Clean Room Hoods


Prevent dust, microbes and other pollutants from contaminating a clean room. When laundered to clean room standards, these hoods can be reused up to 100 times. Wash them prior to first use and after each use.
All hoods are suitable for use in clean rooms rated to both Federal Standard and ISO classes. In both standards, clean rooms with lower class ratings have fewer contaminants.
Polyester/carbon fiber hoods discharge static electricity and prevent the buildup of static from harming electronic equipment.
Polyester hoods withstand liquid splashes and abrasion.
Environmental Rating | Hood Style | Material | Surface Resistivity, ohms/sq. | Closure Type | Features | Color | Size | Each | |
Fed. Std. Class 1,000, ISO Class 6 | Open Face | Polyester/Carbon Fiber Fabric Blend | 107 | Snaps | __ | White | 00000000 | 000000 | |
Fed. Std. Class 1,000, ISO Class 6 | Covered Face | Polyester Fabric | __ | Snaps | Detachable Face Cover | White | 0000000 | 00000 |
Disposable Clean Room Hoods

Designed to meet clean room standards, these hoods prevent dust particles and microbes on you from contaminating a space. Made of Tyvek polyethylene, they hold up to limited contact with nonhazardous liquids, such as water and paint spray. The heat- and pressure-bonded fibers make these hoods soft yet strong. You can throw them out after you’re done using them.
Environmental Rating | Hood Style | Material | Closure Type | Color | Size | Each | |
ISO Class 5 | Open Face | Tyvek Polyethylene Fabric | Tie | White | One Size | 0000000 | 00000 |
Bench-Top Air Cleaner Hoods
Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a pre-filter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Fed. Std. Class 100 and ISO Class 5 clean room requirements.
As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
For technical drawings and 3-D models, click on a part number.

Overall | Work Surface | Housing | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Ht. | Wd. | Dp. | Wd. | Dp. | Material | Color | Panel Cutout Dia. | Environmental Rating | Each | |
304L Stainless Steel Work Surface with Acrylic Enclosure | ||||||||||||||
Hoods | ||||||||||||||
185 | 59 dBA @ 5 ft. | 120V AC | 3A | 47 3/4" | 31 3/4" | 24 1/4" | 26 1/2" | 20 1/2" | Plastic | Black, Blue, White | 2 7/8" | Fed. Std. Class 100, ISO Class 5 | 0000000 | 000000000 |
Overall | ||||||
---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Material | Wheel Configuration | Each | |
Mobile | ||||||
34 7/8" | 30 3/4" | 24 1/4" | Galvanized Steel | Four Swivel Casters (Two with Brakes) | 0000000 | 0000000 |