90° Elbow Aluminum Submersible Cord Grips
Stop cords from coming loose in wet environments while keeping them along the side of your enclosure in tight spaces. A 90° bend and strain relief prevent your cord from kinking and pulling out, prolonging the cord's life. Made of aluminum, these grips are lighter in weight than steel and brass grips, yet strong enough for demanding applications. Since they’re IP and NEMA rated, they seal out dust, oil, and water from weather, washdowns, and brief submersion to protect parts in your enclosure.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
1.25"-1.375" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.438"-1.562" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1.562"-1.688" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1.688"-1.8" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
90° Elbow Sure-Grip Aluminum Submersible Cord Grips
Create a tight grip on cords in wet environments while reducing stress from bending—the 90° angle of these cord grips routes cords to fit tight spaces in enclosures and panels. Made of aluminum, these grips are lighter than steel and brass, yet strong enough to withstand use in demanding environments. A wire mesh extension gives these cord grips extra hold and stability, which reduces the stress of bending and helps extend the lifespan of cords. They’re good for applications with a lot of movement, such as handheld equipment, moving machinery, and robotics. NEMA and IP rated, these cords withstand use under water and protect electronics inside enclosures from moisture, oil, and harsh chemicals.
For technical drawings and 3-D models, click on a part number.
Mesh | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Length | Material | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
1.25"-1.37" | 2 | 13 3/4" | Stainless Steel | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 0000000 |
1.44"-1.56" | 2 | 13 3/4" | Stainless Steel | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.56"-1.68" | 2 | 15" | Stainless Steel | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.69"-1.81" | 2 | 12 1/2" | Stainless Steel | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
Aluminum Submersible Cord Grips for Building Cable
With an oval bushing hole, these lightweight grips secure flat building cable, such as Romex and Festoon cable, in wet areas. All offer strain relief to extend cable life. Made of aluminum, these grips are lighter in weight than steel and brass grips yet durable. They are NEMA and IP rated, so they’ll stand up to dust, oil, washdowns, and temporary submersion in water.
For technical drawings and 3-D models, click on a part number.
For Cord | |||||||||
---|---|---|---|---|---|---|---|---|---|
Width | Thickness | For Knockout Trade Size | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Each | |
1.46" | 0.45" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 000000 |
1.5" | 0.47" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.63" | 0.99" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.65" | 0.22" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.71" | 0.5" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.75" | 0.63" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.77" | 0.24" | 2 | 2 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
Aluminum Cord Grips
These cord grips are lightweight yet durable. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid. The inner rings are colored by size so you can identify them at a glance.
Locknut and O-ring kits (sold separately) create liquid-tight seals between cord grips and enclosure knockouts. When used together with the cord grips, they meet NEMA 4X, NEMA 13, and IP66 ratings, so they can be used indoors and outdoors to protect against corrosion, dust, spraying water, oil, and coolant. Each kit includes two locknuts and one or two O-rings.
For technical drawings and 3-D models, click on a part number.
Cord Grips | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Knockout Connection | Each | Locknut and O-Ring Kits | |||||||||
For Cord OD | For Knockout Trade Size | Type | Gender | Temperature Range, °F | Environmental Rating | Specifications Met | 1-9 | 10-Up | Each | ||
NPT Threads | |||||||||||
1.25"-1.38" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 000000 | 00000000 | 00000 |
1.38"-1.5" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 00000000 | 0000 |
1.5"-1.63" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 00000000 | 0000 |
1.63"-1.75" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 00000000 | 0000 |
1.75"-1.88" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 00000000 | 0000 |
1.81"-1.94" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 00000 | 00000000 | 0000 |
1.94"-2.06" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 00000 | 00000000 | 0000 |
2.06"-2.19" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 00000 | 00000000 | 0000 |
2.19"-2.31" | 2 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 00000 | 00000000 | 0000 |
Sure-Grip Aluminum Cord Grips
A mesh extension provides a secure hold in applications where cable is pulled or in motion. It reduces stress on the cable and prevents kinking for longer cable life. A plastic bushing seals out dust and dirt.
For technical drawings and 3-D models, click on a part number.
Mesh | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Lg. | Material | Thread Type | Temperature Range, °F | Features | Specifications Met | Each | |
1.4"-1.75" | 2 | 14" | Steel | NPT | -40° to 220° | Zinc-Plated Steel Locknut | UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |
Screw-Down Cord Grips for Building Cable
Tighten the screws to secure building cable for dry locations, also known as Romex type NM-B cable, to enclosures and outlet boxes.
For technical drawings and 3-D models, click on a part number.
For Trade Size | Each | |||||||
---|---|---|---|---|---|---|---|---|
Max. Hole Dia. | Conduit | Knockout | Material | Features | Specifications Met | 1-19 | 20-Up | |
2.09" | 2 | 2 | Zinc | Zinc Locknut | UL Listed | 0000000 | 00000 | 00000 |
Submersible Break-Through Multi-Cord Grips
These grips have a thin, flexible seal that covers the holes until you push cords through. They prevent liquid from entering your connections—grips are rated IP68 for protection from continuous submersion.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Thread Type | Material | Seal Material | Temp. Range, °F | Features | Environmental Rating | Specifications Met | Each | |
For 12 Cords | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0.28"-0.35" | 2 | NPT | Black Nylon Plastic | Rubber | 0° to 210° | Steel Locknut | IP68, NEMA 6P | UL Listed, CSA Certified | 0000000 | 000000 |
For 19 Cords | ||||||||||
0.24"-0.3" | 2 | NPT | Black Nylon Plastic | Rubber | 0° to 210° | Steel Locknut | IP68, NEMA 6P | UL Listed, CSA Certified | 0000000 | 00000 |
For 31 Cords | ||||||||||
0.17"-0.22" | 2 | NPT | Black Nylon Plastic | Rubber | 0° to 210° | Steel Locknut | IP68, NEMA 6P | C-UL Recognized Component, UL Recognized Component | 0000000 | 00000 |
Multi-Cord Grips for Building Cable
Secure multiple flat cable through one cord grip—reducing the space and number you need for a project, as well as saving time. With oval bushing holes, these cord grips protect Romex, festoon, and other commonly used flat building cable against harmful elements. They also relieve the strain on a cable when it's pulled, extending the life of the cable.
NEMA and IP rated, these cords withstand use under water and protect electronics inside enclosures from moisture, oil, and harsh chemicals. All bushing holes must be used in order to create a protective seal.
For technical drawings and 3-D models, click on a part number.
For Cord | ||||||||
---|---|---|---|---|---|---|---|---|
Width | Thickness | For Knockout Trade Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Each | |
Aluminum | ||||||||
For 2 Cords | ||||||||
1.37" | 0.25" | 2 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 000000 |
1.5" 1.125" | 0.265" 0.469" | 2 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.65" | 0.22" | 2 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.75" 0.9" | 0.25" 0.3" | 2 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.77" | 0.24" | 2 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |