Compact Plastic Submersible Cord Grips
These grips are sized to fit in tight areas. They are rated IP68 and 69K for protection from continuous submersion and high-pressure, high-temperature jets of water. They are also rated NEMA 4X, 6, and 12 for indoor and outdoor protection against corrosion, water projected from a hose, and dripping oils and lubricants. A rubber bushing and O-ring create a tight seal to prevent liquid from entering the connection. For the strongest hold and most secure seal around a cord, select cord grips with the smallest cord OD range that will work with your cord.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Pipe Size | Material | Temp. Range, °F | Features | Environmental Rating | Specifications Met | Each | |
NPT Threads | |||||||||
---|---|---|---|---|---|---|---|---|---|
0.51"-0.79" | 1 1/4 | 1 1/4 | Black Nylon Plastic | -20° to 210° | Rubber O-Ring, Zinc-Plated Steel Locknut | IP68, IP69K, NEMA 4X, NEMA 6, NEMA 12 | UL Listed, CSA Certified, UL 746C f1, UL 94 V-0, CE Marked | 00000000 | 000000 |
0.71"-0.98" | 1 1/4 | 1 1/4 | Black Nylon Plastic | -20° to 210° | Rubber O-Ring, Zinc-Plated Steel Locknut | IP68, IP69K, NEMA 4X, NEMA 6, NEMA 12 | UL Listed, CSA Certified, UL 746C f1, UL 94 V-0, CE Marked | 00000000 | 00000 |
Wraparound Plastic Submersible Cord Grips
Wrap the split gland of these grips around ethernet cables with an RJ45 connector or other already installed cables for a water-resistant seal with your enclosure. They’re rated IP68 and NEMA 6P, so they withstand use under water and protect electronics inside enclosures from moisture and harsh chemicals. All are made of nylon, making them corrosion and wear resistant. They relieve the strain on a cable when its pulled, extending the life of the cable.
When choosing a size, keep in mind that the sealing nut ID and body ID must be large enough for the end of your cord to fit through with the connector.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Sealing Nut ID | Body ID | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
NPT Threads | |||||||||
---|---|---|---|---|---|---|---|---|---|
0.25"-0.33" | 1 1/4 | 1.27" | 1.25" | 0° to 210° | Nylon Plastic Locknut, Split Gland | IP68, NEMA 6P | UL Recognized Component, C-UL Recognized Component, UL 94 V-2 | 0000000 | 000000 |
Aluminum Submersible Cord Grips
Lighter in weight than steel and brass grips, these aluminum grips are strong enough to secure cords in demanding wet environments. All offer strain relief to extend cord life. They are NEMA and IP rated, so they’ll stand up to dust, oil, washdowns, and temporary submersion in water.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Pipe Size | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
NPT Threads | |||||||
---|---|---|---|---|---|---|---|
0.88"-1" | 1 1/4 | 1 1/4 | -40° to 250° | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 00000000 | 000000 |
1"-1.12" | 1 1/4 | 1 1/4 | -40° to 250° | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 00000000 | 00000 |
1.13"-1.25" | 1 1/4 | 1 1/4 | -40° to 250° | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 00000000 | 00000 |
90° Elbow Aluminum Submersible Cord Grips
Stop cords from coming loose in wet environments while keeping them along the side of your enclosure in tight spaces. A 90° bend and strain relief prevent your cord from kinking and pulling out, prolonging the cord's life. Made of aluminum, these grips are lighter in weight than steel and brass grips, yet strong enough for demanding applications. Since they’re IP and NEMA rated, they seal out dust, oil, and water from weather, washdowns, and brief submersion to protect parts in your enclosure.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
0.562"-0.688" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
0.688"-0.812" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
0.75"-0.875" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
0.875"-1" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1"-1.125" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1.125"-1.25" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1.25"-1.375" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
90° Elbow Sure-Grip Aluminum Submersible Cord Grips
Create a tight grip on cords in wet environments while reducing stress from bending—the 90° angle of these cord grips routes cords to fit tight spaces in enclosures and panels. Made of aluminum, these grips are lighter than steel and brass, yet strong enough to withstand use in demanding environments. A wire mesh extension gives these cord grips extra hold and stability, which reduces the stress of bending and helps extend the lifespan of cords. They’re good for applications with a lot of movement, such as handheld equipment, moving machinery, and robotics. NEMA and IP rated, these cords withstand use under water and protect electronics inside enclosures from moisture, oil, and harsh chemicals.
For technical drawings and 3-D models, click on a part number.
Mesh | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Length | Material | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
0.75"-0.87" | 1 1/4 | 10" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 0000000 |
0.88"-1" | 1 1/4 | 10" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1"-1.12" | 1 1/4 | 10" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.13"-1.25" | 1 1/4 | 10 1/2" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.25"-1.37" | 1 1/4 | 12" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
Aluminum Submersible Cord Grips for Building Cable
With an oval bushing hole, these lightweight grips secure flat building cable, such as Romex and Festoon cable, in wet areas. All offer strain relief to extend cable life. Made of aluminum, these grips are lighter in weight than steel and brass grips yet durable. They are NEMA and IP rated, so they’ll stand up to dust, oil, washdowns, and temporary submersion in water.
For technical drawings and 3-D models, click on a part number.
For Cord | |||||||||
---|---|---|---|---|---|---|---|---|---|
Width | Thickness | For Knockout Trade Size | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Each | |
1.13" | 0.22" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 000000 |
1.19" | 0.35" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.24" | 0.24" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
1.37" | 0.25" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 00000000 | 00000 |
45° Elbow Aluminum Submersible Cord Grips
Use these lightweight grips to secure cords entering knockouts at a 45° angle in wet, tight spaces while easing the stress from bending. Made of aluminum, they’re lighter in weight than steel and brass grips yet durable. All are NEMA and IP rated, so they’ll stand up to dust, oil, washdowns, and temporary submersion in water.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
0.57"-0.68" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
0.69"-0.81" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
0.75"-0.87" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
0.88"-1" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1"-1.12" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1.13"-1.25" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
1.25"-1.37" | 1 1/4 | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 00000 |
45° Elbow Sure-Grip Aluminum Submersible Cord Grips
Keep your cord at a gentle angle without sacrificing a tight hold, even in tough, wet environments. The 45° bend reduces bending stress and saves space around your enclosure. To strengthen their grip and stop kinks, these grips have a stainless steel mesh, making them best for cords on handheld equipment, robotics, and other moving machines. They're aluminum, which is lighter than steel and brass, yet strong enough for demanding applications. All are IP and NEMA rated, so they seal out dust, oil, and water from rain, washdowns, and brief submersion to protect parts in your enclosure.
For technical drawings and 3-D models, click on a part number.
Mesh | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Length | Material | Pipe Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | Each | |
0.75"-0.87" | 1 1/4 | 10 3/4" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 0000000 |
0.88"-1" | 1 1/4 | 10 3/4" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1"-1.12" | 1 1/4 | 10 3/4" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.13"-1.25" | 1 1/4 | 11 1/4" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
1.25"-1.37" | 1 1/4 | 10 3/4" | Stainless Steel | 1 1/4 | NPT | -40° to 250° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | UL Listed, CSA Certified | 0000000 | 000000 |
Aluminum Cord Grips
These cord grips are lightweight yet durable. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid. The inner rings are colored by size so you can identify them at a glance.
Locknut and O-ring kits (sold separately) create liquid-tight seals between cord grips and enclosure knockouts. When used together with the cord grips, they meet NEMA 4X, NEMA 13, and IP66 ratings, so they can be used indoors and outdoors to protect against corrosion, dust, spraying water, oil, and coolant. Each kit includes two locknuts and one or two O-rings.
For technical drawings and 3-D models, click on a part number.
Cord Grips | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Knockout Connection | Each | Locknut and O-Ring Kits | |||||||||
For Cord OD | For Knockout Trade Size | Type | Gender | Temperature Range, °F | Environmental Rating | Specifications Met | 1-9 | 10-Up | Each | ||
NPT Threads | |||||||||||
0.75"-0.88" | 1 1/4 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 000000 | 0000000 | 000000 |
0.88"-1" | 1 1/4 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 0000000 | 00000 |
1"-1.13" | 1 1/4 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 0000000 | 00000 |
1.13"-1.25" | 1 1/4 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 0000000 | 00000 |
1.25"-1.38" | 1 1/4 | Threaded | Male | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 0000000 | 00000 |
90° Elbow Aluminum Cord Grips
These cord grips are lightweight yet durable. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid. The inner rings are colored by size so you can identify them at a glance.
Locknut and O-ring kits (sold separately) create liquid-tight seals between cord grips and enclosure knockouts. When used together with the cord grips, they meet NEMA 4X, NEMA 13, and IP66 ratings, so they can be used indoors and outdoors to protect against corrosion, dust, spraying water, oil, and coolant. Each kit includes two locknuts and one or two O-rings.
For technical drawings and 3-D models, click on a part number.
Cord Grips | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Each | Locknut and O-Ring Kits | |||||||||
For Cord OD | For Knockout Trade Size | Thread Type | Temperature Range, °F | Environmental Rating | Specifications Met | 1-9 | 10-Up | Each | ||
0.88"-1" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 000000 | 0000000 | 000000 |
1"-1.13" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 0000000 | 00000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 | 0000000 | 00000 |
45° Elbow Aluminum Cord Grips
Secure and seal electrical cords entering knockouts at a 45° angle. As you tighten these grips, a nylon inner ring and lubricated rubber bushing secure the cords to keep them connected and prevent overtightening. They also create a seal around the cords to block out liquids. Made of aluminum, all of these grips are lighter in weight than steel grips yet durable.
Optional locknut and O-ring kits create liquid-tight seals between cord grips and enclosure knockouts. When used together with the cord grips, they meet NEMA 4X, NEMA 13, and IP66 ratings, so they can be used indoors and outdoors to protect against corrosion, dust, spraying water, oil, and coolant. Each kit includes two locknuts and one or two O-rings.
For technical drawings and 3-D models, click on a part number.
Cord Grips | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Each | Locknut and O-Ring Kits | |||||||||||
For Cord OD | For Knockout Trade Size | Pipe Size | Thread Type | Insert Color | Temperature Range, °F | Environmental Rating | Specifications Met | 1-9 | 10-Up | Each | ||
1"-1.13" | 1 1/4 | 1 1/4 | NPT | White | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 0000000 | 000000 |
1.13"-1.25" | 1 1/4 | 1 1/4 | NPT | White | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | 0000000 | 00000 |
Sure-Grip Aluminum Cord Grips
A mesh extension provides a secure hold in applications where cable is pulled or in motion. It reduces stress on the cable and prevents kinking for longer cable life. A plastic bushing seals out dust and dirt.
For technical drawings and 3-D models, click on a part number.
Mesh | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Lg. | Material | Thread Type | Temperature Range, °F | Features | Specifications Met | Each | |
0.94"-1.25" | 1 1/4 | 11" | Steel | NPT | -40° to 220° | Zinc-Plated Steel Locknut | UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |
Steel and Iron Cord Grips
Stronger than aluminum cord grips, these grips are zinc plated for corrosion resistance. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid.
Locknut and O-ring kits (sold separately) create liquid-tight seals between cord grips and enclosure knockouts. When used together with the cord grips, they meet NEMA 4X, NEMA 13, and IP66 ratings, so they can be used indoors and outdoors to protect against corrosion, dust, spraying water, oil, and coolant. Each kit includes two locknuts and two O-rings—enough to seal two cord grips.
For technical drawings and 3-D models, click on a part number.
Cord Grips | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Each | Locknut and O-Ring Kits | |||||||||
For Cord OD | For Knockout Trade Size | Thread Type | Temp. Range, °F | Environmental Rating | Specifications Met | 1-9 | 10-Up | Each | ||
Zinc-Plated Iron | ||||||||||
1"-1.13" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 | 0000000 | 000000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | 0000000 | 00000 |
1.25"-1.38" | 1 1/4 | NPT | -30° to 225° | NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 00000 | 00000 | 0000000 | 00000 |
Screw-Down Cord Grips for Building Cable
Tighten the screws to secure building cable for dry locations, also known as Romex type NM-B cable, to enclosures and outlet boxes.
For technical drawings and 3-D models, click on a part number.
For Trade Size | Each | |||||||
---|---|---|---|---|---|---|---|---|
Max. Hole Dia. | Conduit | Knockout | Material | Features | Specifications Met | 1-19 | 20-Up | |
1.41" | 1 1/4 | 1 1/4 | Zinc | Zinc Locknut | UL Listed | 0000000 | 00000 | 00000 |
Locking Snap-In Cord Grips for Building Cable
An insert clamps the cable in place and provides more strain relief than standard snap-in cord grips for building cable. Use to connect building cable for dry locations, also known as Romex type NM-B cable, to enclosures and outlet boxes by pushing these grips into a knockout.
For technical drawings and 3-D models, click on a part number.
For Trade Size | For Max. Cable | Each | ||||||
---|---|---|---|---|---|---|---|---|
Conduit | Knockout | Dia. | Material | Cord Holding Type | Specifications Met | 1-19 | 20-Up | |
1 1/4 | 1 1/4 | 1.44" | Gray PVC Plastic | Locking Tab | UL Listed, C-UL Listed, CSA Certified | 0000000 | 00000 | 00000 |
Aluminum Wet-Location Cord Grips
These cord grips are lightweight yet durable. They have a zinc-plated steel locknut and metal-reinforced rubber O-ring that prevents liquid from entering the connection. All are rated NEMA 4X, NEMA 13, and IP66 to provide indoor and outdoor protection against dust, corrosion, water projected from a hose, and oil/coolant spray.
Grips have a knurled collar for hand tightening. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid. The inner ring is colored by size, so you can identify the grips’ size at a glance.
For technical drawings and 3-D models, click on a part number.
Each | ||||||||
---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Thread Type | Temp. Range, °F | Features | Specifications Met | 1-9 | 10-Up | |
0.75"-0.88" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 000000 |
0.88"-1" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
1"-1.13" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
1.25"-1.38" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
90° Elbow Aluminum Wet-Location Cord Grips
These cord grips are lightweight yet durable. They have a zinc-plated steel locknut and metal-reinforced rubber O-ring that prevents liquid from entering the connection. All are rated NEMA 4X, NEMA 13, and IP66 to provide indoor and outdoor protection against dust, corrosion, water projected from a hose, and oil/coolant spray.
Grips have a knurled collar for hand tightening. As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid. The inner ring has an insert that is colored by size, so you can identify them at a glance.
For technical drawings and 3-D models, click on a part number.
Each | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Thread Type | Insert Material | Temp. Range, °F | Features | Environmental Rating | Specifications Met | 1-9 | 10-Up | |
0.88"-1" | 1 1/4 | NPT | White Nylon | -30° to 225° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 4X, NEMA 13, IP66, NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 000000 | 000000 |
1"-1.13" | 1 1/4 | NPT | White Nylon | -30° to 225° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 4X, NEMA 13, IP66, NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
1.13"-1.25" | 1 1/4 | NPT | White Nylon | -30° to 225° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 4X, NEMA 13, IP66, NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
1.25"-1.38" | 1 1/4 | NPT | White Nylon | -30° to 225° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 4X, NEMA 13, IP66, NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 00000000 | 00000 | 00000 |
45° Elbow Aluminum Wet-Location Cord Grips
Secure cords in wet and industrial environments with little room—these grips curve 45° to relieve bending stress. Made of aluminum, they’re lighter in weight than steel yet strong enough for harsh applications. All are NEMA and IP rated, so they stand up to weather, washdowns, dirt, dust, oil, and coolant.
A nylon insert and rubber bushing on these grips stop cords from coming loose and seal out liquid. They also prevent you from overtightening the grip and cutting into the cord’s sheath. A zinc-plated steel locknut and rubber O-ring keep water from seeping into your enclosure.
For technical drawings and 3-D models, click on a part number.
Each | |||||||||
---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Specifications Met | 1-9 | 10-Up | |
1"-1.13" | 1 1/4 | NPT | -30° to 225° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 4X; NEMA 13; IP66; NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 000000 | 000000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 4X; NEMA 13; IP66; NEC Class III Divisions 1, 2 | UL Listed, CSA Certified | 0000000 | 00000 | 00000 |
Steel and Iron Wet-Location Cord Grips
Stronger than aluminum cord grips, these grips are zinc plated for corrosion resistance. They have a zinc-plated steel locknut and metal-reinforced rubber O-ring that prevents liquid from entering the connection. All are rated NEMA 4X, NEMA 13, and IP66 to provide indoor and outdoor protection against dust, corrosion, water projected from a hose, and oil/coolant spray.
As you tighten the grip, a nylon inner ring and lubricated rubber bushing secure your cable, prevent overtightening, and create a seal around the cord to block out liquid.
For technical drawings and 3-D models, click on a part number.
Each | ||||||||
---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Thread Type | Temp. Range, °F | Features | Specifications Met | 1-9 | 10-Up | |
Zinc-Plated Iron | ||||||||
1"-1.13" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 0000000 | 000000 |
1.13"-1.25" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 00000 |
1.25"-1.38" | 1 1/4 | NPT | -30° to 225° | Nylon Plastic Inner Ring, Rubber O-Ring, Zinc-Plated Steel Locknut | UL Listed, CSA Certified | 00000000 | 000000 | 00000 |
Sure-Grip Hazardous Location Cord Grips
These grips meet Class III, Divisions 1 and 2 standards for use in hazardous locations. They have a mesh extension for a secure hold in applications where cable is pulled or in motion. It reduces stress on the cable and prevents kinking for longer cable life.
For technical drawings and 3-D models, click on a part number.
Mesh | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Lg. | Material | Thread Type | Material | Cord Holding Type | Bushing Material | Temp. Range, °F | Features | Environmental Rating | Each | |
1"-1.13" | 1 1/4 | 5 3/4" | Stainless Steel | NPT | Aluminum | Bushing | Rubber | -30° to 240° | Rubber O-Ring, Zinc-Plated Steel Locknut | IP66; NEC Class III Divisions 1, 2 | 0000000 | 0000000 |
90° Elbow Sure-Grip Hazardous Location Cord Grips
These grips meet Class III, Divisions 1 and 2 standards for use in hazardous locations. They have a mesh extension for a secure hold in applications where cable is pulled or in motion. It reduces stress on the cable and prevents kinking for longer cable life.
For technical drawings and 3-D models, click on a part number.
Mesh | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Lg. | Material | Thread Type | Material | Cord Holding Type | Bushing Material | Temp. Range, °F | Features | Environmental Rating | Each | |
1"-1.13" | 1 1/4 | 5 3/4" | Stainless Steel | NPT | Aluminum | Bushing | Rubber | -30° to 240° | Rubber O-Ring, Zinc-Plated Steel Locknut | IP66; NEC Class III Divisions 1, 2 | 0000000 | 0000000 |
Wet-Location Multi-Cord Grips
Grips have a rubber inner grommet with multiple holes and a rubber O-ring that create a tight seal to prevent liquid from entering the connection. They are rated IP65 for protection from water projected from a nozzle and NEMA 4X for indoor and outdoor protection against corrosion and water projected from a hose.
Nylon is chemical resistant.
For technical drawings and 3-D models, click on a part number.
Black Nylon Plastic | |||||||
---|---|---|---|---|---|---|---|
For Cord OD | For Knockout Trade Size | Thread Type | Temp. Range, °F | Features | Specifications Met | Each | |
For 6 Cords | |||||||
0.22"-0.26" | 1 1/4 | NPT | -40° to 210° | Rubber O-Ring, Zinc-Plated Steel Locknut | UL Recognized Component, CSA Certified | 0000000 | 000000 |
Submersible Break-Through Multi-Cord Grips
These grips have a thin, flexible seal that covers the holes until you push cords through. They prevent liquid from entering your connections—grips are rated IP68 for protection from continuous submersion.
For technical drawings and 3-D models, click on a part number.
For Cord OD | For Knockout Trade Size | Thread Type | Material | Seal Material | Temp. Range, °F | Features | Environmental Rating | Specifications Met | Each | |
For 7 Cords | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0.28"-0.35" | 1 1/4 | NPT | Black Nylon Plastic | Rubber | 0° to 210° | Steel Locknut | IP68, NEMA 6P | UL Listed, CSA Certified | 0000000 | 000000 |
For 9 Cords | ||||||||||
0.24"-0.3" | 1 1/4 | NPT | Black Nylon Plastic | Rubber | 0° to 210° | Steel Locknut | IP68, NEMA 6P | UL Listed, CSA Certified | 0000000 | 00000 |
For 13 Cords | ||||||||||
0.17"-0.22" | 1 1/4 | NPT | Black Nylon Plastic | Rubber | 0° to 210° | Steel Locknut | IP68, NEMA 6P | C-UL Recognized Component, UL Recognized Component | 0000000 | 00000 |
Multi-Cord Grips for Building Cable
Secure multiple flat cable through one cord grip—reducing the space and number you need for a project, as well as saving time. With oval bushing holes, these cord grips protect Romex, festoon, and other commonly used flat building cable against harmful elements. They also relieve the strain on a cable when it's pulled, extending the life of the cable.
NEMA and IP rated, these cords withstand use under water and protect electronics inside enclosures from moisture, oil, and harsh chemicals. All bushing holes must be used in order to create a protective seal.
For technical drawings and 3-D models, click on a part number.
For Cord | ||||||||
---|---|---|---|---|---|---|---|---|
Width | Thickness | For Knockout Trade Size | Thread Type | Temperature Range, °F | Features | Environmental Rating | Each | |
Aluminum | ||||||||
For 2 Cords | ||||||||
1.13" | 0.22" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 000000 |
1.13" 0.66" | 0.22" 0.24" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.13" 0.75" | 0.22" 0.25" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.13" 0.89" | 0.22" 0.29" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.24" | 0.24" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.24" 0.66" | 0.22" 0.24" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.24" 0.75" | 0.22" 0.25" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |
1.24" 0.89" | 0.24" 0.29" | 1 1/4 | NPT | -40° to 300° | Rubber O-Ring, Zinc-Plated Steel Locknut | NEMA 6, NEMA 12, IP65, IP67 | 0000000 | 00000 |