About Heaters for Pipes and Tubes
Self-Regulating Heat Cable—Adjusts its heat output in response to surface as well as surrounding temperatures.
Constant-Wattage Heat Cable—Always puts out the designated amount of watts/ft., regardless of the surrounding temperature.
More
Sensor Signal Converter Cords


Send data between sensors and receivers that have different signal types. These cords change the output signal from PNP to NPN. They connect your sensor to equipment with an M12 connection. Since they’re A coded, these cords work with most AC and DC systems. They’re also used to connect sensors to IO Link controllers and within fieldbus systems, such as Profibus and DeviceNet.
These cords were designed with tough industrial applications in mind. Insulated with polyurethane, they bend easily without cracking, and they won’t break down from oil or coolants. They’re IP rated to block out water if briefly submerged or sprayed during high-pressure washdowns. With a 90° elbow socket, these cords sit flush against equipment, so they fit behind machinery and in other tight spaces. The socket has internal threads that keep it from shaking loose due to vibration.
To determine the signal output of your sensor, use a tester (not included).
For technical drawings and 3-D models, click on a part number.
Signal Type | Socket | Cord | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switch Starting Position | No. of Poles | Input | Output | Housing Thread Size | Face Dia. | Lg., ft. | Current, A | Voltage | Wire Ga. | OD | Insulation Material | Temp. Range, °F | Environmental Rating | Specifications Met | Color | Each | |
90° Elbow Socket (Internal Thread) × Wire Leads | |||||||||||||||||
A-Coded—Unshielded | |||||||||||||||||
1 Off (Normally Open) | 5 | PNP | NPN | M12 | 0.3" | 16 | 0.1 | 24V DC | 22 | 0.43" | Polyurethane Rubber | -10° to 140° | IP65, IP68, IP69K | CE Marked | Black | 0000000 | 000000 |
1 On (Normally Closed) | 5 | PNP | NPN | M12 | 0.3" | 16 | 0.1 | 24V DC | 22 | 0.43" | Polyurethane Rubber | -10° to 140° | IP65, IP68, IP69K | CE Marked | Black | 0000000 | 00000 |
Detachable-Cord AC to DC Adapters










Couple these adapters with a cord that matches your outlet and length requirements to run DC-powered electronics. Instead of plugging directly into an outlet, the body of these adapters sits on the floor or other surface, so it remains out of the way and won’t block multiple outlets. These adapters use switching regulation—they produce the stated voltage even when your outlet’s power or the power drawn by your device fluctuates. Most have an LPS low-voltage output, so if something fails inside these adapters, they’ll limit the risk of electrical shocks. They meet U.S., Canadian, and European safety standards. Many also meet U.S. and European standards for energy efficiency.
When choosing an adapter, match the output voltage and polarity of your device. Look for the polarity illustration on your device or the adapter you're replacing. The current you choose should, at a minimum, match your device. You can choose a higher current, but it will not improve performance.
Adapters with an IEC C8 input require power cords with a C7 socket. With Class II shock protection, they have two levels of insulation that prevent electrical shocks.
Adapters with an IEC C14 input require power cords with a C13 socket. They have Class I shock protection and prevent electrical shocks with a combination of insulation and a protective ground.
Barrel/Pin Output Connection | Straight-Blade Input Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Polarity | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Shock Protection Class | Protections Provided | Color | Each | |
IEC C8 Input × Barrel Output | ||||||||||||||
24V DC | 0.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.48 | Straight | 5 | II | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | II | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 2.71 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | II | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × Barrel Output | ||||||||||||||
24V DC | 0.8 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.48 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 1.5 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 2.71 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.4 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 3.75 | Positive | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 1.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
IEC C14 Input × 4-Pin Circular DIN Output | ||||||||||||||
24V DC | 6.6 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.2 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 00000 |
24V DC | 8.3 | __ | __ | __ | Straight | 120V AC, 240V AC | 2.8 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
IEC C14 Input × 6-Pin Molex Mini-Fit Output | ||||||||||||||
24V DC | 12.5 | __ | __ | __ | Straight | 120V AC, 240V AC | 3.9 | Straight | 5 | I | Overcurrent, Overvoltage, Short Circuit | Black | 00000000 | 000000 |
AC to DC Adapter Cords




Plug these adapter cords into a standard outlet and they change AC voltage to DC voltage. These cords use switching regulation, so they produce the stated voltage even when your outlet’s power or the power drawn by your device fluctuates. It also means they won’t get too hot. They have an LPS low-voltage output and Class II shock protection, so if something fails inside these cords, they’ll limit the risk of electrical shocks. These cords meet U.S. and Canadian safety standards as well as U.S. DOE (Department of Energy) Level VI standards for energy efficiency.
When choosing an adapter, match the output voltage and polarity of your device. Look for the polarity illustration on your device or the adapter you're replacing. The current you choose should, at a minimum, match your device. You can choose a higher current, but it will not improve performance.
Barrel Output Connection | Straight-Blade Input Connection | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | NEMA Style | End Shape | Lg., ft. | Protections Provided | Specifications Met | Each | |
Negative Polarity | |||||||||||||
24V DC | 0.5 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 00000000 | 000000 |
24V DC | 0.5 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 0.75 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 0.75 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 00000000 | 00000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 1.5 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | UL Listed, C-UL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 1.5 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | UL Listed, C-UL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
Positive Polarity | |||||||||||||
24V DC | 0.5 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 00000000 | 00000 |
24V DC | 0.5 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 0.4 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 0.75 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 0.75 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 0.5 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 00000000 | 00000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 0.8 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | ETL Listed, C-ETL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 1.5 | 2.1 | 5.5 | Straight | 120V AC 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | UL Listed, C-UL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
24V DC | 1.5 | 2.5 | 5.5 | Straight | 120V AC 240V AC | 1 | 1-15 | 90° Elbow | 6 | Overvoltage, Short Circuit | UL Listed, C-UL Listed, DOE Level VI Efficiency | 000000000 | 00000 |
Medical-Grade AC to DC Adapters










To run DC-powered lab and medical equipment from your outlet, add a power cord with the plug style and length you need. These adapters meet strict IEC, UL, or ANSI/AAMI standards for use with medical devices. They also have a Means of Protection rating of 2xMOPP, which is the highest level of shock protection available for medical-grade power supplies, so in addition to using them with lab and medical equipment, you can use them with devices that come into contact with patients.
Unlike adapters with bodies that plug directly into an outlet, the body of these adapters rests on a desk or the floor, so it won’t block multiple outlets. Adapters with an IEC C8 input connection require power cords with a C7 socket. Those with an IEC C14 input connection require power cords with a C13 socket.
When selecting an adapter, make sure the DC voltage and amps for the pin output connection can handle the requirements of your device. Choosing a DC voltage and amps that are much higher than you need will not improve performance.
These adapters use switching regulation, which means they produce the stated voltage despite fluctuations in your outlet’s power and the power being drawn by your device. It also means they won’t get too hot.
If you exceed the maximum voltage or load, these adapters shut down to protect both the adapters and the connected equipment.
All of these adapters meet European safety standards. Adapters with Class II shock protection have two levels of insulation to prevent electrical shocks. Those with Class I shock protection prevent electrical shocks with a combination of insulation and a protective ground.
Barrel/Pin Output Connection | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | Polarity | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Shock Protection Class | Protections Provided | Specifications Met | Color | Each | |
Nondetachable-Cord | |||||||||||||
IEC C8 Input × 4-Pole 4-Pin Circular DIN Output | |||||||||||||
24V DC | 2.7 | Positive | Straight | 120V AC, 240V AC | 2 | Straight | 3.4 | II | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, ANSI/AAMI ES60601-1, UL/CSA/IEC/EN 60601-1 | Black | 0000000 | 000000 |
IEC C14 Input × 4-Pole 4-Pin Circular DIN Output | |||||||||||||
24V DC | 2.7 | Positive | Straight | 120V AC, 240V AC | 2 | Straight | 3.4 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, ANSI/AAMI ES60601-1, UL/CSA/IEC/EN 60601-1 | Black | 0000000 | 00000 |
24V DC | 6.9 | Positive | Straight | 120V AC, 240V AC | 2.5 | Straight | 3.44 | I | Overvoltage, Short Circuit | CE Marked, UL60601-1, EN60601-1, IEC60601-1 | Black | 0000000 | 000000 |
IEC C14 Input × 6-Pole Molex Mini-Fit Output | |||||||||||||
24V DC | 10.4 | Positive | Straight | 120V AC, 240V AC | 1.3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1 | Black | 0000000 | 000000 |
IEC C14 Input × 10-Pole Molex Mini-Fit Output | |||||||||||||
24V DC | 12.5 | Positive | Straight | 120V AC, 240V AC | 3 | Straight | 2.62 | I | Overload, Overvoltage, Overtemp, Short Circuit | CE Marked, 60950-1, IEC/ES/CSA/EN60601-1, IEC/UL/CSA/EN62368-1, IEC60601-1-11 | Black | 0000000 | 000000 |
International AC to DC Adapter Cords







Swap the plug to match the outlet of the region you’re in instead of using separate cords for each country. These adapter cords convert AC voltage to power DC electronics. Designed with switching regulation, they maintain consistent voltage during power fluctuations and don’t get too hot. They meet U.S., Canadian, European, Australian, New Zealand, and Chinese safety standards.
A limited power source (LPS) low-voltage output decreases the risk of electric shock if something fails inside these cords. Class II shock protection means they have two levels of insulation. These cords meet U.S. DOE (Department of Energy) Level VI standards for energy efficiency when they're in-use, as well as when they're plugged in but not in use.
Choose an adapter cord with an output voltage that matches the voltage of your device. The polarity of the adapter cord and your device must also be the same. Look for the polarity illustration on your device or the adapter cord you’re replacing and pick a cord to match.
Barrel Output Connection | Straight-Blade Input Connection | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Voltage | Current, A | End ID, mm | End OD, mm | End Shape | Voltage | Current, A | End Shape | Lg., ft. | Protections Provided | Color | Each | |
Negative Polarity | ||||||||||||
AS 3112, BS 1363, CEE 7/16, × NEMA 1-15 Plugs | ||||||||||||
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 000000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 00000 |
Positive Polarity | ||||||||||||
AS 3112, BS 1363, CEE 7/16, × NEMA 1-15 Plugs | ||||||||||||
24V DC | 1 | 2.1 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 00000 |
24V DC | 1 | 2.5 | 5.5 | Straight | 120V AC, 240V AC | 0.8 | 90° Elbow | 5 | Overvoltage, Short Circuit | Black | 0000000 | 00000 |
Solenoid Valve Cords
Use these cords with hydraulic and air-powered valves, motors, pumps, and pressure switches. They have a solenoid valve socket on one end and an M12 threaded plug on the other. The ground connection is not included in the number of poles. A power-indicating light on the socket illuminates when the cord has power. All are IP-rated for protection from washdowns and temporary submersion.
For technical drawings and 3-D models, click on a part number.

Socket | Plug | Cord | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DIN Type | Contact Distance | Housing Thread Size | Coding | No. of Poles | No. of Ground Connections | Lg., ft. | Wire Gauge | Current, A | Voltage | OD | Insulation Material | Environmental Rating | Specifications Met | Each | |
90° Elbow Socket × Plug (External Thread) | |||||||||||||||
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 000000 |
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type A | 0.71" (18 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type BI | 0.43" (11 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type C | 0.31" (8 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 1 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 00000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 3 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |
Type CI | 0.37" (9.4 mm) | M12 | A | 2 | 1 | 6 1/2 | 18 | 4 | 24V AC/24V DC | 0.23" | PVC Plastic | IP67, IP66K | CSA Certified, CE Marked, CSA-US Certified, DIN 43650 | 0000000 | 00000 |

For Thread Size | Material | Includes | Each | |
For Plugs | ||||
---|---|---|---|---|
M12 | Anodized Aluminum | Lanyard | 0000000 | 000000 |
Distribution Blocks for Nano M8 and Micro M12 Cords




Connect multiple devices to these distribution blocks to create a network between equipment. They’re rated IP67 for protection from dust and submersion and IP65 for protection from low-pressure washdown.
Socket | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Signal Output Type | Housing Thread Size | No. of Outlets | No. of Poles | Coding | Face Dia. | Cord Lg., ft. | Current, A | Voltage | Wire Gauge | Cord OD | Environmental Rating | Specifications Met | Temp. Range, °F | Color | Each | |
Socket (Internal Thread) with Wire Leads | ||||||||||||||||
PNP | M8 | 4 | 3 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.27" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 0000000 |
PNP | M8 | 4 | 3 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.27" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | __ | 0.2" | 16 | 2 | 24V DC | 22 | 0.34" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M8 | 8 | 3 | __ | 0.2" | 32 | 2 | 24V DC | 22 | 0.34" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 175° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.33" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 4 | 4 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.33" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | A | 0.3" | 16 | 4 | 24V DC | 22 | 0.36" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
PNP | M12 | 8 | 4 | A | 0.3" | 32 | 4 | 24V DC | 22 | 0.36" | IP65, IP67 | UL Listed, C-UL Listed | 0° to 155° | Gray | 000000 | 000000 |
Solenoid Valve Connectors
Connect hydraulic and air-powered valves, motors, pumps, and pressure switches.
IP67 rated connectors protect against temporary submersion.
For technical drawings and 3-D models, click on a part number.


Number of Poles | Current | Wire Lead Gauge | Cable Orientation | Cable Lead Lg., ft. | Color | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24V AC/24V DC | |||||||||||||
2 | 10A | 18 | __ | 6 | Gray | 1.09" | 1.05" | 1.94" | Power-Indicating Light | 175° | IP67 | 0000000 | 000000 |
2 | 10A | 18 | __ | 16 | Gray | 1.09" | 1.05" | 1.94" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
Type BI—0.43" (11 mm) Contact Distance | |||||||||||||
24V AC/24V DC | |||||||||||||
2 | 4A | 18 | With Ground Terminal | 6.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 18 | With Ground Terminal | 16.5 | Black | 0.85" | 1.2" | 1.77" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
Type C—0.31" (8 mm) Contact Distance | |||||||||||||
24V AC/24V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 185° | IP67 | 0000000 | 00000 |
2 | 4A | 18 | __ | 16.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
2 | 4A | 20 | __ | 6 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
2 | 4A | 20 | __ | 16 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
Type CI—0.37" (9.4 mm) Contact Distance | |||||||||||||
24V AC/24V DC | |||||||||||||
2 | 4A | 18 | __ | 6.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 18 | __ | 16.5 | Black | 0.61" | 0.98" | 1.4" | Power-Indicating Light | 158° | IP67 | 00000000 | 00000 |
2 | 4A | 20 | __ | 6 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |
2 | 4A | 20 | __ | 16 | Gray | 0.59" | 1" | 1.42" | Power-Indicating Light | 175° | IP67 | 0000000 | 00000 |


Length | Width | Height | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Current | Wire Lead Gauge | Cable Lead Lg., ft. | Center-to-Center Connector Lg. | Color | A | B | A | B | A | B | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | ||||||||||||||||
24V AC/24V DC | ||||||||||||||||
3 | 4A | 18 | 16.5 | 4.3" | Black | 1.06" | 1.06" | 1.18" | 1.18" | 1.06" | 1.71" | Power-Indicating Light | 185° | IP67 | 00000000 | 000000 |
3 | 4A | 18 | 16.5 | 5.9" | Black | 1.06" | 1.06" | 1.18" | 1.18" | 1.06" | 1.71" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |


Number of Poles | Current | For Wire Gauge | Wire Lead Gauge | Cable Orientation | Cable Lead Lg., ft. | Terminal Connection Type | Color | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type B—0.39" (10 mm) Contact Distance | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24V AC/24V DC | |||||||||||||||
3 | 4A | 18 | 18 | Opposite Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 000000 |
3 | 4A | 18 | 18 | Opposite Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
Type BI—0.43" (11 mm) Contact Distance | |||||||||||||||
24V AC/24V DC | |||||||||||||||
3 | 4A | 18 | 18 | Opposite Ground Terminal | 6.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | Opposite Ground Terminal | 16.5 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 10 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
3 | 4A | 18 | 18 | With Ground Terminal | 33 | Solder | Gray | 1.77" | 0.85" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |


Number of Poles | Current | For Wire Gauge | Wire Lead Gauge | Cable Lead Lg., ft. | Terminal Connection Type | Color | Lg. | Wd. | Ht. | Features | Max. Temp., °F | Environmental Rating | Each | |
Type A—0.71" (18 mm) Contact Distance | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
24V AC/24V DC | ||||||||||||||
3 | 4A | 18 | 18 | 10 | Solder | Gray | 1.77" | 1.06" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 000000 |
3 | 4A | 18 | 18 | 33 | Solder | Gray | 1.77" | 1.06" | 1.18" | Power-Indicating Light | 185° | IP67 | 00000000 | 00000 |
Electrical Connectors for Schunk Grippers


Change the M8 8-pin connection on your Schunk gripper to wire leads for hardwiring robots that don’t have an M8 8-pin connection.
For technical drawings and 3-D models, click on a part number.
Housing | ||||||||
---|---|---|---|---|---|---|---|---|
Number of Poles | Number of Wire Leads | Voltage | Color | Cable Lead Lg., m | Thread Size | Thread Type | Each | |
Sockets with Wire Leads—Internal Thread | ||||||||
8 | 8 | 24V DC | Black | 5 | M8 × 1 mm | Metric | 00000000 | 000000 |
Ultra-Flexible Constant-Wattage Heaters for Pipes and Tubes
Wrap the flexible heating element around small-diameter pipes and tubes or pack it into tight spaces. These heaters maintain a consistent heat output along the entire length of the cable, regardless of the environmental temperature. All require a temperature switch or controller to regulate heat output. They do not produce an electromagnetic field, so they can be used near electronics.
Pair heaters with a 2.1 mm ID barrel connector with an AC adapter (not included) to power them from a standard AC wall outlet.
Note: Only install these heaters in accessible locations; do not install them behind walls, underground, or in other difficult-to-access areas. Use fiberglass tape or heat-transfer putty to install them directly on surfaces that are free of dirt, grease, and rough edges. Do not use electrical tape, duct tape, metal bands, or wire. To prevent heat loss and protect heaters from moisture and corrosion, wrap them with fiberglass insulation.

Lg., ft. | Wattage, W | Watt Density | Current, A | Wd. | Thick. | Environment Temp. Range, °F | Cable Cover Material | For Surface Material | Each | |
24V DC | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
2 | 6 | 3W/ft. | 0.3 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 000000 |
4 | 12 | 3W/ft. | 0.5 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 00000 |
6 | 18 | 3W/ft. | 0.8 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 00000 |
8 | 24 | 3W/ft. | 1 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 00000 |


Heaters | AC Adapters | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Lg., ft. | Wattage, W | Watt Density, W/ft. | Current, A | Wd. | Thick. | Environment Temp. Range, °F | Cable Cover Material | For Surface Material | Each | Each | ||
24V DC | ||||||||||||
2 | 6 | 3 | 0.3 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 000000 | 00000000 | 000000 |
4 | 12 | 3 | 0.5 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 00000 | 00000000 | 00000 |
6 | 18 | 3 | 0.8 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 00000 | 00000000 | 00000 |
8 | 24 | 3 | 1 | 0.12" | 0.06" | -30° to 220° | Polymer-Based Fiber | Metal, Plastic | 0000000 | 00000 | 00000000 | 00000 |