About Selecting Temperature Sensors
More
Cut-to-Length RTD Probes for Liquids and Gases
For a perfect fit in a thermowell, trim these probes with a pipe cutter. Stainless steel protects the sensing element from impact and liquids when they’re immersed. They are often installed in a bore to measure the temperature of molds, dies, and other equipment.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, ° F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 400° | 72" | 1/4" | 68 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 400° | 96" | 1/4" | 92 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 3/16" | 8 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 3/16" | 20 1/2" | ±0.12% | 2 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 000000000 | 000000 |
100 ohms | -55° to 900° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
100 ohms | -55° to 900° | 48" | 1/4" | 44 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 3 | 00000000 | 000000 |
Dual-Output Cut-to-Length RTD Probes for Liquids and Gases
Output temperature readings to two devices, or take an average temperature reading from two separate locations. To get a perfect fit in a thermowell or to replace an existing RTD probe, trim these probes to the exact length you need using a pipe cutter. Encased in metal, these probes are protected from damage and are safe to immerse in liquids. They’re also often installed in a bore to measure the temperature of molds, dies, and equipment.
Probe | Wire | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
RTD Type | Temperature Range, °F | Lg. | Dia. | Cuttable Lg. | Accuracy | Response Time, sec. | Connection Type | Sensing Tip Lg. | Sensing Element Material | Lead Lg. | Gauge | No. of Wires | Each | |
304 Stainless Steel Probe | ||||||||||||||
100 ohms | -55° to 400° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 0000000 |
100 ohms | -55° to 400° | 24" | 1/4" | 20 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |
100 ohms | -55° to 900° | 12" | 1/4" | 8 1/2" | ±0.12% | 4.4 | Wire Leads | 3" | Platinum | 6" | 24 | 6 | 000000000 | 000000 |