About Flowmeters and Totalizers
Flowmeters measure the rate of flow for a liquid or a gas. Totalizers measure the cumulative flow volume. Flowmeter/totalizers display both the flow rate and the cumulative flow volume.
More
DIN-Panel-Mount Electrically Actuated Counters
For quick installation, these counters fit standard DIN panel cutouts. Wire them up to an electrical pulse-emitting switch, sensor, or encoder for use on machine tools, packaging machinery, or other equipment.
Screw-on counters are rated NEMA 4X, NEMA 12, and IP65 for protection against dust, water, and splashing oil and coolant.
Counters with backlit display have good visibility in low-light conditions.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Max. Counts per Minute | DIN Size | Ht. | Wd. | Overall Dp. | Input Voltage | Features | Environmental Rating | Each | |
Screw On | ||||||||||||
Screw Terminals | ||||||||||||
Yes | Up or Down | 8 | 600 | 1/32 | 0.87" | 1.77" | 2.1" | 10-240V AC (High Level) 10-110V DC (Low Level) | Backlit Display, Battery-Powered Display | NEMA 4X, NEMA 12, IP65 | 0000000 | 000000 |
Yes | Up or Down | 8 | 600,000 | 1/32 | 0.87" | 1.77" | 2.1" | 18V DC | Backlit Display, Battery-Powered Display | NEMA 4X, NEMA 12, IP65 | 0000000 | 00000 |
Counters with Proximity Sensor
Count metallic objects as they touch or pass within 0.059" of this counter's built-in sensor. It has an output relay to send a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm. A scaling function lets you adjust the unit of measure to suit your application. Counter and enclosure are protected from dust and washdowns and can be used outdoors (rated NEMA 4X). Drill through the back of the enclosure to mount to a wall or work surface.
Sensor | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | No. of Set Points | Max. Counts per Minute | Max. Sensing Distance | Lg. | Dia. | Cord Lg., ft. | Ht. | Wd. | Dp. | Operating Voltage | Output Relay Current | Environmental Rating | Each | |
Screw On | ||||||||||||||||
Yes | Up or Down | 6 | 2 | 300,000 | 0.059" | 3 1/2" | 3/4" | 10 | 7.5" | 7.5" | 5.1" | 85-250V AC | 5 A @ 120 V AC 5 A @ 240 V AC 5 A @ 28 V DC | NEMA 4X | 00000000 | 000000000 |
Combination Switch-Contact/Electrically Actuated Counters with Output Relay
You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. An output relay sends a signal to another device when the counter reaches a set point. The signal can start/stop a process or trigger an alarm. If power is lost, count backup maintains the count and programming backup maintains settings. A scaling function lets you adjust the unit of measure to suit your application.
Counter rated NEMA 4X is protected from dust and washdowns and can be used outdoors.
Resettable | Counting Direction | No. of Digits | No. of Set Points | Max. Counts per Minute (Input Type) | Overall Dp. | Input Voltage | Operating Voltage | Output Relay Current | Includes | Features | Environmental Rating | Specifications Met | Each | |
Style B—For 1/16 DIN Panel Cutout (1.77" Ht. × 1.77" Wd.) | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Screw On | ||||||||||||||
Yes | Up and Down | 6 | 2 | 690,000 (Voltage), 690,000 (Switch Contact) | 4.2" | 0-30V DC | 11-14V DC 85-250V AC | 5 A @ 250 V AC | Gasket | Count Backup, Programming Backup, Scaling Function | IP65, NEMA 4X | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 |
Large-Display Combination Switch-Contact/Electrically
Actuated Counters with Output Relay
The digits displayed on these counters are visible up to 100 ft. away and the display can be adjusted to suit lighting conditions. You can set counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. They can be wired for remote reset. An output relay sends a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X). Programming backup maintains settings if power is lost.
Overall | Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | No. of Set Points | Max. Counts per Minute (Input Type) | Digit Ht. | Ht. | Wd. | Dp. | Input Voltage | Operating Voltage | Output Relay Current | Screw Size | Environmental Rating | Each | |
Screw On | |||||||||||||||
Screw Terminals | |||||||||||||||
Yes | Up or Down | 6 | 1 | 1,500,000 (Voltage), 3,000 (Switch Contact) | 2 1/4" | 4" | 16" | 2.25" | 2.75-28V DC | 21.6-250V DC 50-250V AC | 5 A @ 120 V AC 5 A @ 240 V AC 5 A @ 28 V DC | No. 10 | NEMA 4X | 00000000 | 000000000 |
Yes | Up or Down | 6 | 1 | 1,500,000 (Voltage), 3,000 (Switch Contact) | 4" | 7.875" | 26" | 2.25" | 2.75-28V DC | 21.6-250V DC 50-250V AC | 5 A @ 120 V AC 5 A @ 240 V AC 5 A @ 28 V DC | No. 10 | NEMA 4X | 00000000 | 00000000 |
Combination Switch-Contact/Electrically Actuated Counters
You can set these counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Count backup maintains the count if power is lost. A scaling function lets you adjust the unit of measure to suit your application.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Max. Counts per Minute (Input Type) | DIN Size | Ht. | Wd. | Overall Dp. | Input Voltage | Operating Voltage | Features | Environmental Rating | Specifications Met | Each | ||
Screw On | |||||||||||||||
Screw Terminals | |||||||||||||||
A | Yes | Up | 6 | 600,000 (Voltage), 600,000 (Switch Contact) | 1/32 | 0.87" | 1.77" | 2.4" | 4-30V DC (High Level), 0-1V DC (Low Level) | 10-30V DC | Count Backup | IP65 NEMA 4X | CE Marked | 0000000 | 0000000 |
A | Yes | Up and Down | 6 | 600,000 (Voltage), 600,000 (Switch Contact) | 1/32 | 0.87" | 1.77" | 2.4" | 4-30V DC (High Level), 0-1V DC (Low Level) | 10-30V DC | Count Backup, Scaling Function | IP65 NEMA 4X | CE Marked | 0000000 | 000000 |
Large-Display Combination Switch-Contact/Electrically Actuated Counters
The digits displayed on these counters are visible up to 100 ft. away and the display can be adjusted to suit lighting conditions. You can set counters up to count with or without voltage inputs based on the switch, sensor, or encoder you have. Counters can be wired for remote reset. They are protected against dust and washdowns and can be used outdoors (rated NEMA 4X). Programming backup maintains settings if power is lost.
Overall | Mounting | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Max. Counts per Minute (Input Type) | Digit Ht. | Ht. | Wd. | Dp. | Input Voltage | Operating Voltage | Screw Size | Environmental Rating | Each | |
Screw On | |||||||||||||
Screw Terminals | |||||||||||||
Yes | Up or Down | 4 | 3,000 (Switch Contact), 1,500,000 (Voltage) | 2 1/4" | 4" | 12" | 2.25" | 2.75-28V DC | 50-250V AC, 21.6-250V DC | No. 10 | NEMA 4X | 00000000 | 0000000 |
Yes | Up or Down | 4 | 3,000 (Switch Contact), 1,500,000 (Voltage) | 4" | 7.875" | 20" | 2.25" | 2.75-28V DC | 50-250V AC, 21.6-250V DC | No. 10 | NEMA 4X | 00000000 | 00000000 |
Yes | Up or Down | 6 | 3,000 (Switch Contact), 1,500,000 (Voltage) | 2 1/4" | 4" | 16" | 2.25" | 2.75-28V DC | 50-250V AC, 21.6-250V DC | No. 10 | NEMA 4X | 00000000 | 000000 |
Yes | Up or Down | 6 | 3,000 (Switch Contact), 1,500,000 (Voltage) | 4" | 7.875" | 26" | 2.25" | 2.75-28V DC | 50-250V AC, 21.6-250V DC | No. 10 | NEMA 4X | 00000000 | 00000000 |
Counters/Ratemeters
Wire these counters/ratemeters to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. A scaling function lets you adjust the unit of measure to suit your application. Use the toggle button to switch between the count and the rate. IP or NEMA rated, they protect against dust and washdowns and can be used outdoors.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Max. Counts per Minute (Input Type) | Ht. | Wd. | Ht. | Wd. | Dp. | Input Voltage | Features | Environmental Rating | Specifications Met | Each | |
Clip On | ||||||||||||||
Screw Terminals | ||||||||||||||
Yes | Up and Down | 8 | 960,000 (Voltage), 3,000 (Switch Contact) | 1.29" | 2.62" | 1.54" | 2.95" | 1.86" | 1.25-28V DC (High Level), 2.75-28V DC (Low Level) | Quadrature Sensing, Scaling Function, Toggle Button | IP65, NEMA 4X | CE Marked, C-UL Listed, UL Listed | 0000000 | 0000000 |
DIN-Panel-Mount Counters/Ratemeters
For quick installation, these counters/ratemeters fit a standard 1/8 DIN panel cutout. Wire them up to an electrical pulse-emitting switch, sensor, or encoder to count input while tracking rates in units such as gallons per minute. The scaling function lets you adjust the unit of measure to suit your application. Counters are protected from dust and washdowns and can be used outdoors (rated NEMA 4X).
Optional output relays send a signal to another device when a set point is reached. The signal can start/stop a process or trigger an alarm.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Max. Counts per Minute (Input Type) | DIN Size | Ht. | Wd. | Ht. | Wd. | Dp. | Input Voltage | Operating Voltage | Includes | Environmental Rating | Specifications Met | Each | |
Screw On | ||||||||||||||||
Screw Terminals | ||||||||||||||||
Yes | Up and Down | 6 | 2,000,000 (Voltage), 2,000,000 (Switch Contact) | 1/8 | 1.77" | 3.62" | 2" | 3.8" | 4.2" | 0-30V DC | 85-250V AC | 12V DC Power Source for External Sensor | IP65, NEMA 4X | CE Marked, UL Listed, C-UL Listed | 0000000 | 0000000 |
Yes | Up and Down | 6 | 2,000,000 (Voltage), 2,000,000 (Switch Contact) | 1/8 | 1.77" | 3.62" | 2" | 3.8" | 4.2" | 0-30V DC | 11-36V DC | 12V DC Power Source for External Sensor | IP65, NEMA 4X | CE Marked, UL Listed, C-UL Listed | 0000000 | 000000 |
Large-Display Counters/Ratemeters with Output Relay
At a glance, quickly read counts and rates in units, such as gallons per minute. The display on these counters/ratemeters is visible up to 130 ft. away—almost half of a football field—and gets brighter or dimmer based on your lighting. They have an output relay, so you can program them to start or stop a process or trigger an alarm when they reach their setpoint. These counters/ratemeters count using either a voltage or switch contact input, so they work with most sensors, encoders, and switches. You can wire them to reset remotely.
Press the button on the display to toggle between the count and rate. You can also program these counters/ratemeters to toggle automatically between the count and rate every few seconds. With the scaling function, you can change the unit of measure. Hardwire them to power the display. They have a programming backup, so if you lose power you won't lose your settings.
IP65 and NEMA 4X rated, these counters/ratemeters stand up to dust, rain, snow, and washdowns.
For technical drawings and 3-D models, click on a part number.
Overall | Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Max. Counts per Minute (Input Type) | Ht. | Wd. | Dp. | Input Voltage | Output Relay Current | Fasteners Included | Screw Size | Environmental Rating | Specifications Met | Each | |
Screw On | ||||||||||||||
Screw Terminals | ||||||||||||||
Yes | Up and Down | 6 | 1,500,000 (Voltage), 1,500,000 (Switch Contact) | 4" | 16" | 2.25" | 28V DC | 5 A @ 120 V AC 5 A @ 28 V DC | No | No. 10 | IP65, NEMA 4X | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000000 |
Yes | Up and Down | 6 | 1,500,000 (Voltage), 1,500,000 (Switch Contact) | 7.875" | 26" | 2.25" | 28V DC | 5 A @ 120 V AC 5 A @ 28 V DC | No | No. 10 | IP65, NEMA 4X | UL Listed, C-UL Listed, CE Marked | 0000000 | 00000000 |
Panel-Mount Electrically Actuated Hour Meters
Display running time on a machine so you can schedule preventative maintenance.
Non-resettable meters prevent tampering and accidental loss of data.
Meters that are rated NEMA 4X are protected from dust and washdowns and can be used outdoors.
Switch-Contact-Actuated Hour Meters
No need for a separate power source—these hour meters are powered by internal batteries that last more than 10 years. Often used where power sources aren’t easily accessible, they work well in remote monitoring systems, industrial equipment, and machinery. Wire the hour meter to a relay or switch on your machine so it can receive signals when the machine is running. The total number of hours is shown on the display. Press a button on the meter to reset the time to zero or connect it to a switch or button to reset it from a distance. These meters are UL recognized, C-UL recognized, and CE marked, so they meet American, Canadian, and European safety standards.
Screw on hour meters are IP65, NEMA 4X, and NEMA 12 rated, so they’re protected from dust, water, and splashing oil and coolant.
For Panel Cutout | Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Resettable | Counting Direction | No. of Digits | Ht. | Wd. | Ht. | Wd. | Dp. | Features | Environmental Rating | Specifications Met | Each | |
Screw On | ||||||||||||
Screw Terminals | ||||||||||||
Yes | Up and Down | 8 | 0.9" | 1.8" | 1" | 1.9" | 2.1" | Battery-Powered Display, Manual Reset Button, Remote Reset | IP65, NEMA 4X, NEMA 12 | UL Recognized Component, C-UL Recognized Component, CE Marked | 00000000 | 000000 |
High-Temperature Totalizers with Digital Display
The digital display on these totalizers makes it easy to check the total amount of high-temperature liquid—up to 200° F—passing through your system. They measure flow volume by counting how many times their turbine turns as liquid passes through. To avoid clogging the turbine and other damage to these totalizers, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow accurately no matter the mounting orientation. Rated NEMA 4X and IP65, they seal out dust and protect against washdowns and corrosion.
These totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Max. Volume, gallons | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Total | Batch | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Batteries Included | Environmental Rating | Each | |
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||||
3/8 NPT Male | 0.8 to 8 | 4 3/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 0000000 |
1/2 NPT Male | 2 to 20 | 5 1/8" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
3/4 NPT Male | 3 to 30 | 5 1/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 NPT Male | 5 to 50 | 5 5/8" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 1/2 NPT Male | 6 to 60 | 6 1/2" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
2 NPT Male | 10 to 100 | 6 3/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
Socket-Connect Flowmeter/Totalizers with Remote Display
Often used in hard-to-access areas, these flowmeter/totalizers have a display that can be placed up to 25 feet from the sensor. Use them to measure the rate and volume of liquid flowing through your system. They measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. Batch totals are resettable but can be protected with a security code to prevent tampering. The reset function can also be disabled so that they operate as a cumulative totalizer. Cumulative totals cannot be reset. No matter the mounting orientation, they’ll measure flow correctly.
These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
For a complete unit, you’ll need a display, a sensor, and a tee fitting (all sold separately).
Displays are rated NEMA 4X and IP65 for protection against dust, weather, washdowns, and corrosion.
For technical drawings and 3-D models, click on a part number.
For Panel Cutout | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. Total Volume | Accuracy | Max. Pressure | Temperature Range, °F | DIN Trade Size | Ht., mm | Wd., mm | Dp., mm | Batteries Included | Environmental Rating | Each | |
9,999 gallons, 9,999 liters | ±0.5% | 180 psi @ 70° F | 33° to 149° | 1/4 | 96 | 96 | 41 | Yes | IP65, NEMA 4X | 00000000 | 0000000 |
Optional Surface-Mounting Bracket (Four 3/16" × 3/4" Mounting Slots) | 0000000 | Each | 000000 |
High-Temperature Flowmeter/Totalizers
With one meter, these flowmeter/totalizers measure the flow rate and total flow volume of high-temperature liquid up to 200° F. They count how many times their turbine turns as liquid passes through to measure flow. To avoid clogging the turbine and other damage to the sensor, use them only with clean, low-viscosity liquids. The batch total can be reset after each metering application. They come set for batch totalization, but you can disable the reset function to operate as a cumulative totalizer. They measure flow correctly no matter the mounting orientation.
These flowmeter/totalizers are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
Max. Volume, gallons | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Flow Range, gpm | End-to-End Lg. | Accuracy | Total | Batch | Max. Pressure | Temp. Range, °F | Seal Material | Mounting Orientation | Batteries Included | Environmental Rating | Each | |
Polypropylene Plastic Body with Polypropylene Plastic Fittings | |||||||||||||
3/8 NPT Male | 0.8 to 8 | 4 3/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 0000000 |
1/2 NPT Male | 2 to 20 | 5 1/8" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
3/4 NPT Male | 3 to 30 | 5 1/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 NPT Male | 5 to 50 | 5 5/8" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 1/2 NPT Male | 6 to 60 | 6 1/2" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
2 NPT Male | 10 to 100 | 6 3/4" | ±2% | 99,999.9 | 999,999 | 300 psi @ 70° F | 33° to 200° | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
High-Temperature Flowmeters with Digital Display
Check the flow rate of liquids up to 200° F from an easy-to-read digital display instead of a scale or dial. These flowmeters measure flow by counting how many times their turbine turns as liquid flows through. To avoid clogging the turbine and other damage to these flowmeters, use them only with clean, low-viscosity liquids. Mount them inline with your pipe system. Their fittings are polypropylene, which works with a wide range of chemicals. NEMA and IP rated, these flowmeters stand up to dust, weather, corrosion, and water from washdowns.
These flowmeters are calibrated with water but can be used with other liquids. If you’re using these with a liquid other than water, you’ll need to calculate the flow rate by multiplying the number shown on the scale by the specific-gravity conversion factor for your liquid.
Flow Range, gpm | End-to-End Lg. | Overall Ht. | Accuracy | Max. Pressure | Temp. Range, °F | Body Material | Seal Material | Mounting Orientation | Batteries Included | Environmental Rating | Each | |
Polypropylene Plastic Fittings | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
3/8 NPT Male Pipe Connection | ||||||||||||
0.4 to 4 | 4 3/4" | 5 3/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 0000000 |
0.8 to 8 | 4 3/4" | 5 3/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1/2 NPT Male Pipe Connection | ||||||||||||
2 to 20 | 5 1/8" | 5 3/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
3/4 NPT Male Pipe Connection | ||||||||||||
3 to 30 | 5 1/4" | 5 5/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 NPT Male Pipe Connection | ||||||||||||
5 to 50 | 5 5/8" | 5 5/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
1 1/2 NPT Male Pipe Connection | ||||||||||||
6 to 60 | 6 1/2" | 6 1/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |
2 NPT Male Pipe Connection | ||||||||||||
10 to 100 | 6 3/4" | 6 3/8" | ±2% | 300 psi @ 70° F | 33° to 200° | Polypropylene Plastic | Fluoroelastomer Rubber | Any | Yes | IP56, NEMA 4X | 0000000 | 000000 |