About Air Preparation
More
Bench-Top Air Cleaner Hoods
Filtering away dust and particles, these hoods create a clean space for demanding work, such as bioprocessing, pharmaceuticals, electronics, and optics. They have a HEPA H14 filter to catch 99.995% of particles down to 0.1 microns, as well as a pre-filter to pull out large particles before they reach the HEPA filter. To draw air from outside the hood into the filters, they have a fan; there’s no need to connect them to ductwork. A flow monitor tracks the airflow and alerts you with a visible and audible alarm if the fan fails. They meet Fed. Std. Class 100 and ISO Class 5 clean room requirements.
As an alternative to filtering the air of an entire room, these hoods leave a large enough opening for comfortable access inside and have internal fluorescent lighting to help you see your work. Their work surface is 304L stainless steel, which resists bacteria and chemicals, and also is easy to clean. Mount them on workbenches and carts that are designed to hold them, or place them on your own bench top.
For technical drawings and 3-D models, click on a part number.
Overall | Work Surface | Housing | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Airflow, cfm | Volume | Voltage | Current | Ht. | Wd. | Dp. | Wd. | Dp. | Material | Color | Panel Cutout Dia. | Environmental Rating | Each | |
304L Stainless Steel Work Surface with Acrylic Enclosure | ||||||||||||||
Hoods | ||||||||||||||
185 | 59 dBA @ 5 ft. | 120V AC | 3A | 47 3/4" | 31 3/4" | 24 1/4" | 26 1/2" | 20 1/2" | Plastic | Black, Blue, White | 2 7/8" | Fed. Std. Class 100, ISO Class 5 | 0000000 | 000000000 |
Overall | ||||||
---|---|---|---|---|---|---|
Ht. | Wd. | Dp. | Material | Wheel Configuration | Each | |
Mobile | ||||||
34 7/8" | 30 3/4" | 24 1/4" | Galvanized Steel | Four Swivel Casters (Two with Brakes) | 0000000 | 0000000 |
Clean Room Compressed Air Filters for Particle Removal
Assembled, inspected, and packaged in a clean environment, these filters come sealed in antistatic double bags. Use them to remove particles and water droplets from your compressed air to extend the service life of air-powered tools and equipment. Filters have a clear bowl so you can see inside to monitor contents.
For technical drawings and 3-D models, click on a part number.
O'all | |||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | Max. Flow Rate | Max. Pressure, psi | Removes Particle Size Down To, microns | Includes | Ht. | Wd. | Environmental Rating | Each | |
NPT Female Inlet and Outlet | |||||||||
Polycarbonate Plastic Bowl—Clear Without Drain | |||||||||
1/8 | 53 scfm @ 100 psi | 145 | 5 | Mounting Bracket | 4" | 1 5/8" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 000000 |
1/4 | 128 scfm @ 100 psi | 145 | 5 | Mounting Bracket | 5 3/8" | 2 1/8" | Fed. Std. Class 1, ISO Class 3 | 000000 | 00000 |
3/8 | 128 scfm @ 100 psi | 145 | 5 | Mounting Bracket | 5 3/8" | 2 1/8" | Fed. Std. Class 1, ISO Class 3 | 000000 | 00000 |
1/2 | 206 scfm @ 100 psi | 145 | 5 | Mounting Bracket | 6 3/4" | 2 3/4" | Fed. Std. Class 1, ISO Class 3 | 000000 | 00000 |
3/4 | 212 scfm @ 100 psi | 145 | 5 | Mounting Bracket | 7" | 3" | Fed. Std. Class 1, ISO Class 3 | 000000 | 00000 |
1 | 427 scfm @ 100 psi | 145 | 5 | Mounting Bracket | 10" | 3 5/8" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 00000 |
Clean Room Compressed Air Filter/Regulators for Particle Removal
Assembled, inspected, and packaged in a clean environment, these filter/regulators come sealed in antistatic double bags. The filter and regulator are joined top-to-bottom to fit in the same space as a filter alone. They provide clean compressed air at your required pressure. Filter has a clear bowl so you can see inside to monitor contents. Regulator is relieving style, so it exhausts when the downstream pressure exceeds the set pressure. The drain stays open. To close the drain and maintain the integrity of the clean room, attach a valve or closure (not included).
Filter/Regulators | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Drain | Overall | Replacement Filter Elements | |||||||||||||
Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Removes Particle Size Down To, microns | Pipe Size | Thread Type | Gender | Pressure Regulating Range, psi | Includes | Wd. | Ht. | Environmental Rating | Each | Each | ||
NPT Female Inlet and Outlet | ||||||||||||||||
Polycarbonate Plastic Bowl—Clear with Manual Drain | ||||||||||||||||
1/8 | 1/8 | 28 scfm @ 100 psi | 145 | 5 | 1/8 | NPT | Female | 7.25-123 | Mounting Bracket | 2 5/8" | 6 1/2" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 000000 | 000000 | 00000 |
1/4 | 1/4 | 53 scfm @ 100 psi | 145 | 5 | 1/4 | NPT | Female | 7.25-123 | Mounting Bracket | 2 1/8" | 8 1/8" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 00000 | 000000 | 0000 |
3/8 | 3/8 | 53 scfm @ 100 psi | 145 | 5 | 1/4 | NPT | Female | 7.25-123 | Mounting Bracket | 2 1/8" | 8 1/8" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 00000 | 000000 | 0000 |
1/2 | 1/2 | 106 scfm @ 100 psi | 145 | 5 | 1/4 | NPT | Female | 7.25-123 | Mounting Bracket | 3 3/4" | 9 5/8" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 00000 | 000000 | 0000 |
3/4 | 3/4 | 141 scfm @ 100 psi | 145 | 5 | 1/4 | NPT | Female | 7.25-123 | Mounting Bracket | 3" | 9 3/4" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 000000 | 000000 | 0000 |
1 | 1 | 353 scfm @ 100 psi | 145 | 5 | 1/4 | NPT | Female | 7.25-123 | Mounting Bracket | 3 3/4" | 16 1/2" | Fed. Std. Class 1, ISO Class 3 | 0000000 | 000000 | 0000000 | 00000 |