About Timer Relays
More
Choosing an Electrical Switch
More
Solid State Surface-Mount Timer Relays
Attach these relays to a flat surface using the mounting hole. They have no moving parts, so compared to mechanical switches, they require less maintenance, last longer, and are quieter.
Switches with a potentiometer (variable switch) allow you to adjust the delay within the range.
For technical drawings and 3-D models, click on a part number.
Timing Range | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | Switching Current @ Voltage | Ht. | Wd. | Dp. | Features | Each | |
Delayed Start (Delay-on-Make) | |||||||||||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | |||||||||||
2 | 24-240V AC/24-240V DC | 10 | 1 | 1 sec.-1,023 sec. | 1 A @ 120 V AC | 2" | 2" | 0.89" | Potentiometer | 00000000 | 0000000 |
Timer Relays
Turn machinery, such as paint and conveyor lines, on and off after a set period of time. These timer relays plug into relay sockets (sold separately) for fast installation and replacement.
Relay sockets mount on 35 mm DIN rail (also known as DIN 3) or flat surfaces.
For technical drawings and 3-D models, click on a part number.
Timer Relays | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Switching Current | Relay Sockets | |||||||||||
Number of Terminals | Input Voltage | Control Current, mA | No. of | Overall | @ 240V AC | @ 24V DC | Max. Switching Voltage | hp @ Switching Voltage | Timing Adjustment Style | Each | Each | ||
Interval | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 0000000 | 0000000 | 00000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
Switch-On (Single-Shot) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
Delayed Switch-Off (Delay-on-Break) | |||||||||||||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC | 1/3 hp @ 120 V AC, 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 00000 | 0000000 | 0000 |
Repeat Cycle | |||||||||||||
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | |||||||||||||
8 | 24V AC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 120V AC | 27 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 240V AC | 14 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 12V DC | 271 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
8 | 24V DC | 135 | 1 | 1 sec.-1,023 sec. | 10A | 10A | 240V AC/30V DC | 1/3 hp @ 240 V AC | DIP Switches | 00000000 | 000000 | 0000000 | 0000 |
Solid State DIN-Rail Mount Multifunction Interface Timer Relays
Considered solid state because they don’t have any moving parts, these timer relays last longer, switch faster, and are quieter than mechanical relays. They interface between your controller and components to isolate input and output circuits, preventing damage to your components from voltage spikes, amplifying the relay's signal, and reducing signal interference. Use these relays with switching applications, such as small motors and pilot lights. They offer multiple timing functions in one relay. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. Relays disconnect from the socket for easy replacement.
Relays with Relay Sockets | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Replacement Relays | |||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open)—SPST-NO | ||||||||||||||
5 | 24V AC, 24V DC | 12 | Delayed Start (Delay-on-Make) Interval Repeat Cycle | 4 | 0.1 sec.-6 hrs. | 2 A @ 240 V AC | 275V AC | 3 1/2" | 0.2" | 2.8" | 0000000 | 000000 | 0000000 | 000000 |
5 | 24V AC, 24V DC | 12 | Delayed Start (Delay-on-Make) Interval Repeat Cycle | 4 | 0.1 sec.-6 hrs. | 6 A @ 24 V DC | 33V DC | 3 1/2" | 0.2" | 2.8" | 0000000 | 00000 | 0000000 | 00000 |
DIN-Rail Mount Multifunction Interface Timer Relays
Protect components from voltage spikes while amplifying the relay’s signal and reducing interference for reliable transmission—these relays interface between your controller and system components to isolate the input and output circuits. They are often used for switching applications, such as small motors and pilot lights. These relays provide a variety of timing functions in one relay. The included relay socket mounts on 35 mm DIN rail (also known as DIN 3 rail) for fast installation. Relays disconnect from the socket for easy replacement.
Relays with Relay Sockets | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Timing Range | Replacement Relays | |||||||||||||
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | Overall | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
5 | 24V AC, 24V DC | 16 | Delayed Start (Delay-on-Make) Interval Repeat Cycle | 4 | 0.1 sec.-6 hrs. | 6A | 240V AC | 3 1/2" | 0.2" | 2.8" | 0000000 | 000000 | 0000000 | 00000 |
Solid State DIN-Rail Mount Multifunction Timer Relays
Quick-Disconnect
Terminals
For fast installation, mount these relays to 35 mm DIN rail (also known as DIN 3 rail). They also mount to flat surfaces. With no moving parts, these solid state relays last longer and require less maintenance, are quieter, and switch faster than mechanical relays. They provide a variety of timing functions in one relay.
Use relays with DIP switches for more precise control than knobs. They make it easier to set multiple relays to the same timing range.
Timing Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Control Current, mA | Timer Relay Function | No. of | O'all | Switching Current @ 240V AC | Max. Switching Voltage | Ht. | Wd. | Dp. | Wire Connection Type | Each | |
Relays with DIP Switches | |||||||||||||
1 Circuit Control with 1 Off (Normally Open)—SPST-NO | |||||||||||||
4 | 24V AC, 48V AC, 120V AC, 240V AC | 8 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 4 | 0.1 sec.-63 min. | 0.7A | 240V AC | 3" | 0.7" | 2.4" | Quick-Disconnect Terminals | 0000000 | 000000 |
4 | 9V DC, 12V DC, 24V DC, 48V DC, 60V DC, 110V DC | 8 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 4 | 0.1 sec.-63 min. | 0.7A | 240V AC | 3" | 0.7" | 2.4" | Quick-Disconnect Terminals | 0000000 | 00000 |
6 | 24V AC, 48V AC, 120V AC, 240V AC | 8 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 4 | 0.1 sec.-63 min. | 0.7A | 240V AC | 3" | 0.7" | 2.4" | Screw Terminals | 0000000 | 000000 |
6 | 9V DC, 12V DC, 24V DC, 48V DC, 60V DC, 110V DC | 8 | Delayed Start (Delay-on-Make) Interval Switch-On (Single-Shot) Delayed Switch-Off (Delay-on-Break) Repeat Cycle | 4 | 0.1 sec.-63 min. | 0.7A | 240V AC | 3" | 0.7" | 2.4" | Screw Terminals | 0000000 | 000000 |
DIP Switches
Configure instructions for electronic devices by sliding actuators to open or close each circuit. The actuators also make it easy to see your settings without turning on equipment. Since the contacts are gold plated, they have better conductivity and resist heat better than nickel-plated contacts. Push the contacts through holes in your circuit board, then solder them in place.
For technical drawings and 3-D models, click on a part number.
No. of Circuits Controlled | Switch Starting Position | No. of Terminals per Slide | Industry Designation | Switching Current @ Voltage | Max. Voltage | Actuator Material | Housing Material | Contact Material | Ht. | Wd. | Dp. | For Hole Ctr.-to-Ctr. | Pkg. Qty. | Pkg. | |
1 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.18" | 0.38" | 0.1" | 20 | 00000000 | 000000 |
2 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.28" | 0.38" | 0.1" | 20 | 00000000 | 00000 |
3 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.38" | 0.38" | 0.1" | 20 | 00000000 | 00000 |
4 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.48" | 0.38" | 0.1" | 20 | 00000000 | 00000 |
5 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.58" | 0.38" | 0.1" | 20 | 00000000 | 00000 |
6 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.68" | 0.38" | 0.1" | 20 | 00000000 | 00000 |
8 | 1 Off (Normally Open) | 2 | SPST-NO | 25 mA @ 25 V DC | 50V DC | White Plastic | Red Plastic | Gold-Plated Bronze | 0.3" | 0.88" | 0.38" | 0.1" | 20 | 00000000 | 00000 |
Remote Transmitters
Replace existing transmitters or team a transmitter and a receiver (not included) to remotely operate your automatic overhead door openers.
DIP-switch transmitters are compatible with Liftmaster openers that have a DIP-switch receiver. Use them to operate a single door. The three-button model has open, close, and stop functions.
No. of | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Transmitter/Receiver Type | Manufacturer Series | Devices Operated | Buttons | DIP Switches | Lg. | Wd. | Dp. | Batteries Included | Features | Each | |
DIP Switch | Liftmaster 811LMX | 1 | 1 | 12 | 3 1/8" | 1 3/4" | 3/4" | Yes | Visor Clip | 0000000 | 000000 |
DIP Switch | Liftmaster 813LMX | 1 | 3 | 12 | 3 1/8" | 1 3/4" | 3/4" | Yes | Visor Clip | 0000000 | 00000 |
Receiver (Liftmaster 850LM) | 0000000 | Each | 000000 |