Extended-Life Plastic Circulation Pumps for Chemicals
These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Maintenance Kits | Replacement Impellers | |||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Intake (Gender) | Discharge (Gender) | Lg. | Wd. | Ht. | Each | Each | Each | |||
120V AC, 240V AC, Single Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
23 | __ | 20 | 10 | __ | __ | __ | 35 | __ | 1/4 | 2.07/4.14 | 1 (Female) | 1 (Female) | 14 3/8" | 5 1/8" | 7 7/8" | 0000000 | 000000000 | 00000000 | 000000 | 00000000 | 0000000 |
26 | __ | 26 | 12 | __ | __ | __ | 35 | __ | 1/3 | 3.24/6.84 | 1 (Female) | 1 (Female) | 16 5/16" | 6 1/8" | 8 3/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
57 | 57 | 53 | 30 | 25 | __ | __ | 45 | __ | 1/2 | 1.1/2.2 | 1 1/2 (Female) | 1 1/2 (Female) | 18 3/8" | 8 7/8" | 11 5/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
90 | 90 | 84 | 74 | 61 | 49 | __ | 70 | __ | 1 | 1.5/3 | 1 1/2 (Female) | 1 1/2 (Female) | 18 7/8" | 6 5/16" | 10 1/8" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
120V AC, 208–240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 7.5/3.7-3.7 | 1 (Female) | 3/4 (Male) | 15 1/2" | 9" | 8 1/4" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 9.2/6.3-4.6 | 1 1/2 (Female) | 1 (Male) | 17 13/16" | 9 1/8" | 8 3/16" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
208–240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | |||||||||||||||||||||
Hardwire | |||||||||||||||||||||
30 | 31 | 26 | 20 | 7 | __ | __ | 41 | 5 | 1/3 | 0.6/1.3-1.2 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/4" | 7 3/8" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 1.7/1.7-0.8 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/8" | 7 3/16" | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 1.1/3.3-2.2 | 1 1/2 (Female) | 1 (Male) | 16 9/16" | 9 1/8" | 7 3/8" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
82 | 82 | 82 | 81 | 80 | 71 | 61 | 85 | 5 | 2 | 2.4/4.9-4.8 | 2 (Male) | 1 1/2 (Male) | 20 11/16" | 10 3/8" | 10" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
120 | 120 | 120 | 120 | 112 | 105 | 92 | 95 | 5 | 3 | 3.9/8-7.8 | 2 (Male) | 1 1/2 (Male) | 24 3/8" | 11 1/2" | 10 1/2" | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
Circulation Pumps for Fuel and Flammable Liquid
Pump fuel and flammable liquids, such as isopropyl alcohol and xylene. These pumps have an explosion-proof motor that is rated for environments where hazardous material is present. Maximum temperature is 250° F or the boiling point of the liquid being pumped, whichever is lower. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
For technical drawings and 3-D models, click on a part number.
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 7.4/3.7 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
25 | 31 | 25 | 13 | 1 | 62 | 150 | 264 | 1/2 | 2.4-2.2/1.1 | 3/4 | 1/2 | 15 5/8" | 10 7/8" | 7 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
100 | __ | 78 | 48 | 10 | 64 | 150 | 264 | 1 | 2.8/1.4 | 1 1/2 | 1 | 15 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Pumps | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Replacement Impellers | |||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 60 ft. of Head, gpm | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Intake (Female, NPT) | Discharge (Female, NPT) | Lg. | Wd. | Ht. | Each | Each | ||
120/208-240V AC, Single Phase—Hardwire | ||||||||||||||||||
15 | __ | 10 | 4 | __ | 46 | 150 | 264 | 1/3 | 4.8/2.4 | 3/4 | 1/2 | 15 1/2" | 10 7/8" | 7 1/2" | 0000000 | 000000000 | 00000000 | 0000000 |
100 | 78 | 64 | 48 | 10 | 64 | 150 | 264 | 1 | 12/6 | 1 1/2 | 1 | 17 1/4" | 10 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
208-240/460V AC, Three Phase—Hardwire | ||||||||||||||||||
115 | __ | 100 | 90 | 60 | 81 | 150 | 264 | 1 1/2 | 5-4.6/2.3 | 1 1/2 | 1 | 16 3/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
125 | 114 | 98 | 78 | 18 | 69 | 150 | 264 | 2 | 5.7-5.4/2.7 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
140 | __ | __ | 120 | 47 | 75 | 150 | 264 | 3 | 8.1-7.6/3.8 | 2 | 1 1/2 | 17 1/8" | 11 7/8" | 8 1/2" | 0000000 | 00000000 | 00000000 | 000000 |
Maintenance Kit | 00000000 | Each | 0000000 |
Self-Priming Circulation Pumps without Motor for Oil
Use these pumps to move lubricating oil such as hydraulic and motor oil. Also known as flexible impeller pumps, they create a suction force that can draw liquid upward to fill the pump chamber when your liquid source is below the pump. The impeller resists clogging and wear. Select a spark-free air motor for hazardous environments or attach an electric motor with a speed reducer or a belt pulley to alter the pump speed.
Repair kits (sold separately) include components such as impellers, O-rings, and seal lips.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry.
For technical drawings and 3-D models, click on a part number.
Intake (NPT) | Discharge (NPT) | Shaft | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | Max. Ft. of Head, ft. | Max. Pressure, psi | Max. Viscosity | Temp. Range, °F | Required hp | Gender | Pipe Size | Gender | Pipe Size | Dia. | Lg. | Ctr.-to-Base Lg. | Ht. | Lg. | Wd. | Each | |
For 500 rpm-2,100 rpm Motor Speed | |||||||||||||||||
11.5 | 50 | 21 | Not Rated | 50° to 180° | 1/3 hp | Female | 1/2 | Female | 1/2 | 5/8" | 1 1/8" | 1 15/16" | 3 13/16" | 4 1/2" | 4 1/8" | 0000000 | 0000000 |
25 | 50 | 26 | Not Rated | 50° to 180° | 3/4 hp | Female | 1 | Female | 1 | 5/8" | 2 1/4" | 1 7/8" | 3 9/16" | 6 3/8" | 4 3/4" | 0000000 | 000000 |