About Pressure Transmitters
More
Differential Pressure Transmitters with Dial Indicator for Liquids
- For Use With: Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: ±2%
- Pipe Connection: NPT Female
- Housing Material: Brass
- Connection Material: Brass
- Temperature Range: -20° to 200° F
View readings at the source with the dial indicator or remotely using a receiver—these transmitters measure the difference in pressure between two inputs in liquid applications. The dial indicator operates independently of the transmitter and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. You’ll sometimes see them used to indicate a filter is clogged in a pump or cooling system. Rated NEMA 4X, these transmitters protect against dirt, washdown, and corrosion. They are also rated IP65 for protection from dust and rinsing. All are CSA certified, so they meet Canadian safety standards.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
For technical drawings and 3-D models, click on a part number.
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA, 0-5V DC Output Signal—Screw Terminals | |||||||||||
0-25 in. of H2O | 1,500 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2" | 4 7/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 0000000 |
0-1 psi | 1,500 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2" | 4 7/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-5 psi | 1,500 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2" | 4 7/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-15 psi | 5,000 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2 5/8" | 2 15/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-30 psi | 5,000 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2 5/8" | 2 15/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |
0-50 psi | 5,000 | 9-35V DC | 1/4 | No | 3/16" | 2 | 2 5/8" | 2 15/16" | IP65; NEC Class I Division 2 Groups A, B, C, D; NEC Class II Divisions 1, 2 Groups F, G; NEMA 4X | 0000000 | 000000 |