6 Circuits Total | |||||||||||||
7,500W | 30 A @ 240 V AC (1 DPDT) 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (2 SPDT) | 10,000A | Single | Powder-Coated Steel | 11 1/4" | 7 3/4" | 4 1/2" | NEMA L14-30 | __ | __ | UL Listed, UL 1008, NEC Article 702 | 0000000 | 0000000 |
12,500W | 30 A @ 240 V AC (1 DPDT) 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (2 SPDT) | 10,000A | Single | Powder-Coated Steel | 11 1/4" | 7 3/4" | 4 1/2" | CS6375 | __ | __ | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
10 Circuits Total | |||||||||||||
7,500W | 30 A @ 240 V AC (1 DPDT) 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (6 SPDT) | 10,000A | Single | Powder-Coated Steel | 11 1/4" | 11 3/4" | 4 1/2" | NEMA L14-30 | __ | __ | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
12,500W | 30 A @ 240 V AC (1 DPDT) 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (6 SPDT) | 10,000A | Single | Powder-Coated Steel | 11 1/4" | 11 3/4" | 4 1/2" | CS6375 | __ | __ | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
NEMA 1 with NEMA 3R Power Inlet Box | |||||||||||||
6 Circuits Total | |||||||||||||
7,500W | 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (4 SPDT) | 10,000A | Single | Powder-Coated Steel | 18" | 19" | 6" | NEMA L14-30 | 10 | __ | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
10 Circuits Total | |||||||||||||
7,500W | 20 A @ 240 V AC (1 DPDT) 20 A @ 120 VAC (2 SPDT) 15 A @ 120 V AC (6 SPDT) | 10,000A | Single | Powder-Coated Steel | 29" | 19" | 5" | NEMA L14-30 | 10 | __ | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
NEMA 3R | |||||||||||||
6 Circuits Total | |||||||||||||
7,500W | 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (4 SPDT) | 10,000A | Single | Powder-Coated Steel | 13" | 8" | 5" | NEMA L14-30 | __ | Key Lock | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
12,500W | 20 A @ 240 V AC (1 DPDT) 15 A @ 120 V AC (4 SPDT) | 10,000A | Single | Powder-Coated Steel | 13" | 8" | 5" | CS6375 | __ | Key Lock | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
10 Circuits Total | |||||||||||||
7,500W | 20 A @ 240 V AC (1 DPDT) 20 A @ 120 VAC (2 SPDT) 15 A @ 120 V AC (6 SPDT) | 10,000A | Single | Powder-Coated Steel | 13" | 12" | 5" | NEMA L14-30 | __ | Key Lock | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
12,500W | 20 A @ 240 V AC (1 DPDT) 20 A @ 120 VAC (2 SPDT) 15 A @ 120 V AC (6 SPDT) | 10,000A | Single | Powder-Coated Steel | 13" | 12" | 5" | CS6375 | __ | Key Lock | UL Listed, UL 1008, NEC Article 702 | 0000000 | 000000 |
Disconnect Enclosures
Keep enclosures locked until the power is cut. A multipoint latch connects to a flange-mount disconnect switch (not included) to hold the door closed, preventing potential electrical shock. All are IP or NEMA rated to keep out dust, dirt, and splashing water and oil. They meet Canadian and European safety standards; UL-listed enclosures also meet American safety standards.
Powder-Coated Steel—Include a removable panel, so you can mount components without drilling holes that might leak. Enclosures with two doors include a set of universal mounting plates, so they'll work with any flange-mounted disconnect switch. Both doors stay locked until the power is shut off.
Stainless Steel—Won't corrode from wet environments and harsh chemicals. Add a panel to mount components without drilling holes in the enclosure.
NEMA 4, NEMA 4X, and IP66 rated enclosures also protect what's inside from high-pressure washdowns.
For technical drawings and 3-D models, click on a part number.
Enclosures | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Mounting | Panels | ||||||||||
Height | Width | Depth | Environmental Rating | Fasteners Included | No. of Holes | Hole Dia. | Specifications Met | Each | Each | ||
Powder-Coated Steel | |||||||||||
1 Door | |||||||||||
20" | 21 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 0000000 | 000000 | 00 |
20" | 21 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
24" | 21 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
24" | 21 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
24" | 25 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
24" | 25 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
30" | 21 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
30" | 21 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
30" | 25 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
30" | 25 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
30" | 25 3/8" | 13" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
36" | 25 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
36" | 25 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 | 000000 | 00 |
36" | 31 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
36" | 31 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
36" | 31 3/8" | 13" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
36" | 31 3/8" | 17" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 31 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 31 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 31 3/8" | 13" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 31 3/8" | 17" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 37 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 37 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 37 3/8" | 13" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
42" | 37 3/8" | 17" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
48" | 25 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
48" | 37 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
48" | 37 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
48" | 37 3/8" | 13" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
48" | 37 3/8" | 17" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
60" | 37 3/8" | 8" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
60" | 37 3/8" | 11" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
60" | 37 3/8" | 13" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
60" | 37 3/8" | 17" | NEMA 4; NEMA 13; IP66 | No | 4 | 0.44" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
2 Door | |||||||||||
60 1/8" | 50" | 13 1/2" | NEMA 13; IP54 | No | 4 | 0.44" | CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
60 1/8" | 62" | 13 1/2" | NEMA 13; IP54 | No | 4 | 0.44" | CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
72 1/8" | 62" | 13 1/2" | NEMA 13; IP54 | No | 4 | 0.44" | CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
72 1/8" | 74" | 13 1/2" | NEMA 13; IP54 | No | 4 | 0.44" | CSA Certified, CE Marked | 0000000 | 00000000 | 000000 | 00 |
Stainless Steel | |||||||||||
1 Door | |||||||||||
20" | 22" | 9" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 00000000 | 000000 |
24" | 22" | 9" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 00000000 | 00000 |
24" | 26" | 9" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 00000000 | 00000 |
30" | 26" | 9" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 00000000 | 000000 |
36" | 26" | 9" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 0000000 | 000000 |
36" | 32" | 9" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 0000000 | 000000 |
42" | 32" | 13" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 0000000 | 000000 |
42" | 38" | 13" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 0000000 | 000000 |
48" | 38" | 13" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 0000000 | 000000 |
60" | 38" | 13" | NEMA 4X; NEMA 13; IP66 | No | 4 | 1/2" | UL Listed, CSA Certified, CE Marked | 0000000 | 00000000 | 0000000 | 000000 |