About AC to AC Voltage Transformers
For single-phase equipment, use this formula to find power output: VA = Volts × Amps
For three-phase equipment, use this formula to find power output: VA = Volts × Amps × 1.73
More
High-Inrush Panel-Mount AC to AC Transformers
These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.
Voltage | ||||||||
---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Specifications Met | Each | |
Step Down Voltage | ||||||||
120V AC/240V AC | 12V AC/24V AC | 50 | 2.8" | 3" | 3.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 75 | 2.8" | 3" | 3.8" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC/24V AC | 100 | 3.1" | 3.4" | 3.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 150 | 3.4" | 3.8" | 4.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 250 | 4" | 4 1/2" | 4 1/2" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 350 | 4" | 4 1/2" | 5.3" | UL Listed, CSA Certified | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 500 | 4.6" | 5.3" | 5.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 750 | 4.7" | 5.3" | 7" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 50 | 2.8" | 3" | 3.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 100 | 3" | 3.4" | 3.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 150 | 3.4" | 3.8" | 4.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 250 | 4" | 4 1/2" | 4.6" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 350 | 4" | 4 1/2" | 5.3" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 500 | 4.6" | 5.3" | 5.8" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 50 | 2.6" | 3" | 3.1" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 100 | 2.9" | 3.4" | 3.3" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 150 | 3.2" | 3.8" | 3.6" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 3.2" | 3.8" | 5.3" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 350 | 3.8" | 4 1/2" | 5.1" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 3.8" | 4 1/2" | 5 1/2" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 750 | 4 1/2" | 5.3" | 5.6" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,000 | 4 1/2" | 5.3" | 6.3" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,500 | 6.2" | 7.1" | 5.9" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 2,000 | 5.4" | 7" | 8.4" | UL Listed, C-UL Listed | 0000000 | 000000 |
Voltage | For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Type | O'all Dia. | Specifications Met | Each | |
Step Down Voltage | ||||||||||
120V AC/240V AC | 12V AC/24V AC | 50 | 4" | 3" | 3.6" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 0000000 |
230V AC/460V AC/575V AC | 95V AC/115V AC | 100 | 4.4" | 3.4" | 4.1" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 50 | 4" | 3" | 3.1" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 100 | 4.2" | 3.4" | 3.3" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 150 | 4 1/2" | 3.8" | 3.6" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 4 1/2" | 3.8" | 5.3" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 350 | 5.1" | 4 1/2" | 5.1" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 5.1" | 4 1/2" | 5 1/2" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 750 | 5.8" | 5.3" | 5.6" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,000 | 5.8" | 5.3" | 6.3" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,500 | 7.7" | 6.8" | 8.1" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 2,000 | 7.7" | 6.8" | 7.8" | UL Class CC Midget | 13/32" | UL Listed, CSA Certified | 0000000 | 000000 |
Touch-Safe High-Inrush Panel-Mount AC to AC Transformers
Prevent accidental contact with live electrical connections—the screw terminals are covered or recessed. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers.
Isolated coils protect equipment from input voltage spikes.
When wired for constant voltage, transformers filter out voltage spikes and electrical noise.
Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Features | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | |||||||||
Step Down Voltage | |||||||||
120V AC/240V AC | 24V AC | 50 | 2.8" | 3" | 3.3" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
120V AC/240V AC | 24V AC | 75 | 2.8" | 3" | 3.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 24V AC | 100 | 3.1" | 3.4" | 3.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
120V AC/240V AC | 24V AC | 150 | 3.4" | 3.8" | 4.3" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 24V AC | 250 | 4" | 4 1/2" | 4" | Covered Terminals, Isolated Coils | UL Listed, CSA Certified, CE Marked | 0000000 | 000000 |
120V AC/240V AC | 24V AC | 500 | 4.7" | 5.3" | 5.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 24V AC | 1,000 | 5.7" | 7" | 6.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 50 | 2.8" | 3" | 3.3" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 75 | 2.8" | 3" | 3.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 100 | 3.1" | 3.4" | 3.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 4" | 4 1/2" | 4.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 350 | 4" | 4 1/2" | 5.3" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 4.7" | 5.3" | 5.8" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 750 | 4.7" | 5.3" | 7" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,000 | 5.7" | 7" | 6.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 1,500 | 5.7" | 7" | 7.6" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 2,000 | 6" | 6.8" | 8.1" | Covered Terminals, Isolated Coils | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
Step Down/Constant Voltage | |||||||||
230V AC/460V AC/575V AC | 24V AC/115V AC/230V AC | 250 | 4" | 4 1/2" | 4.8" | Covered Terminals | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
230V AC/460V AC/575V AC | 24V AC/115V AC/230V AC | 300 | 4" | 4 1/2" | 5.3" | Covered Terminals | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
230V AC/460V AC/575V AC | 24V AC/115V AC/230V AC | 350 | 4 1/2" | 5.3" | 5.4" | Covered Terminals | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
230V AC/460V AC/575V AC | 24V AC/115V AC/230V AC | 500 | 4 1/2" | 5.3" | 6.6" | Covered Terminals | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
230V AC/460V AC/575V AC | 24V AC/115V AC/230V AC | 750 | 6" | 6.4" | 7.4" | Covered Terminals | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
230V AC/460V AC/575V AC | 24V AC/115V AC/230V AC | 1,000 | 6.3" | 6.8" | 7.8" | Covered Terminals | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
Harsh Environment High-Inrush Panel-Mount AC to AC Transformers
Sealed coils protect against dust, dirt, oil, and moisture. These transformers can handle momentary high-inrush current associated with contactors, solenoids, and relays. Also known as control transformers. Choose a transformer with multiple output voltages to simultaneously power multiple devices that require different output voltages.
Input and output fuse blocks are built-in and top-mounted to save panel space and allow quick installation.
Voltage | For Fuse | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | Type | O'all Dia. | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | ||||||||||
Step Down Voltage—Input Fuse Block | ||||||||||
120V AC/240V AC | 12V AC/24V AC | 50 | 4" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 75 | 4" | 3" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC/24V AC | 100 | 4.4" | 3.4" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 150 | 4.7" | 3.8" | 4.4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 250 | 5.3" | 4 1/2" | 4.6" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC/24V AC | 500 | 6" | 5.3" | 5.3" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
Step Down Voltage—Output Fuse Block | ||||||||||
120V AC/240V AC | 12V AC | 50 | 3.1" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC | 75 | 3.1" | 3" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
120V AC/240V AC | 12V AC | 100 | 3 1/2" | 3.4" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
120V AC/240V AC | 12V AC | 150 | 3.8" | 3.8" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 12V AC | 50 | 3.1" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 12V AC | 150 | 3.8" | 3.8" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
Step Down Voltage—Input and Output Fuse Block | ||||||||||
240V AC/480V AC | 120V AC | 50 | 4" | 3" | 3.8" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 75 | 4" | 3" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 100 | 4.3" | 3.4" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 00000 |
240V AC/480V AC | 120V AC | 150 | 4.7" | 3.8" | 4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 250 | 5.3" | 4 1/2" | 4.4" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
240V AC/480V AC | 120V AC | 500 | 6" | 5.3" | 6.1" | Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 50 | 3.9" | 3" | 3 1/2" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 75 | 4.2" | 3.4" | 3.6" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 100 | 4.2" | 3.8" | 3.6" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 150 | 4.7" | 3.8" | 4" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 200 | 5.3" | 4 1/2" | 4.4" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 250 | 4.1" | 4 1/2" | 4.4" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 300 | 5.9" | 5.3" | 5.2" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 350 | 5.9" | 5.3" | 5.2" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
230V AC/460V AC | 24V AC/115V AC | 500 | 6" | 5.3" | 5.7" | UL Class CC Midget | 13/32" | UL Listed, C-UL Listed | 0000000 | 000000 |
DIN-Rail/Panel-Mount High-Inrush AC to AC Transformers
Use with DIN-rail to install wherever you need these transformers or mount them to a panel. They can handle momentary high-inrush current associated with equipment start-up.
Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Ht. | Wd. | Dp. | For DIN Rail Size, mm | Specifications Met | Each | |
Single Phase—Screw Terminals Input and Output | |||||||||
Step Down Voltage | |||||||||
230V AC | 24V AC | 63 | 3 1/2" | 3.4" | 3.9" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 0000000 |
230V AC | 24V AC | 100 | 4" | 3.4" | 3.9" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 |
230V AC | 24V AC | 160 | 4.1" | 3.9" | 4.2" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 |
230V AC | 24V AC | 250 | 4.7" | 3.9" | 4.2" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 |
230V AC, 460V AC | 115V AC | 63 | 3 1/2" | 3.4" | 3.9" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 |
230V AC, 460V AC | 115V AC | 100 | 4" | 3.4" | 3.9" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 |
230V AC, 460V AC | 115V AC | 160 | 4.1" | 3.9" | 4.2" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 000000 |
230V AC, 460V AC | 115V AC | 250 | 4.7" | 3.9" | 4.2" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 00000000 |
230V AC, 460V AC | 115V AC | 400 | 4 1/2" | 4.8" | 4.8" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 00000000 |
230V AC, 460V AC | 115V AC | 500 | 5.3" | 4.8" | 4.8" | 35 | UL Recognized Component, C-UL Recognized Component, CE Marked | 0000000 | 00000000 |
Outlet Box/Panel-Mount High-Inrush AC to AC Transformers
Use the included mounting plate to mount these transformers to a panel. They can handle momentary high-inrush current associated with equipment start-up. Also known as control transformers, they are used in heating, ventilation, and air conditioning control circuits.
Voltage | |||||||||
---|---|---|---|---|---|---|---|---|---|
Input | Output | Power Output, VA | Wire Lead Lg. | Ht. | Wd. | Dp. | Specifications Met | Each | |
Single Phase—Wire Leads Input and Output | |||||||||
Step Down Voltage | |||||||||
120V AC, 208V AC, 240V AC | 24V AC | 40 | 6" | 2.8" | 3.7" | 2 1/2" | UL Recognized Component | 0000000 | 000000 |
120V AC | 24V AC | 40 | 6" | 2.8" | 3.7" | 2 1/2" | UL Recognized Component | 0000000 | 00000 |
208V AC, 240V AC | 24V AC | 40 | 6" | 2.8" | 3.7" | 2 1/2" | UL Recognized Component | 0000000 | 00000 |