Precision Turn-Lock Push/Pull Control Cables
Use these cables for high-precision motion control. Tighten the locknut to secure your setting in applications where severe vibration is a concern. Flexible for weaving around obstructions, these ready-to-use cables operate valves, throttle controls, and HVAC damper controls from a distance. The cable can be cut to length. It can also be panel mounted.
Cable | Dynamic Load Cap., lbs. | Knob | Panel-Mount Cables | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | OD | Core Dia. | Max. Stroke Lg. | Push | Pull | Bend Radius | Material | Dia. | Thread Size | Temp. Range, °F | Each | |
Stainless Steel Cable Core with Plastic Cover | ||||||||||||
5' | 0.31" | 0.085" | 3" | 25 | 25 | 6" | Plastic | 1.62" | 3/4"-16 | -40° to 225° | 000000 | 000000 |
10' | 0.31" | 0.085" | 3" | Not Rated | Not Rated | 6" | Plastic | 1 1/2" | 3/4"-16 | -40° to 225° | 0000000 | 000000 |
15' | 0.31" | 0.085" | 3" | Not Rated | Not Rated | 6" | Plastic | 1 1/2" | 3/4"-16 | -40° to 225° | 0000000 | 000000 |
25' | 0.31" | 0.085" | 3" | Not Rated | Not Rated | 6" | Plastic | 1 1/2" | 3/4"-16 | -40° to 225° | 0000000 | 000000 |
Turn-Lock Push/Pull Control Cables
Pull and turn the knob to lock, so it's secure in applications where severe vibration is a concern. Flexible for weaving around obstructions, these ready-to-use cables operate valves, throttle controls, and HVAC damper controls from a distance. These cables can be panel mounted.
Cable | Dynamic Load Cap., lbs. | Knob | Panel-Mount Cables | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | OD | Core Dia. | Max. Stroke Lg. | Push | Pull | Bend Radius | Material | Dia. | Thread Size | Mount Type | Temp. Range, °F | Cable Connection Type | Features | Each | |
Stainless Steel Cable Core with Plastic Cover | |||||||||||||||
8' | 0.45" | 0.132" | 2" | Not Rated | Not Rated | 8" | Plastic | 2 1/2" | 1/4"-28 | Grooved Clamp | -40° to 225° | Screw | 1/4"-28 Threaded Male End | 0000000 | 0000000 |
8' | 0.45" | 0.132" | 2" | Not Rated | Not Rated | 8" | Plastic | 2 1/2" | 1/4"-28 | Through Wall | -40° to 225° | Screw | 1/4"-28 Threaded Male End | 0000000 | 000000 |
9' | 0.31" | 0.085" | 3" | 25 | 25 | 6" | Plastic | 2 1/2" | 5/8"-18 | __ | -40° to 225° | __ | __ | 0000000 | 00000 |
10' | 0.45" | 0.132" | 2" | Not Rated | Not Rated | 8" | Plastic | 2 1/2" | 1/4"-28 | Through Wall | -40° to 225° | Screw | 1/4"-28 Threaded Male End | 0000000 | 000000 |
15' | 0.31" | 0.085" | 3" | 25 | 25 | 6" | Plastic | 2 1/2" | 5/8"-18 | __ | -40° to 225° | __ | __ | 0000000 | 00000 |
25' | 0.31" | 0.085" | 3" | 25 | 25 | 6" | Plastic | 2 1/2" | 5/8"-18 | __ | -40° to 225° | __ | __ | 0000000 | 00000 |
Trigger-Lever Push/Pull Control Cables
Control this flexible, ready-to-use cable with the attached trigger-style spring-return lever. Weave it around obstructions to operate valves, throttle controls, and HVAC damper controls from a distance. It can be mounted to a tube with a screw (not included).
Cable | Dynamic Load Cap., lbs. | Lever | Tube-Mount Cables | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | OD | Core Dia. | Max. Stroke Lg. | Push | Pull | Bend Radius | For Mount. Tube Dia. | Material | Actuation | Ht. | Lg. | Temp. Range, °F | Mount. Fasteners Included | For Screw Size | No. of Mount. Holes | Mount. Hole Dia. | Each | |
Steel Cable Core with Plastic Cover | ||||||||||||||||||
10' | 0.22" | 0.06" | 0.69" | 20 | 20 | 3 1/2" | 3/4"-1" | Plastic | Hand | 1 1/2" | 3 3/4" | 0° to 120° | No | No. 10 | 1 | 0.2" | 0000000 | 000000 |
Push/Pull Control Cables
Use the attached knob to control these flexible, ready-to-use cables. Weave them around obstructions to operate valves, throttle controls, and HVAC damper controls from a distance. The cables can be cut to length. They can also be panel mounted.
Cable | Dynamic Load Cap., lbs. | Knob | Panel-Mount Cables | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg. | OD | Core Dia. | Max. Stroke Lg. | Push | Pull | Bend Radius | Material | Dia. | Thread Size | Temp. Range, °F | Each | |
Stainless Steel Cable Core with Plastic Cover | ||||||||||||
10'8" | 0.31" | 0.085" | 5" | 50 | 50 | 6" | Plastic | 2" | 3/8"-24 | -40° to 225° | 000000 | 000000 |
15'8" | 0.31" | 0.085" | 5" | 50 | 50 | 6" | Plastic | 2" | 3/8"-24 | -40° to 225° | 000000 | 00000 |
Create-Your-Own Push/Pull Control Cables
Pair these cables with a knob or lever (not included) to operate valves, throttle controls, and HVAC damper controls from a distance. They're flexible for weaving around obstructions.
Clamp-mount cables have threaded fittings on both ends and a grooved body for mounting with strap clamps or U-bolts.
Panel-mount cables are also known as bulkhead mount cables. They have threaded fittings with hex nuts and washers at each end for mounting through a panel.
For technical drawings and 3-D models, click on a part number.
Thread | Dynamic Load Cap., lbs. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | Lg. | O'all Lg., ft. | Max. Stroke Lg. | Push | Pull | Bend Radius | Temp. Range, °F | For Clamp Hole Dia. | Fitting Lg. | Each | |
Stainless Steel Cable Core with Plastic Cover | |||||||||||
10-32 | 7/8" | 3 | 2" | 50 | 50 | 8" | -40° to 210° | 7/16" | 6 1/2" | 0000000 | 000000 |
10-32 | 7/8" | 6 | 2" | 50 | 50 | 8" | -40° to 210° | 7/16" | 6 1/2" | 0000000 | 00000 |
10-32 | 7/8" | 6 | 3" | 40 | 40 | 6" | -65° to 225° | 3/8" | 7 63/64" | 00000000 | 00000 |
1/4"-28 | 1" | 3 | 4" | 65 | 65 | 6" | -65° to 225° | 1/2" | 10 13/64" | 00000000 | 00000 |
1/4"-28 | 1" | 6 | 3" | 75 | 75 | 6" | -65° to 225° | 1/2" | 8 45/64" | 00000000 | 000000 |
1/4"-28 | 1" | 6 | 4" | 65 | 65 | 6" | -65° to 225° | 1/2" | 10 13/64" | 00000000 | 00000 |
1/4"-28 | 1" | 6 | 6" | 60 | 60 | 6" | -65° to 225° | 1/2" | 13 13/64" | 00000000 | 00000 |
5/16"-24 | 1 3/16" | 6 | 4" | 140 | 140 | 6" | -65° to 225° | 37/64" | 10 37/64" | 00000000 | 00000 |
Thread | Dynamic Load Cap., lbs. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | Lg. | O'all Lg., ft. | Max. Stroke Lg. | Push | Pull | Bend Radius | Temp. Range, °F | For Panel Cutout Dia. | Fitting Lg. | Each | |
Stainless Steel Cable Core with Plastic Cover | |||||||||||
10-32 | 7/8" | 3 | 2" | 50 | 50 | 8" | -40° to 210° | 7/16" | 7 5/16" | 0000000 | 000000 |
10-32 | 7/8" | 3 | 3" | 40 | 40 | 6" | -65° to 225° | 7/16" | 8 13/16" | 00000000 | 00000 |
10-32 | 7/8" | 3 | 4" | 30 | 30 | 6" | -65° to 225° | 7/16" | 10 5/16" | 00000000 | 00000 |
10-32 | 7/8" | 6 | 2" | 50 | 50 | 8" | -40° to 210° | 7/16" | 7 5/16" | 0000000 | 00000 |
10-32 | 7/8" | 6 | 3" | 40 | 40 | 6" | -65° to 225° | 7/16" | 8 13/16" | 00000000 | 00000 |
10-32 | 7/8" | 6 | 4" | 30 | 30 | 6" | -65° to 225° | 7/16" | 10 5/16" | 00000000 | 000000 |
1/4"-28 | 1" | 3 | 3" | 75 | 75 | 6" | -65° to 225° | 5/8" | 9 5/8" | 00000000 | 000000 |
1/4"-28 | 1" | 3 | 4" | 65 | 65 | 6" | -65° to 225° | 5/8" | 11 1/8" | 00000000 | 000000 |
1/4"-28 | 1" | 6 | 3" | 75 | 75 | 6" | -65° to 225° | 5/8" | 9 5/8" | 00000000 | 000000 |
1/4"-28 | 1" | 6 | 4" | 65 | 65 | 6" | -65° to 225° | 5/8" | 11 1/8" | 00000000 | 000000 |
1/4"-28 | 1" | 6 | 6" | 60 | 60 | 6" | -65° to 225° | 5/8" | 14 1/8" | 00000000 | 00000 |
5/16"-24 | 1 3/16" | 3 | 4" | 140 | 140 | 6" | -65° to 225° | 3/4" | 11 9/16" | 00000000 | 000000 |
5/16"-24 | 1 3/16" | 6 | 3" | 170 | 170 | 6" | -65° to 225° | 3/4" | 10 1/16" | 00000000 | 000000 |
5/16"-24 | 1 3/16" | 6 | 6" | 80 | 80 | 6" | -65° to 225° | 3/4" | 14 9/16" | 00000000 | 000000 |
3/8"-24 | 1 3/8" | 6 | 4" | 500 | 500 | 6" | -65° to 225° | 3/4" | 12 37/64" | 00000000 | 000000 |
3/8"-24 | 1 3/8" | 6 | 6" | 300 | 300 | 6" | -65° to 225° | 3/4" | 15 37/64" | 00000000 | 000000 |
Low-Friction Create-Your-Own Push/Pull Control Cables
A splined core limits contact points on the cable’s liner, so the core slides back and forth smoothly and keeps the cable from twisting. Pair these cables with a knob or lever (not included) to operate valves, throttle controls, and HVAC damper controls from a distance. They're flexible for weaving around obstructions.
Clamp-mount cables have threaded fittings on both ends and a grooved body for mounting with strap clamps or U-bolts.
Panel-mount cables are also known as bulkhead mount cables. They have threaded fittings with hex nuts and washers at each end for mounting through a panel.
Thread | Dynamic Load Cap., lbs. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | Lg. | O'all Lg., ft. | Max. Stroke Lg. | Push | Pull | Bend Radius | Temp. Range, °F | For Clamp Hole Dia. | Fitting Lg. | Each | |
Steel Cable Core with Plastic Cover | |||||||||||
10-32 | 7/8" | 4 | 3" | 40 | 50 | 8" | -40° to 210° | 7/16" | 8" | 0000000 | 0000000 |
1/4"-28 | 1" | 3 | 3" | 130 | 170 | 8" | -40° to 210° | 9/16" | 8 3/8" | 0000000 | 00000 |
1/4"-28 | 1" | 4 | 3" | 130 | 170 | 8" | -40° to 210° | 9/16" | 8 3/8" | 0000000 | 00000 |
1/4"-28 | 1" | 6 | 3" | 130 | 170 | 8" | -40° to 210° | 9/16" | 8 3/8" | 0000000 | 00000 |
1/4"-28 | 1" | 6 | 4" | 110 | 170 | 8" | -40° to 210° | 9/16" | 9 7/8" | 0000000 | 00000 |
1/4"-28 | 1" | 15 | 4" | 110 | 170 | 8" | -40° to 210° | 9/16" | 9 7/8" | 0000000 | 000000 |
Thread | Dynamic Load Cap., lbs. | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Size | Lg. | O'all Lg., ft. | Max. Stroke Lg. | Push | Pull | Bend Radius | Temp. Range, °F | For Panel Cutout Dia. | Fitting Lg. | Each | |
Steel Cable Core with Plastic Cover | |||||||||||
10-32 | 7/8" | 3 | 3" | Not Rated | Not Rated | 6" | -65° to 225° | 7/16" | 8.813" | 00000000 | 0000000 |
10-32 | 7/8" | 4 | 3" | 40 | 50 | 8" | -40° to 210° | 7/16" | 8 53/64" | 0000000 | 000000 |
10-32 | 7/8" | 6 | 3" | Not Rated | Not Rated | 6" | -65° to 225° | 7/16" | 8.813" | 00000000 | 000000 |
1/4"-28 | 1" | 3 | 3" | 130 | 170 | 8" | -40° to 210° | 5/8" | 9 25/64" | 0000000 | 00000 |
1/4"-28 | 1" | 3 | 4" | Not Rated | Not Rated | 8" | -65° to 225° | 5/8" | 10.13" | 00000000 | 00000 |
1/4"-28 | 1" | 4 | 3" | 130 | 170 | 8" | -40° to 210° | 5/8" | 9 25/64" | 0000000 | 00000 |
1/4"-28 | 1" | 4 | 4" | Not Rated | Not Rated | 8" | -65° to 225° | 5/8" | 10.13" | 00000000 | 00000 |
1/4"-28 | 1" | 6 | 2" | 150 | 170 | 8" | -40° to 210° | 5/8" | 7 57/64" | 0000000 | 00000 |
1/4"-28 | 1" | 6 | 3" | 130 | 170 | 8" | -40° to 210° | 5/8" | 9 25/64" | 0000000 | 00000 |
1/4"-28 | 1" | 6 | 4" | 110 | 170 | 8" | -40° to 210° | 5/8" | 10 57/64" | 0000000 | 00000 |
1/4"-28 | 1" | 15 | 4" | 110 | 170 | 8" | -40° to 210° | 5/8" | 10 57/64" | 00000000 | 000000 |
Dynamic Load Cap., lbs. | ||||||||
---|---|---|---|---|---|---|---|---|
For Thread Size | For Max. Stroke Lg. | Push | Pull | Length | Height | Material | Each | |
1/4"-28 | 3" | 200 | 200 | 5 3/8" | 15 1/2" | Zinc-Plated Steel | 0000000 | 000000 |
Corrosion-Resistant Create-Your-Own Push/Pull Control Cables
Well-suited for damp environments, these control cables have stainless steel fittings for excellent corrosion resistance. Pair them with a knob or lever (not included) to operate valves, throttle controls, and HVAC damper controls from a distance. They're flexible for weaving around obstructions.
Clamp-mount cables have threaded fittings on both ends and a grooved body for mounting with strap clamps or U-bolts.
Panel-mount cables are also known as bulkhead mount cables. They have threaded fittings with hex nuts and washers at each end for mounting through a panel.
Dynamic Load Cap., lbs. | ||||||||
---|---|---|---|---|---|---|---|---|
For Thread Size | For Max. Stroke Lg. | Push | Pull | Length | Height | Material | Each | |
1/4"-28 | 3" | 200 | 200 | 5 3/8" | 15 1/2" | Zinc-Plated Steel | 0000000 | 000000 |
Pull Control Cables
Similar to the brake cable on a bicycle, these cables exert pulling force so you can control components such as latches, release valves, and brakes. When you relax your pull, springs in your component pull the cable back. To connect these cables, anchor them on both ends through a panel or bulkhead using the included nuts. They have a steel core, but they’re flexible so you can weave them around obstacles and corners to connect to hard-to-reach components. Surrounding the cable is a plastic cover that stays in place as the cable slides through smoothly. The cover is durable and protects the cable from dirt and abrasion.
Once they’re connected, control these cables using a knob or handle. Some come with a knob attached, but add your own otherwise.
Cable | Thread | Knob | Panel-Mount Cables | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
OD | Core Dia. | Size | Lg. | O'all Lg., ft. | Max. Stroke Lg. | Dynamic Pull Load Cap., lbs. | Bend Radius | Material | Dia. | Temp. Range, °F | Mounting Hardware Included | For Panel Cutout Dia. | Fitting Lg. | Each | |
Steel Cable Core with Plastic Cover | |||||||||||||||
Without Knob | |||||||||||||||
0.31" | 0.080" | 10-32 | 3/4" | 5 | 2" | 350 | 6" | __ | __ | -65° to 225° | Yes | 27/64" | 7 1/4" | 00000000 | 000000 |
0.31" | 0.080" | 10-32 | 3/4" | 5 | 3" | 350 | 6" | __ | __ | -65° to 225° | Yes | 27/64" | 8 3/4" | 00000000 | 00000 |
0.31" | 0.080" | 10-32 | 3/4" | 10 | 2" | 350 | 6" | __ | __ | -65° to 225° | Yes | 27/64" | 7 1/4" | 00000000 | 00000 |
0.31" | 0.080" | 10-32 | 3/4" | 10 | 3" | 350 | 6" | __ | __ | -65° to 225° | Yes | 27/64" | 8 3/4" | 00000000 | 00000 |
0.44" | 0.093" | 1/4"-28 | 3/4" | 5 | 2" | 500 | 6" | __ | __ | -65° to 225° | Yes | 39/64" | 7 7/8" | 00000000 | 000000 |
0.44" | 0.093" | 1/4"-28 | 3/4" | 5 | 3" | 500 | 6" | __ | __ | -65° to 225° | Yes | 39/64" | 9 3/8" | 00000000 | 000000 |
0.44" | 0.093" | 1/4"-28 | 3/4" | 10 | 2" | 500 | 6" | __ | __ | -65° to 225° | Yes | 39/64" | 7 7/8" | 00000000 | 000000 |
0.44" | 0.093" | 1/4"-28 | 3/4" | 10 | 3" | 500 | 6" | __ | __ | -65° to 225° | Yes | 39/64" | 9 3/8" | 00000000 | 000000 |
With Knob | |||||||||||||||
0.44" | 0.125" | 1/4"-28 | 7/8" | 6 | 2" | 500 | 6" | Plastic | 2 1/2" | -65° to 225° | Yes | 39/64" | 9 1/8" | 00000000 | 000000 |
0.44" | 0.125" | 1/4"-28 | 7/8" | 10 | 3" | 500 | 6" | Plastic | 2 1/2" | -65° to 225° | Yes | 39/64" | 11 1/8" | 00000000 | 000000 |
Rotary Control Cables
Transmit rotary motion to operate valves, throttle controls, and HVAC damper controls. These cables are flexible, so you can weave them around obstructions to manipulate controls from a distance. They have a D-profile shaft on one end for installing a manual control knob and a set screw on the other end for securing to a shaft. Push the male end of the shaft through a panel cutout and secure with locknuts.
Cables with a plastic cover protect the core from bending. The cover also helps to prevent injury from the rotating cable.
Cables with sleeve bearings last longer than cables without them because the bearings support the connection between the coupling and core.
For technical drawings and 3-D models, click on a part number.
Maximum Torque @ | Cable | Male Fitting | Female Fitting | Panel-Mount Cables | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
12" Bend Radius, in.-lbs. | 50" Bend Radius, in.-lbs. | Overall Lg., ft. | OD | Core Dia. | Bend Radius | Shaft Dia. | For Panel Cutout Dia. | Lg. | For Shaft Dia. | Lg. | Fitting Material | Bearing Material | Temp. Range, °F | Each | |
Steel Cable Core | |||||||||||||||
7.5 | 7.5 | 1/2 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
7.5 | 7.5 | 1 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
7.5 | 7.5 | 1 1/2 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
7.5 | 7.5 | 2 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
7.5 | 7.5 | 3 | __ | 0.125" | 3" | 1/4" | 3/8" | 1 9/16" | 1/4" | 13/16" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
24 | 26 | 1 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 00000 |
24 | 26 | 1 1/2 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 2 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 3 | __ | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
Steel Cable Core with Plastic Cover | |||||||||||||||
24 | 26 | 1 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 1 1/2 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 2 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
24 | 26 | 3 | 0.38" | 0.188" | 4" | 1/4" | 3/8" | 1 9/16" | 1/4" | 7/8" | Zinc-Plated Steel | __ | 40° to 190° | 0000000 | 000000 |
Steel Cable Core with Plastic Cover and Sleeve Bearings | |||||||||||||||
24 | 26 | 3 | 0.39" | 0.188" | 4" | 1/4" | 3/8" | 2 1/2" | 1/4" | 2 7/16" | Zinc-Plated Steel | Bronze | 40° to 190° | 0000000 | 000000 |
24 | 26 | 4 | 0.39" | 0.188" | 4" | 1/4" | 3/8" | 2 1/2" | 1/4" | 2 7/16" | Zinc-Plated Steel | Bronze | 40° to 190° | 0000000 | 000000 |
24 | 26 | 6 | 0.39" | 0.188" | 4" | 1/4" | 3/8" | 2 1/2" | 1/4" | 2 7/16" | Zinc-Plated Steel | Bronze | 40° to 190° | 0000000 | 000000 |
Hose Whip Checks
OSHA compliant, these whip checks stop your hose from whipping when couplings are accidentally disconnected under pressure.
Whip checks with spring-loaded loop ends are for hose-to-hose use. The loops slip over the ends of your hose.
Whip checks with spring-loaded loop end and choker end are for hose-to-tool use. The loop goes over the hose end, and the choker goes on your tool.
Whip checks with loop ends work with the widest range of hose diameters in our offering. As the inside diameter of a compatible hose increases, the maximum pressure decreases.
Whip checks with loop end and bolt end can bolt to a surface on one end for a secure connection. They’re able to handle the high pressures of hydraulic hose.
Cable | |||||||
---|---|---|---|---|---|---|---|
For Hose ID | Dia. | Lg. | Material | For Max. Pressure, psi | Specifications Met | Each | |
1/2" - 1 1/4" | 1/8" | 20 1/4" | Steel | 200 | MSHA (Mine Safety and Health Administration) Standards, OSHA Compliant 29 CFR 1926.603 | 0000000 | 000000 |
1 1/2" - 3" | 1/4" | 38" | Steel | 200 | MSHA (Mine Safety and Health Administration) Standards, OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
4" | 3/8" | 44" | Steel | 200 | MSHA (Mine Safety and Health Administration) Standards, OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
Cable | |||||||
---|---|---|---|---|---|---|---|
For Hose ID | Dia. | Lg. | Material | For Max. Pressure, psi | Specifications Met | Each | |
1/2" - 1 1/4" | 1/8" | 20 1/4" | Steel | 200 | MSHA (Mine Safety and Health Administration) Standards, OSHA Compliant 29 CFR 1926.603 | 0000000 | 000000 |
1 1/2" - 3" | 1/4" | 38" | Steel | 200 | MSHA (Mine Safety and Health Administration) Standards, OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
4" | 3/8" | 44" | Steel | 200 | MSHA (Mine Safety and Health Administration) Standards, OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
Cable | ||||||||
---|---|---|---|---|---|---|---|---|
For Hose ID | Lg. | Wd. | Thick. | Material | For Max. Pressure (For Hose ID) | Specifications Met | Each | |
1/2" - 2" | 30" | 1" | 3/8" | Nylon Fabric | 13,000 psi (1/2") 3,300 psi (1") 750 psi (2") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 000000 |
1/2" - 2" | 30" | 1 1/8" | 1" | Nylon Fabric | 37,000 psi (1/2") 9,400 psi (1") 2,300 psi (2") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
1" - 4" | 44" | 1" | 3/8" | Nylon Fabric | 3,300 psi (1") 750 psi (2") 200 psi (4") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
1" - 4" | 44" | 1 1/8" | 1" | Nylon Fabric | 9,400 psi (1") 2,300 psi (2") 580 psi (4") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
2" - 6" | 64" | 1" | 3/8" | Nylon Fabric | 750 psi (2") 200 psi (4") 90 psi (6") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
2" - 6" | 64" | 1 1/8" | 1" | Nylon Fabric | 2,300 psi (2") 580 psi (4") 260 psi (6") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
2" - 6" | 74" | 1" | 3/8" | Nylon Fabric | 750 psi (2") 200 psi (4") 90 psi (6") | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
Cable | ||||||||
---|---|---|---|---|---|---|---|---|
For Hose ID | Lg. | Wd. | Thick. | Material | For Max. Pressure, psi | Specifications Met | Each | |
1/4" - 3/4" | 24" | 3/4" | 1/8" | Polyester Fabric | 7,250 | OSHA Compliant 29 CFR 1926.603 | 0000000 | 000000 |
3/4" - 1 1/2" | 11 1/2" | 3/4" | 1/8" | Polyester Fabric | 7,250 | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |
1 1/2" - 2" | 18 1/2" | 3/4" | 1/8" | Polyester Fabric | 7,250 | OSHA Compliant 29 CFR 1926.603 | 0000000 | 00000 |