Panel-Mount Equipment Circuit Breakers
Mount these breakers, also known as supplemental protectors, through panels downstream from a branch circuit breaker to protect a single piece of equipment. They are rated UL1077 for protection against overloads and short circuits. These breakers can also be used as on/off switches. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.
Current, A | Voltage | Frequency, Hz | Breakthrough Current | For Panel Cutout Dia. | Dp. Behind Panel | Mounting Fasteners Included | Quick-Disconnect Tab Wd. | Temp. Range, °F | Specifications Met | Each | |
1 Pole | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/20 | 250V AC/75V DC | 50/60 | 200 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 000000 |
2/10 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
4/10 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
1/2 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
6/10 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
8/10 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
1 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
1 1/2 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
2 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
2 1/2 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
3 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
4 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
5 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
6 | 250V AC/75V DC | 50/60 | 1,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
8 | 250V AC/75V DC | 50/60 | 2,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
10 | 250V AC/75V DC | 50/60 | 2,000 A @ 250 V AC 800 A @ 75 V DC | 1/4" | 2.42" | Yes | 0.25" | -20° to 140° | UL 1077, UL Recognized Component | 0000000 | 00000 |
Harsh-Environment Circuit Breakers
Built to resist vibration and corrosion in harsh environments, these circuit breakers protect against overload and short circuits in low-voltage automotive and other electronic applications. All are thermal, so they use the heat generated in overcurrent situations to trip the breaker.
Breakthrough current is the maximum current that the circuit breaker can safely stop in the event of a short circuit.
Push-pull button and lever style breakers can be used as an on/off switch.
Place UL1077 rated breakers downstream from a branch circuit breaker to protect a single piece of equipment. They are also known as supplemental protectors.
For technical drawings and 3-D models, click on a part number.
Current, A | Voltage | Breakthrough Current | For Panel Cutout Dia. | Dp. Behind Panel | Mount Type | Mounting Fasteners Included | Wire Connection Type | Temp. Range, °F | Specifications Met | Each | |
1 Pole | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
30 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 000000 |
35 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
40 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
45 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
50 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
55 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
60 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
70 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
80 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |
90 | 28V DC | 6,000 A @ 28 V DC | 0.49" | 2.48" | Screw On | Yes | Screw Terminals | -65° to 165° | UL 1077, UL Recognized Component | 0000000 | 00000 |