Filter by
Line Break Detectors
Long-Reach-Tip Sensor End, Sheathed-Alligator-Clip Sensor End | Probe-Tip Sensor End, Sheathed-Alligator-Clip Sensor End | Test-Lead Sensor End with Replaceable Alligator Clips |
Check continuity in circuits. If there are no line breaks, light or sound alerts signal continuity.
Test Leads | Batteries | Replacement Test Leads | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Measures | Alert Type | No. of | Lg. | Included | Size | No. Required | Each | Pair | |||
Long-Reach Tip, Sheathed Alligator Clip | Continuity, Ground Faults | Light | 1 | 72" | Yes | CR2 | 1 | 0000000 | 000000 | __ | 00 | |
Probe Tip, Sheathed Alligator Clip | Continuity | Light | 1 | 36" | Yes | AAA | 2 | 0000000 | 0000 | __ | 00 | |
Test Leads with Replaceable Alligator Clips | Continuity | Sound | 2 | 48" | No | 9V | 1 | 0000000 | 000000 | 0000000 | 000000 |
Voltage Detectors
Confirm that voltage is present in receptacles, cables, and other electrical components. The detectors have light or sound alerts to indicate voltage.
Voltage Detectors
Long-Reach-Tip Sensor End—12-250V AC | Long-Reach-Tip Sensor End—6-50V DC | Test-Lead Sensor End with Sheathed Alligator Clips |
Test-Lead Sensor End with Needle Tips | Noncontact Sensor End—12-1,000V AC | Noncontact Sensor End—50-1,000V AC |
Long-Reach-Tip Sensor End—Long-reach tips must touch the electrical component you're testing to sense voltage.
Test-Lead Sensor End with Sheathed Alligator Clips—Tests leads with sheathed alligator clips must touch the electrical component you're testing to sense voltage.
Test-Lead Sensor End with Needle Tips—Test leads with needle tips must touch the electrical component you're testing to sense voltage.
Noncontact Sensor End—Noncontact detectors can sense voltage when brought near the electrical component.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Electrical Safety Rating | AC Voltage Range, V AC | DC Voltage Range, V DC | Measures | Alert Type | Req. | Included | Certification | Each | ||
Long-Reach Tip | __ | __ | 6 to 50 | DC Voltage | Light, Sound | No | __ | UL Listed, C-UL Listed | 00000000 | 000000 | |
Long-Reach Tip | CAT III, 250V | 12 to 250 | 12 to 250 | AC Voltage, Continuity, DC Voltage | Light | Yes | Yes | ETL Listed, C-ETL Listed | 0000000 | 00000 | |
Test Leads with Sheathed Alligator Clips | CAT I, 50V | 5 to 50 | 5 to 50 | AC Voltage, DC Voltage | Light | No | __ | ETL Listed, C-ETL Listed | 0000000 | 0000 | |
Test Leads with Needle Tips | CAT III, 600V | 120 to 480 | 160 to 600 | AC Voltage, DC Voltage | Light | No | __ | CSA Certified | 0000000 | 00000 | |
Noncontact | CAT IV, 600V | 12 to 1,000 | __ | AC Voltage | Light, Sound | Yes | Yes | ETL Listed, C-ETL Listed | 00000000 | 00000 | |
Noncontact | CAT IV, 1,000V | 50 to 1,000 | __ | AC Voltage | Light, Sound | Yes | Yes | UL Listed, C-UL Listed | 00000000 | 00000 |
Fluke Voltage Detectors
Long-Reach-Tip Sensor End |
Long-Reach-Tip Sensor End—Long-reach tips must touch the electrical component you're testing to sense voltage.
Batteries | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Sensor End | Mfr. Model No. | Electrical Safety Rating | AC Voltage Range, V AC | Measures | Alert Type | Req. | Included | Certification | Each | ||
Long-Reach Tip | 1AC-II | CAT IV, 1,000V | 90 to 1,000 | AC Voltage | Light, Sound | Yes | Yes | CSA Certified, CSA-US Certified | 0000000 | 000000 | |
Long-Reach Tip | 1LAC-II | CAT IV, 1,000V | 20 to 90 | AC Voltage | Light, Sound | Yes | Yes | CSA Certified, CSA-US Certified | 0000000 | 00000 |
High-Voltage Detectors
Safely check for the presence of voltage in high-voltage equipment and lines. Light and sound alerts indicate voltage.
Noncontact Sensor End—Noncontact detectors can sense voltage when brought near the electrical component.
Hot Stick (48" Lg.)—For testing 1,500-122,000V AC, a hot stick is required (not included). It attaches to the high-voltage detector to extend your reach and detect voltage from a distance.
Batteries | |||||||||
---|---|---|---|---|---|---|---|---|---|
Sensor End | AC Voltage Range, V AC | Measures | Alert Type | Includes | Req. | Included | Each | ||
Noncontact | 30 to 122,000 | AC Voltage | Light, Sound | Carrying Case | Yes | Yes | 0000000 | 0000000 |
Fluke Vibrating Voltage Meters
Detect voltage with three types of alerts for extra safety—light, sound, and vibration. There are LEDs that light up to show the approximate voltage level, and a digital LCD shows precise voltage measurements. Fluke meters are known for quality and durability.
Batteries | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | Electrical Safety Rating | Measures | Voltage Increments | Max. Resistance | Alert Type | Display Type | Display Features | Includes | Lead Lg. | Certification | Req. | Included | Each | ||
T+Pro | CAT IV, 600V | AC Voltage, Continuity, DC Voltage, Resistance | 12V, 24V, 48V, 120V, 208V, 240V, 277V, 480V, 600V | 10 kΩ | Light, Sound, Vibration | Digital, Light Indicator | Backlight | Test Leads | 34" | UL Listed, C-UL Listed | Yes | Yes | 0000000 | 0000000 |
Vibrating Voltage Meters
In addition to vibrating to confirm the presence of voltage, these meters have LEDs that light up to show an approximate voltage level.
AC Voltage, V AC | DC Voltage, V DC | Batteries | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Electrical Safety Rating | Measures | Min. | Max. | Min. | Max. | Alert Type | Display Type | Includes | Lead Lg. | Certification | Req. | Included | Each | ||
CAT III, 600V | AC Voltage, DC Voltage | 100 | 600 | 100 | 600 | Light, Vibration | Light Indicator | Test Leads | 28" | UL Listed, C-UL Listed | No | __ | 0000000 | 000000 | |
CAT III, 600V | AC Voltage, Continuity, DC Voltage | 5 | 600 | 5 | 600 | Light, Vibration | Light Indicator | Test Leads | 28" | UL Listed, C-UL Listed | Yes | Yes | 0000000 | 00000 |
Fluke Wireless Remote-Reading Voltage Meters
Measure voltage from a distance with these wireless connection-enabled meters that transmit readings to a separate display. Fluke is known for quality and durability.
The meters work with the Fluke 3000 FC multimeter, a computer with a Fluke pc3000 FC connector plugged in (not included), or a mobile device that has the Fluke Connect app.
True RMS AC Calculation—The true RMS meter takes accurate AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. These 1,000-count meters show numbers up to 999.
Batteries | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Mfr. Model No. | AC Calculation | Electrical Safety Rating | Measures | Max. AC Voltage, V AC | Max. DC Voltage, V DC | Display Type | Display Features | Data Log Cap. | Display Count | Includes | Certification | Req. | Included | Each | ||
v3000 FC | True RMS | CAT IV, 600V | AC Voltage | 1,000 | __ | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 0000000 | |
v3001 FC | __ | CAT IV, 600V | DC Voltage | __ | 1,000 | Digital | Backlight | 65,000 | 1,000 | Alligator Clips, Magnetic Hanger, Test Leads | CSA Certified, CSA-US Certified | Yes | Yes | 00000000 | 000000 |
Data Cable Testing Adapters
Attach the included cord to an RJ45 wall outlet to isolate the signals of a data line, and use alligator clips to connect your testing device.
No. of Test Connections | Includes | Each | ||
---|---|---|---|---|
8 | Cord with RJ45 Plugs | 000000 | 000000 |
Line Testers
Diagnose problems with analog and digital telephone lines.
Display | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Measures | Alert Type | Type | Features | Includes | Batteries Included | No. of Batteries Req. | Battery Size | Each | ||
DC Current, DC Voltage, Dial Tone | Light | Digital | Call Waiting, Caller ID, Number Dialed | Headset, Test Leads with Alligator Clips and RJ11 Plug | No | 2 | AA | 00000000 | 0000000 |
Tone-Generating Line Testers
RJ11 Plug | RJ45 Plug |
Generate an audible signal when testing for short circuits, line continuity, or when locating a cable. Use an amplifier (sold separately) to hear the signal. These tone generators have a light signal to verify polarity.
Line Tester Pouches | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Measures | Alert Type | Features | Includes | Batteries Included | No. of Batteries Req. | Battery Size | Each | Each | |||
Cable Location, Continuity, Polarity | Light, Sound | RJ11 Plug | Test Leads with Alligator Clips | No | 1 | 9V | 0000000 | 000000 | 00000000 | 000000 | |
Cable Location, Continuity, Polarity | Light, Sound | RJ45 Plug | Test Leads with Alligator Clips | No | 1 | 9V | 0000000 | 000000 | 00000000 | 00000 |
Noise-Filtering Line Testing Amplifiers
Block out power-line hum when identifying a cable. Use this amplifier with a tone generator or tester to identify a cable without making direct contact with the wire. The tone will get louder the closer you get to the correct cable.
Line Testing Amplifiers
Use this amplifier with a tone generator or tester to identify a cable without making direct contact with the wire. The tone will get louder the closer you get to the correct cable.
Line Tester Adapters
Attach the included cord to an RJ11 wall outlet to isolate the signals of a telephone line, and use alligator clips to connect your testing device.
No. of Test Connections | Includes | Each | ||
---|---|---|---|---|
6 | Cord with RJ11 Plugs | 000000 | 000000 |