About Wire and Cable
More
Building Cable
- Use For:
NM-B, THHN: Buildings
UF-B, THHN: Buildings, Outdoors - Bend and Stay
- Temperature Range: 10° to 190° F
- Insulation: PVC Plastic
Rated for in-wall installation, this cable carries power to wall outlets. Also known as branch circuit wire, it can be used without conduit. It has solid THHN building wires, so the cable will stay in the shape you bend it. The uninsulated ground wire is not counted in the number of wires.
UF-B cable is for wet locations where cable may be exposed to moisture or humidity. It's often used as underground feeder cable for pumps and lighting. The insulation resists moisture and UV light.
Per Ft. | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | Wd. | Thick. | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-249 | 250-Up | |
UF-B, THHN Solid Wire | |||||||||||||
600V AC | |||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.42" | 0.17" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 00000 | 00000 | |
14 | 3 | 14/3 | 15 A @ 86° F | 0.58" | 0.17" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 000 | |
12 | 2 | 12/2 | 20 A @ 86° F | 0.46" | 0.18" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 20 A @ 86° F | 0.63" | 0.18" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
10 | 2 | 10/2 | 30 A @ 86° F | 0.52" | 0.22" | Gray | Black, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 30 A @ 86° F | 0.73" | 0.22" | Gray | Black, Red, White | Uninsulated Ground Wire | UL Listed, UL 493 | 0000000 | 0000 | 0000 |
Armored Building Cable
- Use For: Buildings
- Flexible
- Temperature Range:
MC, THHN: 15° to 190° F
MC, XHHW-2: -40° to 190° F - Outer Insulation:
MC, THHN: Aluminum Armor
MC, XHHW-2: Aluminum Armor, PVC Plastic - Inner Insulation:
MC, THHN: PVC Plastic
MC, XHHW-2: Cross-Linked Polyethylene (XLPE)
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has a ground wire that is not counted in the number of wires.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
Cable with XHHW-2 wire has a PVC outer jacket over the aluminum armor. You can use it in wet environments where liquid might drip and splash on it. It can also be used for direct burial without a conduit.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
MC, XHHW-2 Stranded Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC/600V DC | ||||||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.64" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.65" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
12 | 4 | 12/4 | 20 A @ 86° F | 0.68" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.7" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 | |||||
10 | 4 | 10/4 | 30 A @ 86° F | 0.74" | Black | Uninsulated Ground Wire | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Division 2 | UL 1569 | 0000000 |
Direct-Burial Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 140° F
Weather-resistant insulation makes this cable suitable for outdoor use and direct burial without conduit.
18-gauge wire is often used for sprinkler systems.
16-, 14-, and 12-gauge wire is designed for underground, low-voltage lighting equipment, such as landscape lighting. The wires can be separated for installation.
Wire Ga. | No. of Wires | Cable AWG | OD | Outer Insulation Color | Inner Insulation Material | Inner Insulation Color | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | 500 ft. | |
30V AC/30V DC | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
18 | 2 | 18/2 | 0.2" | Black | Polypropylene Plastic | Red, White | UL Listed | 0000000 | ||||||
18 | 3 | 18/3 | 0.21" | Black | Polypropylene Plastic | Green, Red, White | UL Listed | 0000000 | ||||||
18 | 4 | 18/4 | 0.23" | Black | Polypropylene Plastic | Blue, Green, Red, White | UL Listed | 0000000 | ||||||
18 | 5 | 18/5 | 0.25" | Black | Polypropylene Plastic | Blue, Green, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 6 | 18/6 | 0.27" | Black | Polypropylene Plastic | Blue, Brown, Green, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 7 | 18/7 | 0.27" | Black | Polypropylene Plastic | Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 8 | 18/8 | 0.29" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Red, White, Yellow | UL Listed | 0000000 | ||||||
18 | 9 | 18/9 | 0.31" | Black | Polypropylene Plastic | Black, Blue, Brown, Green, Orange, Pink, Red, White, Yellow | UL Listed | 0000000 |
Pump Cable
- Use For: Submersible Pumps, Outdoors
- Temperature Range: -55° to 140° F
Supply power to submersible pumps in water or oil wells. The TPE rubber insulation holds up to moisture, chemicals, oil, and UV light, so this cable can be used outdoors. Also known as twisted pump cable, it can be used in grounded or ungrounded water well cable systems. The insulated ground wire is not counted in the number of wires.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | |
Stranded Wire with TPE Rubber Outer Insulation | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.46" | Black, Green, Red, Yellow | Insulated Ground Wire | THW | UL Listed, UL 83 | 0000000 | ||||
10 | 3 | 10/3 | 20 A @ 86° F | 0.51" | Black, Green, Red, Yellow | Insulated Ground Wire | THW | UL Listed, UL 83 | 0000000 |
Water-Block Control Cable
- Use For: Buildings, Outdoors
- Flexible
- Temperature Range: 0° to 220° F
- Insulation:
Outer: Fiber; PVC Plastic
Inner: PVC Plastic
Keep water from damaging wires—this cable has a layer of absorbent material that traps moisture before it reaches the internal wires. Use it in washdown areas, indoor/outdoor transitions, and direct burial without conduit. It sends signal and data to operate, measure, or regulate automated equipment.
Per Ft. | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Features | Specifications Met | Length, ft. | 1-249 | 250-Up | |
Stranded Wire | ||||||||||||
300V AC | ||||||||||||
18 | 2 | 18/2 | 5 A @ 86° F | 0.22" | Black | Black, Red | Water-Absorbing Filler | UL Listed | 0000000 | 00000 | 00000 | |
18 | 4 | 18/4 | 7.2 A @ 86° F | 0.31" | Black | Black, Green, Red, White | Water-Absorbing Filler | UL Listed | 0000000 | 0000 | 000 | |
16 | 4 | 16/4 | 9 A @ 86° F | 0.34" | Black | Black, Green, Red, White | Water-Absorbing Filler | UL Listed | 0000000 | 0000 | 0000 | |
14 | 2 | 14/2 | 8 A @ 86° F | 0.29" | Black | Black, White | Water-Absorbing Filler | UL Listed | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 13 A @ 86° F | 0.43" | Black | Black, Green, Red, White | Water-Absorbing Filler | UL Listed | 0000000 | 0000 | 0000 | |
12 | 2 | 12/2 | 12 A @ 86° F | 0.32" | Black | Black, White | Water-Absorbing Filler | UL Listed | 0000000 | 0000 | 0000 |
UV-Resistant Wire
- Use for outdoors, buildings, solar equipment, power supply
- Flexible
- Temperature Range: -40° to 190° F
- Insulation: Cross-Linked Polyethylene (XLPE)
Also known as photovoltaic (PV) wire, this wire won’t deteriorate from UV light when used outdoors. Often used in solar panels, the cross-linked polyethylene (XPLE) insulation won’t break down from prolonged exposure to high temperatures. The insulation also resists chemicals. An RHW-2 industry designation means this wire withstands underground and wet locations.
For technical drawings and 3-D models, click on a part number.
Per Ft. | |||||||||
---|---|---|---|---|---|---|---|---|---|
Wire Ga. | Strand Count | Current | OD | Industry Designation | Specifications Met | Outer Insulation Color | 1-99 | 100-Up | |
Stranded Wire | |||||||||
12 | 56/29 | 55 A @ 86° F | 0.21" | PV, RHW-2 | UL Listed, UL 2556 VW-1 | Black | 0000000 | 00000 | 00000 |
10 | 84/29 | 70 A @ 86° F | 0.24" | PV, RHW-2 | UL Listed, UL 2556 VW-1 | Black | 0000000 | 0000 | 000 |
8 | 157/29 | 98 A @ 86° F | 0.28" | PV, RHW-2 | UL Listed, UL 2556 VW-1 | Black | 0000000 | 0000 | 0000 |