About Air Preparation
More
About Air Compressors
More
Compressed Air Regulating Manifolds
Use a single air supply to meet the pressure requirements of multiple applications—connect one of these manifolds to your air line, and then set a different output pressure for each station. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Pipe Size | Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
No. of Stations | Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Pressure Regulating Range, psi | Each | |
Aluminum Housing—NPT Female Inlet and Outlet | |||||||||||
±1.6% Accuracy | |||||||||||
2 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 3 1/4" | 4 7/8" | 140° | 4.4-176 | 0000000 | 0000000 |
2 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 6 1/4" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
4 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 6 3/8" | 4 7/8" | 140° | 4.4-176 | 0000000 | 000000 |
4 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 12 3/8" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
6 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 9 5/8" | 4 7/8" | 140° | 4.4-176 | 0000000 | 000000 |
6 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 18 5/8" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
8 | 1/4 | 1/4 | 65 scfm @ 100 psi | 206 | Yes | 12 3/4" | 4 7/8" | 140° | 4.4-176 | 0000000 | 000000 |
8 | 1/2 | 1/2 | 230 scfm @ 100 psi | 290 | Yes | 24 3/4" | 7 3/8" | 140° | 4.4-174 | 0000000 | 000000 |
±3.5% Accuracy | |||||||||||
2 | 1/8 | 1/8 | 4 scfm @ 100 psi | 120 | Yes | 2 1/4" | 1 3/8" | 140° | 7-102 | 0000000 | 000000 |
3 | 1/8 | 1/8 | 4 scfm @ 100 psi | 120 | Yes | 3" | 1 3/8" | 140° | 7-102 | 0000000 | 000000 |
4 | 1/8 | 1/8 | 4 scfm @ 100 psi | 120 | Yes | 3 3/4" | 1 3/8" | 140° | 7-102 | 0000000 | 000000 |
Norgren Modular Compressed Air Regulator Manifolds
Connect two or more of these manifold regulators to meet multiple pressure requirements from a single air supply—set a different output pressure with each regulator. Each regulator has two regulated outlets and one unregulated outlet. Regulators are relieving style, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Mounting brackets (sold separately) allow you to attach manifold regulators to a wall or equipment.
Joiner clamps (sold separately) connect manifold regulators to each other and other Norgren modular components with the same series number. They come with mounting brackets.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
Regulator Manifolds | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Joiner Clamps | End Block Sets | ||||||||||||
Manufacturer Series | Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Max. Temp., °F | Choose a Pressure Regulating Range, psi | Each | Each | Each | |||
Zinc Housing | ||||||||||||||
Series No. 72—NPT Female Inlet and Outlets | ||||||||||||||
R72 | 1/4 | 1/4 (1 Unregulated), 1/4 (1 Regulated), 1/8 (1 Regulated) | 83 cfm @ 100 psi | 300 | 2" | 4 1/4" | 150° | 000000 | 000000 | 000000 | 000000 | 0000000 | 000000 | |
R72 | 3/8 | 3/8 (1 Unregulated), 1/4 (1 Regulated), 1/8 (1 Regulated) | 83 cfm @ 100 psi | 300 | 2" | 4 1/4" | 150° | 000000 | 00000 | 000000 | 00000 | 0000000 | 00000 | |
Aluminum Housing | ||||||||||||||
Series No. 74—NPT Female Inlet and Outlets | ||||||||||||||
R74 | 1/2 | 1/2 (1 Unregulated), 1/2 (1 Regulated), 1/8 (1 Regulated) | 160 scfm @ 100 psi | 300 | 3 1/8" | 6 5/8" | 175° | 5-150 | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 |
R74 | 3/4 | 3/4 (1 Unregulated), 1/2 (1 Regulated), 1/8 (1 Regulated) | 160 scfm @ 100 psi | 300 | 3 1/8" | 6 5/8" | 175° | 5-150 | 00000000 | 000000 | 000000 | 00000 | 0000000 | 00000 |
Wilkerson Modular Compressed Air Regulator Manifolds
Connect two or more of these manifold regulators to meet multiple pressure requirements from a single air supply—set a different output pressure with each regulator. Each regulator has two regulated outlets, one unregulated outlet, and an additional port that can be used for a pressure gauge (not included). Regulators are relieving style, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Joiner clamps (sold separately) connect manifold regulators to each other and other Wilkerson modular components with the same series number. They come with mounting brackets to attach the regulator to a wall or equipment.
End block sets (sold separately) allow you to swap out filter/regulator/lubricator components without unthreading your air line connections. The blocks remain connected to your pipe while you replace components between them.
For technical drawings and 3-D models, click on a part number.
Regulator Manifolds | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Overall | Joiner Clamps | End Block Sets | ||||||||||||
Manufacturer Series | Inlet Pipe Size | Outlet Pipe Size (No. of Outlets) | Max. Flow Rate | Max. Pressure, psi | Wd. | Ht. | Max. Temp., °F | Choose a Pressure Regulating Range, psi | Each | Each | Each | |||
Aluminum Housing | ||||||||||||||
Series No. 09—NPT Female Inlet and Outlets | ||||||||||||||
R09 | 1/4 | 1/4 (1 Unregulated), 1/8 (2 Regulated) | 29 scfm @ 100 psi | 300 | 1 5/8" | 4" | 150° | 0000000 | 000000 | 00000000 | 00000 | 00000000 | 000000 | |
Series No. 19—NPT Female Inlet and Outlets | ||||||||||||||
R19 | 1/4 | 1/4 (1 Unregulated), 1/4 (2 Regulated) | 62 scfm @ 100 psi | 300 | 2 3/8" | 5 1/2" | 150° | 0000000 | 00000 | 00000000 | 00000 | 0000000 | 00000 | |
R19 | 3/8 | 3/8 (1 Unregulated), 1/4 (2 Regulated) | 62 scfm @ 100 psi | 300 | 2 3/8" | 5 1/2" | 150° | 0000000 | 00000 | 00000000 | 00000 | 00000000 | 00000 | |
R19 | 1/2 | 1/2 (1 Unregulated), 1/4 (2 Regulated) | 62 scfm @ 100 psi | 300 | 2 3/8" | 5 1/2" | 150° | 0000000 | 00000 | 00000000 | 00000 | 00000000 | 00000 |
Compressed Air Regulating Manifolds for Air-Powered Tools
Run up to four air-powered tools from a single air supply. Two outlets deliver air at the same pressure as the air supply, and two outlets share a regulator so you can turn the knob to adjust the pressure within the range. The pressure gauge indicates air pressure at the regulated outlets.
Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Inlet Tube ID | Outlet Coupling Size (No. of Outlets) | Outlet Coupling Type | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Lg. | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy | Pressure Regulating Range, psi | Each | |
Zinc Housing | |||||||||||||
Plug-In Male Inlet × Push-to-Connect Female Outlet | |||||||||||||
3/8" | 1/4 (2 Unregulated, 2 Regulated) | ARO Quick-Disconnect, Industrial Quick-Disconnect | 20 scfm @ 100 psi | 200 | Yes | 12 1/2" | 7" | 4" | 120° | ±3% | 0-150 | 0000000 | 000000 |
Manifolds for Supplied-Air Respirators for Plant Air Lines
Divert compressed air from a single line to two respirators. Often used in plants with limited air sources, these manifolds allow two workers to share the same line. Shaped like a briefcase, they’re easy to tote around your facility—use them up to 300 ft. from an air source. The case is polypropylene, so it’s durable enough to hold up to wear and tear.
Overall | Pressure Regulating Max., psi | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet Coupling Size | Outlet Coupling Size (No. of Outlets) | Max. Flow Rate, cfm | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy, psi | Inlet | Outlet | Each | |
Aluminum Housing | ||||||||||||
Quick-Disconnect Male Inlet and Female Outlets | ||||||||||||
1/2 | 1/4 (2 Regulated) | 100 | 125 | Yes | 19" | 13" | 140° | ±0.1 | 150 | 125 | 0000000 | 0000000 |